Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Insights Imaging ; 13(1): 90, 2022 May 13.
Article in English | MEDLINE | ID: mdl-35554734

ABSTRACT

OBJECTIVE: To evaluate the effectiveness of a new algorithm developed to reduce artifacts in dual-energy subtraction (DES) contrast-enhanced mammography (CEM) images while preserving contrast enhancement of possible lesions. METHODS: A retrospective multi-reader paired study was performed by using 134 CEM studies obtained from the first 134 women enrolled in a prospective clinical study aiming to compare the clinical performance of CEM to those of breast MRI in screening of women at increased risk of breast cancer. Four experienced readers compared independently the standard (STD) DES images with those obtained by reprocessing the raw images by a new algorithm (NEW), expected to reduce the DES artifact intensity. The intensity of three types of artifacts (breast-in-breast, ripple, and skinfold enhancement) and the intensity of possible contrast uptake were assessed visually and rated using a categorical ordinal scale. Proportions of images rated by the majority of readers as "Absent", "Weak", "Medium", "Strong" in each artifact intensity category were compared between the two algorithms. P-values lower than 0.05 were considered statistically significant. RESULTS: The NEW algorithm succeeded in eliminating 84.5% of breast-in-breast artifacts, 84.2% of ripple artifacts, and 56.9% of skinfold enhancement artifacts versus STD DES images, and reduced the artifact intensity in 12.1%, 13.0%, and 28.8% of the images, respectively. The visibility of lesion contrast uptake was the same with the STD and the NEW algorithms. CONCLUSION: The new dual-energy subtraction algorithm demonstrated to be effective in reducing/eliminating CEM-related artifacts while preserving lesion contrast enhancement.

2.
Eur Radiol ; 23(9): 2441-9, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23673573

ABSTRACT

OBJECTIVES: To compare the diagnostic performance of single-view breast tomosynthesis (BT) with that of dual-view mammography (MX); to assess the benefit of adding the craniocaudal (CC) mammographic view to BT, and of adding BT to MX plus breast ultrasound, considered to be the reference work-up. METHODS: One hundred and fifty-five consenting patients with unresolved mammographic and/or ultrasound findings or breast symptoms underwent conventional work-up plus mediolateral oblique-view BT of the affected breast. The final study set in 130 patients resulted in 55 malignant and 76 benign and normal cases. Seven breast radiologists rated the cases through five sequential techniques using a BIRADS-based scale: MX, MX + ultrasound, MX + ultrasound + BT, BT, BT + MX(CC). Multireader, multicase receiver operating characteristic (ROC) analysis was performed and performance of the techniques was assessed from the areas under ROC curves. The performance of BT and of BT + MX(CC) was tested versus MX; the performance of MX + ultrasound + BT tested versus MX + ultrasound. RESULTS: Tomosynthesis was found to be non-inferior to mammography. BT + MX(CC) did not appear to be superior to MX, and MX + ultrasound + BT not superior to MX + ultrasound. CONCLUSIONS: Overall, none of the five techniques tested outperformed the others. Further clinical studies are needed to clarify the role of BT as a substitute for traditional work-up in the diagnostic environment. KEY POINTS: • Digital breast tomosynthesis is a new adjunct to mammography and breast ultrasound. • We compared the diagnostic performance of these investigations in an experimental observer study. • Single-view breast tomosynthesis was confirmed as non-inferior to dual-view mammography. • None of the investigations (or combinations) tested outperformed the others. • Further prospective studies are needed to clarify precise role of tomosynthesis for diagnostic application.


Subject(s)
Breast Neoplasms/diagnostic imaging , Imaging, Three-Dimensional/methods , Mammography/methods , Ultrasonography, Mammary/methods , Adult , Aged , Aged, 80 and over , Area Under Curve , Breast/pathology , Female , Humans , Mammography/instrumentation , Middle Aged , Observer Variation , Predictive Value of Tests , Prospective Studies , ROC Curve , Radiographic Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Sensitivity and Specificity , Ultrasonography, Mammary/instrumentation
3.
Eur Radiol ; 23(8): 2087-94, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23620367

ABSTRACT

OBJECTIVE: To evaluate the clinical value of combining one-view mammography (cranio-caudal, CC) with the complementary view tomosynthesis (mediolateral-oblique, MLO) in comparison to standard two-view mammography (MX) in terms of both lesion detection and characterization. METHODS: A free-response receiver operating characteristic (FROC) experiment was conducted independently by six breast radiologists, obtaining data from 463 breasts of 250 patients. Differences in mean lesion detection fraction (LDF) and mean lesion characterization fraction (LCF) were analysed by analysis of variance (ANOVA) to compare clinical performance of the combination of techniques to standard two-view digital mammography. RESULTS: The 463 cases (breasts) reviewed included 258 with one to three lesions each, and 205 with no lesions. The 258 cases with lesions included 77 cancers in 68 breasts and 271 benign lesions to give a total of 348 proven lesions. The combination, DBT(MLO)+MX(CC), was superior to MX (CC+MLO) in both lesion detection (LDF) and lesion characterization (LCF) overall and for benign lesions. DBT(MLO)+MX(CC) was non-inferior to two-view MX for malignant lesions. CONCLUSIONS: This study shows that readers' capabilities in detecting and characterizing breast lesions are improved by combining single-view digital breast tomosynthesis and single-view mammography compared to two-view digital mammography. KEY POINTS: • Digital breast tomosynthesis is becoming adopted as an adjunct to mammography (MX) • DBT (MLO) +MX (CC) is superior to MX (CC+MLO) in lesion detection (overall and benign lesions) • DBT (MLO) +MX (CC) is non-inferior to MX (CC+MLO) in cancer detection • DBT (MLO) +MX (CC) is superior to MX (CC+MLO) in lesion characterization (overall and benign lesions) • DBT (MLO) +MX (CC) is non-inferior to MX (CC+MLO) in characterization of malignant lesions.


Subject(s)
Breast Neoplasms/diagnostic imaging , Imaging, Three-Dimensional/methods , Mammography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Breast/pathology , False Positive Reactions , Female , Humans , Middle Aged , Multimodal Imaging/methods , Observer Variation , ROC Curve , Radiographic Image Enhancement/methods , Reproducibility of Results
4.
Eur Radiol ; 23(3): 664-72, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22976919

ABSTRACT

OBJECTIVE: To determine the performance of combined single-view mediolateral oblique (MLO) digital breast tomosynthesis (DBT) plus single-view cranio-caudal (CC) mammography (MX) compared with that of standard two-view digital mammography. METHODS: A multi-reader multi-case (MRMC) receiver-operating characteristic (ROC) study was conducted, involving six breast radiologists. Two hundred fifty patients underwent bilateral MX and DBT imaging. MX and DBT images with the adjunct of the CC-MX view from 469 breasts were evaluated and rated independently by six readers. Differences in mean areas under the ROC curves (AUCs), mean sensitivity and mean specificity were analysed by analysis of variance (ANOVA) to assess clinical performance. RESULTS: The combined technique was found to be non-inferior to standard two-view mammography (MX((CC+MLO))) in mean AUC (difference: +0.021;95 % LCL = -0.011), but was not statistically significant for superiority (P = 0.197). The combined technique had equivalent sensitivity to standard mammography (76.2 % vs. 72.8 %, P = 0.269) and equivalent specificity (84.9 % vs. 83.0 %, P = 0.130). Specificity for benign lesions was significantly higher with the combination of techniques versus mammography (45.6 % vs. 36.8 %, P = 0.002). CONCLUSION: In this enriched study population, the combination of single-view MLO tomosynthesis plus single-view CC mammography was non-inferior to that of standard two-view digital mammography in terms of ROC curve area, sensitivity and specificity.


Subject(s)
Breast Neoplasms/diagnostic imaging , Imaging, Three-Dimensional/methods , Mammography/methods , Patient Positioning/methods , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Reproducibility of Results , Sensitivity and Specificity
5.
Eur Radiol ; 20(7): 1545-53, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20033175

ABSTRACT

OBJECTIVE: To compare the clinical performance of digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) in a diagnostic population. METHODS: The study enrolled 200 consenting women who had at least one breast lesion discovered by mammography and/or ultrasound classified as doubtful or suspicious or probably malignant. They underwent tomosynthesis in one view [mediolateral oblique (MLO)] of both breasts at a dose comparable to that of standard screen-film mammography in two views [craniocaudal (CC) and MLO]. Images were rated by six breast radiologists using the BIRADS score. Ratings were compared with the truth established according to the standard of care and a multiple-reader multiple-case (MRMC) receiver-operating characteristic (ROC) analysis was performed. Clinical performance of DBT compared with that of FFDM was evaluated in terms of the difference between areas under ROC curves (AUCs) for BIRADS scores. RESULTS: Overall clinical performance with DBT and FFDM for malignant versus all other cases was not significantly different (AUCs 0.851 vs 0.836, p = 0.645). The lower limit of the 95% CI or the difference between DBT and FFDM AUCs was -4.9%. CONCLUSION: Clinical performance of tomosynthesis in one view at the same total dose as standard screen-film mammography is not inferior to digital mammography in two views.


Subject(s)
Breast Neoplasms/diagnosis , Breast/pathology , Mammography/methods , Radiographic Image Enhancement/methods , Breast Neoplasms/diagnostic imaging , Female , Humans , Observer Variation , ROC Curve , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...