1.
Phys Med Biol ; 65(19): 195014, 2020 09 30.
Article in English | MEDLINE | ID: mdl-32155606

ABSTRACT

Magnetic particle imaging (MPI) is a new medical imaging technique visualizing the concentration distribution of superparamagnetic nanoparticles used as tracer material. MPI is not yet in clinical routine, since one of the challenges is the upscaling of scanners. Typically, the magnetic fields of MPI scanners are generated electromagnetically, resulting in an immense power consumption but providing high flexibility in terms of adjusting the field strengths and very fast image acquisition rates. Permanent magnets provide high flux densities and do not need any power supply. However, the flux density is not adjustable, and a mechanical movement is slow compared to electromagnetically varying fields. The MPI scanner concept proposed here uses permanent magnets and provides high flexibility, with the possibility to choose between fast overview scanning and detailed image acquisition. By mechanical rotation of magnetic rings in Halbach array configuration, it is possible to adjust the field or gradient strengths. The latter allows for determining the spatial resolution and the size of the field of view. A continuous mechanical rotation defines the coarseness of the scanning trajectory and image acquisition rate. This concept provides a comparable flexibility, as an alternating magnetic field and an adjustable field gradient can be applied as known from electromagnetically driven MPI systems, and therefore yields high potential for an enlarged system. We present the idea of an arrangement of Halbach arrays and how to calculate the generated magnetic fields. Simulations for an exemplary geometry are provided to show the potential of the proposed setup.


Subject(s)
Image Processing, Computer-Assisted/instrumentation , Image Processing, Computer-Assisted/methods , Magnetite Nanoparticles/chemistry , Phantoms, Imaging , Electromagnetic Fields , Humans
2.
Phys Med Biol ; 62(16): 6708-6728, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28636564

ABSTRACT

The aim of this work was to determine magnetic field correction factors that are needed for dosimetry in hybrid devices for MR-guided radiotherapy for Farmer-type ionization chambers for different magnetic field strengths and field orientations. The response of six custom-built Farmer-type chambers irradiated at a 6 MV linac was measured in a water tank positioned in a magnet with magnetic field strengths between 0.0 T and 1.1 T. Chamber axis, beam and magnetic field were perpendicular to each other and both magnetic field directions were investigated. EGSnrc Monte Carlo simulations were compared to the measurements and simulations with different field orientations were performed. For all geometries, magnetic field correction factors, [Formula: see text], and perturbation factors were calculated. A maximum increase of 8.8% in chamber response was measured for the magnetic field perpendicular to chamber and beam axis. The measured chamber response could be reproduced by adjusting the dead volume layer near the chamber stem in the Monte Carlo simulations. For the magnetic field parallel to the chamber axis or parallel to the beam, the simulated response increased by 1.1% at maximum for field strengths up to 1.1 T. A complex dependence of the response was found on chamber radius, magnetic field strength and orientation of beam, chamber axis and magnetic field direction. Especially for magnetic fields perpendicular to beam and chamber axis, the exact sensitive volume has to be considered in the simulations. To minimize magnetic field correction factors and the influence of dead volumes on the response of Farmer chambers, a measurement set-up with the magnetic field parallel to the chamber axis or parallel to the beam is recommended for dosimetry.


Subject(s)
Magnetic Fields , Radiometry/instrumentation , Monte Carlo Method , Particle Accelerators , Surgery, Computer-Assisted , Water