Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Ergonomics ; 66(5): 676-689, 2023 May.
Article in English | MEDLINE | ID: mdl-35959644

ABSTRACT

The aim of this review was to develop a test method for the evaluation of heat strain for structural firefighters wearing personal protective equipment (PPE) in Japan. We analysed a series of our laboratory's questionnaires and experimental studies and reviewed international standards on test methods. We investigated the actual average working conditions (total firefighting time on one incidence, working time with full PPE, maximum temperature and humidity during firefighting) at structural firefighting site in Japan by conducting a large-scale questionnaire survey of Japanese firefighters. We discussed test subjects (firefighters vs. non-firefighters; body size; physical fitness), exercise intensity (absolutes vs. relative; light vs. heavy) and duration, experimental temperature and relative humidity, experimental clothing items including station uniforms (shorts vs. long), and measurement variables (physiological and subjective responses), and suggested a standard test method to evaluate the heat strain of firefighters in hot and humid environments.Practitioner summary: We reviewed studies on human wear trials of firefighting personal protective equipment (PPE) in hot environments and suggested a standard test method to evaluate the heat strain of firefighters. The test method can be internationally utilised to examine the comfort functions and heat stress of PPE in hot, humid environments.


Subject(s)
Firefighters , Heat Stress Disorders , Personal Protective Equipment , Humans , Body Temperature , East Asian People , Heat Stress Disorders/diagnosis , Heat Stress Disorders/etiology , Heat Stress Disorders/prevention & control , Hot Temperature/adverse effects , Personal Protective Equipment/adverse effects , Protective Clothing/adverse effects , Temperature , Japan , Surveys and Questionnaires
2.
Appl Ergon ; 45(4): 1019-27, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24462474

ABSTRACT

The aims of this study were 1) to evaluate the current pilot test method and ascertain reliable measurements for a standard test method of mobility with personal protective equipment (PPE), such as physical performance and balance ability tests; 2) to compare two participant groups (firefighters versus non-firefighters) and to investigate whether non-firefighters are appropriate as a standard participant group in the field of PPE or not. Totally, 18 participants (nine professional firefighters and nine untrained males) performed the current pilot test method consisting of a balance test, completed prior to and after a performance test. Significant differences were found between PPE conditions and CON (the control clothing ensemble: T-shirt, shorts, and running shoes) for the functional balance test, physical performance test, heart rate, and subjective evaluations in firefighters group. Therefore, the present pilot test method is valid as a standard test method for assessing mobility while wearing PPE. Moreover, the present result shows that firefighters are more reliable than non-firefighters in testing of PPE with current test methods.


Subject(s)
Firefighters , Movement , Protective Clothing/standards , Adult , Hand Strength , Heart Rate , Humans , Male , Physical Fitness , Postural Balance , Protective Clothing/adverse effects
3.
J Occup Environ Hyg ; 10(7): 397-407, 2013.
Article in English | MEDLINE | ID: mdl-23668854

ABSTRACT

This study investigated the effects of firefighter personal protective equipment (PPE) on the determination of maximal oxygen uptake (VO(2max)) while using two different treadmill protocols: a progressive incline protocol (PIP) and a progressive speed protocol (PSP), with three clothing conditions (Light-light clothing; Boots-PPE with rubber boots; Shoes-PPE with running shoes). Bruce protocol with Light was performed for a reference test. Results showed there was no difference in VO(2max) between Bruce Light, PIP Light, and PSP Light. However, VO(2max) was reduced in Boots and Shoes with shortened maximal performance time (7 and 6 min reduced for PIP Boots and Shoes, respectively; 11 and 9 min reduced for PSP Boots and Shoes, respectively), whereas the increasing rate of VO(2) in Boots and Shoes during submaximal exercise was greater compared with Light. Wearing firefighter boots compared with wearing running shoes also significantly affected submaximal VO(2) but not VO(2max). These results suggest that firefighters' maximal performance determined from a typical VO(2max) test without wearing PPE may overestimate the actual performance capability of firefighters wearing PPE.


Subject(s)
Firefighters , Oxygen Consumption , Protective Devices , Adult , Exercise Test , Heart Rate , Humans , Lactic Acid/blood , Male , Occupational Exposure , Physical Endurance , Physical Exertion
4.
Ergonomics ; 55(7): 782-91, 2012.
Article in English | MEDLINE | ID: mdl-22506725

ABSTRACT

To examine the effects of firefighters' self-contained breathing apparatus' (SCBA) weight and its harness design on the physiological and subjective responses, eight male students performed treadmill exercise under four conditions: the 8 kg firefighter protective clothing (PC) (Control), the PC + an 11 kg SCBA with an old harness (Test A), the PC + a 6.4 kg SCBA with an old harness (Test B) and the PC + a 6.4 kg SCBA with a new harness (Test C), at ambient temperatures (T(a)) of 22°C and 32°C. Besides highlighting the fact that a heavy SCBA had a significant effect on the oxygen consumption and metabolic rate, this experiment also found that in a T(a) of 32°C, in particular, the combined effect of 4.7 kg lighter SCBA and new harness design could reduce metabolic rate and improved subjective muscle fatigue and thermal discomfort. PRACTITIONER SUMMARY: An effort to alleviate the physiological and subjective burden of firefighters by reducing the weight of SCBA and by using the new harness design has provided satisfactory results in reduced oxygen consumption and in improved subjective responses in a hot air environment.


Subject(s)
Ergonomics/instrumentation , Firefighters , Occupational Health , Respiration , Respiratory Protective Devices , Analysis of Variance , Body Temperature/physiology , Exercise Test , Heart Rate , Humans , Male , Oxygen Consumption/physiology , Young Adult
5.
Int J Biometeorol ; 56(6): 1055-64, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22290685

ABSTRACT

The purpose of this study was to explore whether there is evidence of heat acclimatization in the words used to express thermal sensation. A total of 458 urban Japanese and 601 Indonesians participated in a questionnaire. In addition, in a preliminary survey, 39 native English speakers in the UK participated. Our results showed that (1) for Indonesians, the closest thermal descriptor of a feeling of thermal comfort was 'cool' (75%) followed by 'slightly cool' (7%), 'slightly cold' (5%) and 'cold' (5%), while Japanese responses were distributed uniformly among descriptors 'cool', 'slightly cool', 'neither', 'slightly warm', and 'warm'; (2) the closest thermal descriptors of a feeling of discomfort for Indonesians were less affected by individual thermal susceptibility (vulnerability) than those for Japanese; (3) in the cases where 'cool' and 'slightly cold' were imagined in the mind, the descriptors were cognized as a thermal comfortable feeling by 97% and 57% of Indonesians, respectively; (4) the most frequently voted choice endorsing hot weather was 'higher than 32°C' for Indonesians and 'higher than 29°C' for Japanese respondents; for cold weather, 'lower than 15°C' for Japanese and 'lower than 20°C' for Indonesians. In summary, the descriptor 'cool' in Indonesians connotes a thermally comfortable feeling, but the inter-zone between hot and cold weather that was judged in the mind showed a upward shift when compared to that of Japanese. It is suggested that linguistic heat acclimatization exists on a cognitive level for Indonesians and is preserved in the words of thermal descriptors.


Subject(s)
Acclimatization/physiology , Body Temperature Regulation/physiology , Language , Semantics , Temperature , Thermosensing/physiology , Female , Humans , Indonesia , Japan , Male , Surveys and Questionnaires , United Kingdom , Young Adult
6.
Eur J Appl Physiol ; 112(6): 2171-83, 2012 Jun.
Article in English | MEDLINE | ID: mdl-21964942

ABSTRACT

The purpose of this study was to investigate the influences of menthol application according to the amount of surface area on physiological and psychological heat strains, along with body regional influences. Male students underwent two stages of experiments: [Experiment 1] Cutaneous thermal threshold test at rest on eight body regions with/without a 0.8% menthol application at T (a) 28°C and 50% RH; [Experiment 2] Six exercise tests with/without a 0.8% menthol spray at T (a) 28°C and 40% RH, while wearing firefighter's protective clothing (No menthol, PC(NO); Face and neck menthol, PC(FN); Upper body menthol, PC(UP); Whole body menthol application, PC(WB)) or wearing normal clothing (No menthol, NC(NO); Upper body menthol, NC(UP)). Experiment 1 showed that menthol caused no significant influence on cutaneous warm thresholds, while menthol applications evoked earlier detection of cool sensations, especially on the chest (P = 0.043). Experiment 2 revealed that NC(UP), PC(UP) and PC(WB) caused lower mean skin temperature, especially with higher peripheral vasoconstrictions on the extremities at rest. During exercise, NC(UP), PC(UP) and PC(WB) induced greater and earlier increases in rectal temperatures (T (re)) and a delayed sweat response, but lessened psychological burdens (P < 0.05). Both physiological and psychological effects of PC(FN) were insignificant. For a composite analysis, individual Menthol Sensitivity Index at cooling in Experiment 1 had significant relationships with the threshold for T (re) increase and changes in heart rate in NC(UP) of Experiment 2 (P < 0.05). Our results indicate that menthol's topical influence is body region-dependent, as well as depending on the exposed body surface area.


Subject(s)
Body Temperature Regulation/drug effects , Menthol/administration & dosage , Physical Exertion/drug effects , Protective Clothing , Sensation/drug effects , Skin Temperature/drug effects , Sweating/drug effects , Adult , Body Surface Area , Body Temperature Regulation/physiology , Cold Temperature , Firefighters , Heart Rate/drug effects , Heart Rate/physiology , Hot Temperature , Humans , Male , Physical Exertion/physiology , Rest/physiology , Sensation/physiology , Skin Temperature/physiology , Sweating/physiology , Vasoconstriction/drug effects , Vasoconstriction/physiology , Young Adult
7.
Ind Health ; 49(6): 714-25, 2011.
Article in English | MEDLINE | ID: mdl-22020015

ABSTRACT

The purpose of this study was to investigate the validity of infrared tympanic temperature (IR T(ty)) as a thermal index to evaluate the heat strain of workers in hot environments, in comparison with rectal temperatures at various depths (T(re-4, -8, and -16) for 4, 8 and 16 cm from the anal sphincter). Eight males underwent twelve experimental conditions: two activities (rest and exercise) × three clothing levels [Control, HDPE (high-density polyethylene coverall) and PVC (polyvinyl chloride coverall) condition] × two air temperatures (25 and 32℃ with 50%RH). The results showed that 1) in the conditions with most heat strain (HDPE or PVC condition at 32℃), IR T(ty) was equal to or even higher than T(re); 2) during exercise, physiological strain index (PSI) using IR T(ty) did not underestimate PSI-values using T(re-16), and overestimated those PSI-values from T(re-16) in HDPE and PVC conditions at 32℃; 3) during exercise, the relationships between IR T(ty) and heart and total sweat rate were stronger than those between T(re-16) and heart and total sweat rate. These results indicated that IR T(ty) is valid as a thermal index to evaluate the heat strain of workers wearing impermeable protective coveralls in hot environments. However, the application of IR T(ty) is limited only for strenuous works wearing encapsulated personal protective clothing with a hood in heat.


Subject(s)
Heat Stress Disorders/diagnosis , Hot Temperature , Infrared Rays , Protective Clothing , Thermometers/standards , Tympanic Membrane/physiology , Adult , Body Temperature Regulation/physiology , Humans , Male , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...