Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pediatr Crit Care Med ; 15(7): 600-7, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24977688

ABSTRACT

OBJECTIVES: Modified ultrafiltration is used to ameliorate the deleterious effects of cardiopulmonary bypass in pediatric cardiac surgery patients. The ideal duration of modified ultrafiltration has not been established yet. We investigated the effects of extended duration of modified ultrafiltration on pulmonary functions and hemodynamics in the early postoperative period in newborns and infants who had transposition of great arteries operations. DESIGN: Single-center prospective randomized study. SETTING: Pediatric cardiac surgery operating room and ICU. PATIENTS: Sixty newborns and infants who had been scheduled to undergo transposition of great arteries operation. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Modified ultrafiltration was applied to all patients following the termination of cardiopulmonary bypass (for 10, 15, and 20 min in groups 1, 2, and 3, respectively). Pulmonary compliance, gas exchange capacity, hemodynamic measurements, inotropic support, blood loss, transfusion requirements, hematocrit level, and duration of ventilatory support were measured after intubation, at termination of cardiopulmonary bypass, at the end of modified ultrafiltration, and in the 1st, 6th, 12th, and 24th hours after admission to ICU. The amount of fluid removed by modified ultrafiltration in groups 2 and 3 was larger than that of group 1 (p < 0.01). Systolic blood pressure was significantly increased at the end of modified ultrafiltration in group 3 compared to groups 1 and 2 (p < 0.05). Hematocrit levels were significantly increased at the end of modified ultrafiltration in groups 2 and 3 compared to group 1 (p < 0.01). Therefore, RBCs were transfused less after modified ultrafiltration in groups 2 and 3 compared to group 1 (p < 0.05). Static and dynamic compliance, oxygen index, and ventilation index had improved similarly in all three groups at the end of modified ultrafiltration (p > 0.05) CONCLUSIONS:: Modified ultrafiltration acutely improved pulmonary compliance and gas exchange in all groups. Increased hematocrit and blood pressure levels were also observed in the longer modified ultrafiltration group. However, extended duration of modified ultrafiltration did not have a significant impact on duration of intubation or the stay in ICU.


Subject(s)
Cardiopulmonary Bypass , Intensive Care, Neonatal , Transposition of Great Vessels/surgery , Ultrafiltration/methods , Female , Humans , Infant , Infant, Newborn , Lung Compliance , Male , Postoperative Care , Prospective Studies , Pulmonary Gas Exchange , Time Factors , Transposition of Great Vessels/physiopathology
2.
Ann Card Anaesth ; 17(1): 10-5, 2014.
Article in English | MEDLINE | ID: mdl-24401296

ABSTRACT

AIMS AND OBJECTIVES: We used near-infrared spectroscopy to document changes in cerebral tissue oxygen saturation (SctO2) in response to ventilation mode alterations after bidirectional Glenn (BDG; superior cavopulmonary connection) procedure. We also determined whether spontaneous ventilation have a beneficial effect on hemodynamic status, lactate and SctO2 when compared with other ventilation modes. MATERIALS AND METHODS: 20 consecutive patients undergoing BDG were included. We measured SctO 2 during three ventilator modes (intermittent positive-pressure ventilation [IPPV]; synchronized intermittent mandatory ventilation [SIMV]; and continuous positive airway pressure + pressure support ventilation [CPAP + PSV]). We, also, measured mean airway pressure (AWP), arterial blood gases, lactate and systolic arterial pressures (SAP). RESULTS: There was no change in SctO2 in IPPV and SIMV modes; the SctO2 measured during CPAP + PSV and after extubation increased significantly (60.5 ± 11, 61 ± 10, 65 ± 10, 66 ± 11 respectively) (P < 0.05). The differences in the SAP measured during IPPV and SIMV modes was insignificant; the SAP increased significantly during CPAP + PSV mode and after extubation compared with IPPV and SIMV (109 ± 11, 110 ± 12, 95 ± 17, 99 ± 13 mmHg, respectively) (P < 0.05). Mean AWP did not change during IPPV and SIMV modes, mean AWP decreased significantly during CPAP + PSV mode (14 ± 4, 14 ± 3, 10 ± 1 mmHg, respectively) (P < 0.01). CONCLUSIONS: The SctO2 was higher during CPAP + PSV ventilation and after extubation compared to IPPV and SIMV modes of ventilation. The mean AWP was lower during CPAP + PSV ventilation compared to IPPV and SIMV modes of ventilation.


Subject(s)
Brain Chemistry/physiology , Oxygen Consumption/physiology , Ventilators, Mechanical , Anesthesia, General , Cardiopulmonary Bypass , Critical Care , Female , Humans , Infant , Intermittent Positive-Pressure Ventilation , Male , Oxygen/blood , Positive-Pressure Respiration , Respiration, Artificial/methods , Spectroscopy, Near-Infrared , Vascular Surgical Procedures
SELECTION OF CITATIONS
SEARCH DETAIL
...