Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Contemp Dent Pract ; 14(6): 1065-9, 2013 Nov 01.
Article in English | MEDLINE | ID: mdl-24858752

ABSTRACT

CLINICAL SIGNIFICANCE: The apical extrusion of infected debris may have the potential to disrupt the balance between microbial aggression and host defense, resulting in incidents of acute inflammation. During preparation, irrigants and debris, such as bacteria, dentin filings and necrotic tissue may be extruded into the periradicular region leading to periapical inflammation and postoperative flare ups. Using an instrumentation technique that minimizes apical extrusion would be beneficial to both the practitioner and patient. The purpose of the study was to evaluate the weight of debris and volume of irrigant extruded apically from extracted teeth in vitro after endodontic instrumentation using four different rotary root canal instrumentation systems. MATERIALS AND METHODS: Four groups of each 20 extracted mandibular premolars were instrumented using one of the four systems: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland)), Hero-shaper (MicroMega, Besancon, France), RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) and K3 (SybronEndo, West Collins, CA). Debris and irrigant extruded from the apical foramen during instrumentation were collected in preweighed test tubes. Volume of irrigant extruded was noted. The containers were stored in incubator at 70° for two days to evaporate the moisture. Weight of dry debris was noted. STATISTICAL ANALYSIS: Data was analyzed using Kruskall-Wallis and Mann-Whitney U test at a significance of 0.001. RESULTS: The results indicated that all of the instrumentation systems tested caused measurable apical extrusion of debris and irrigants. Higher extrusion was observed with Protaper system which was statistically significant with Hero-Shaper, RaCe and K3 systems. There were no statistical differences between Hero-shaper, K3 and RaCe systems (p < 0.05). CONCLUSION: All instrumentation techniques apically extruded debris and irrigant. However, Hero-shaper, K3 and RaCe systems produced less extruded debris and irrigant than the Protaper system.


Subject(s)
Dental Pulp Cavity/pathology , Foreign Bodies/etiology , Periapical Tissue/pathology , Root Canal Irrigants/adverse effects , Root Canal Preparation/instrumentation , Tooth Apex/pathology , Bicuspid/pathology , Dental Pulp Cavity/microbiology , Dental Pulp Necrosis/microbiology , Dental Pulp Necrosis/pathology , Dentin/pathology , Equipment Design , Humans , Materials Testing , Periapical Periodontitis/etiology , Root Canal Irrigants/analysis , Root Canal Preparation/methods , Therapeutic Irrigation/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...