Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Surf Coat Technol ; 409: 126873, 2021 Mar 15.
Article in English | MEDLINE | ID: mdl-33814662

ABSTRACT

The widespread of viral airborne diseases is becoming a critical problem for human health and safety, not only for the common cold and flu, but also considering more serious infection as the current pandemic COVID-19. Even if the current heating, ventilating and air conditioning (HVAC) systems limit the disease transmission by air, the air filters are susceptible to microbial colonization. In addition, viruses spread via droplets (aerosol) produced by direct or indirect contact with infected people. In this context, the necessity of an efficient HVAC system, able to capture and inactivate viruses- and bacteria-rich aerosols, thus preserving a safe indoor air environment and protecting people, is of enormous importance. The aim of this work is the assessment of the antiviral properties of a silver nanoclusters/silica composite coating deposited via co-sputtering technique on glass, on metallic fibre-based air filters as well as on cotton textiles. The selected human respiratory viruses are: respiratory syncytial virus (RSV), the human rhinovirus (HRV) and the influenza virus type A (FluVA). The coated air filters show that the nanostructured coating develops a strong virucidal activity against RSV and FluVA, but not against the HRV.

2.
Mater Sci Eng C Mater Biol Appl ; 32(7): 1868-1877, 2012 Oct 01.
Article in English | MEDLINE | ID: mdl-34062668

ABSTRACT

The cobalt-chromium-molybdenum alloys are characterized by a high resistance to wear and corrosion, as well as good mechanical properties, allowing their use in the substitution of hip and knee joints. Five alloys were used as substrates for a coating deposition by a thermal treatment in molten salts, as reported elsewhere, in order to form a tantalum-rich coating on the sample surface, able to improve the biocompatibility and wear resistance of the materials. However, the temperature (970°C), reached during this process, is considered critical for the phase transformation of the Co-based alloys. The aim of this work is the evaluation of the temperature effects on the structure, microstructure, mechanical and tribological properties of the considered substrates, after the removal of the coating by polishing. The substrates are characterized through X-ray diffraction (XRD), scanning electron microscopy with energy dispersion spectrometry (SEM-EDS) and profilometry. The mechanical behavior is evaluated by the macro- and micro-hardness and bending tests, whereas the tribological properties are analyzed through a ball on disc test. A comparison between the as-received alloys and thermal treated substrates is reported. The biocompatibility feature is not reported in this work. The substrate crystalline structure changed during the heat treatment, inducing the formation of the hexagonal cobalt phase and the decrement of the cubic one. This crystallographic modification does not seem to influence the tribological behavior of the substrates. On the contrary, it affects the strength and ductility of the substrates.

3.
J Nanosci Nanotechnol ; 11(10): 8994-9002, 2011 Oct.
Article in English | MEDLINE | ID: mdl-22400292

ABSTRACT

Cobalt-chromium-molybdenum alloys with high carbon content (HC-CoCrMo) are widely used as materials for arthroprosthesis, in particular in metal-on-metal (MoM) hip joints. In spite of their good wear and corrosion resistance, production of metallic wear particles and metal ion release will occur on a large time-scale. An enhancement of the metal ion level in the patient's blood and urine is often reported in clinical data. Hypersensitivity, inflammatory response and cell necrosis can occur as consequence. So implants on young patients and women on childbearing age are not so widespread. The aim of this research is the realization of a thin film coating in order to improve the biocompatibility of Co-based alloys and to reduce debris production, ion release and citotoxicity. The innovative process consists of a thermal treatment in molten salts, in order to obtain a tantalum enriched thin film coating. Tantalum is chosen because it is considered a biocompatible metal with high corrosion resistance and low ion release. Three HC-CoCrMo alloys, produced by different manufacturing processes, are tested as substrates. The coating is a thin film of TaC or it can be composed by a multilayer of two tantalum carbides and metallic tantalum, depending on the temperature of the treatment and on the carbon content of the substrate. The thin films as well the substrates are characterized from the structural, chemical and morphological point of view. Moreover mechanical behaviour of treated and untreated materials is analyzed by means of nanohardness, scratch and ball-on-disc wear tests. The coating increases the mechanical and tribological properties of HC-CoCrMo.


Subject(s)
Chlorides/chemistry , Coated Materials, Biocompatible/chemistry , Prostheses and Implants , Tantalum/chemistry , Carbon/chemistry , Corrosion , Hardness , Humans , Ions/chemistry , Metals/chemistry , Temperature , Vitallium/chemistry
4.
J Mater Sci Mater Med ; 20(1): 75-87, 2009 Jan.
Article in English | MEDLINE | ID: mdl-18704658

ABSTRACT

The surface reactivity of different sets of glasses and glass-ceramics belonging to the SiO(2)-P(2)O(5)-CaO-MgO-K(2)O-Na(2)O system have been investigated. The attention was focused on the role of their composition on the bioactivity kinetics, in terms of pH modifications, silica-gel formation and its evolution toward hydroxycarbonatoapatite, after different times of soaking in simulated body fluid. Glasses and glass ceramics have been characterized by thermal analysis, SEM-EDS observations and phase analysis (XRD). XPS measurements have been carried out on the most representative set of sample in order to evaluate the evolution of the surface species during the growth of silica-gel and hydroxycarbonatoapatite. The response of murine fibroblast 3T3 to the material before and after a conditioning pre-treatment (immersion in SBF) has been investigated on the same set of samples in order to point out the role of the bioactivity mechanism on cell viability. The main differences among the various glasses have been related to the modifier oxides ratio and to the MgO content, which seems to have an influence on the glass stability, both in terms of thermal properties and surface reactivity. The surface characterization and in vitro tests revealed few variations in the reactivity of the different glasses and glass-ceramics in their pristine form. On the contrary, the different surface properties before and after the pre-treatment in SBF seem to play a role on the biocompatibility of both glass and glass-ceramics, due to the different ion release and hydrophilicity of the surfaces, affecting both cell viability and protein adsorption.


Subject(s)
Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Ceramics/chemistry , Glass/chemistry , Silicon Dioxide/chemistry , Adsorption , Animals , Blood Proteins/pharmacokinetics , Body Fluids , Cell Survival/drug effects , Humans , Hydrogen-Ion Concentration , Materials Testing , Mice , Microscopy, Electron, Scanning , NIH 3T3 Cells , Spectrum Analysis , Surface Properties , X-Ray Diffraction , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...