Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Am J Physiol Renal Physiol ; 327(1): F113-F127, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38660712

ABSTRACT

The kidneys maintain fluid-electrolyte balance and excrete waste in the presence of constant fluctuations in plasma volume and systemic blood pressure. The kidneys perform these functions to control capillary perfusion and glomerular filtration by modulating the mechanisms of autoregulation. An effect of these modulations are spontaneous, natural fluctuations in glomerular perfusion. Numerous other mechanisms can lead to fluctuations in perfusion and flow. The ability to monitor these spontaneous physiological fluctuations in vivo could facilitate the early detection of kidney disease. The goal of this work was to investigate the use of resting-state magnetic resonance imaging (rsMRI) to detect spontaneous physiological fluctuations in the kidney. We performed rsMRI of rat kidneys in vivo over 10 min, applying motion correction to resolve time series in each voxel. We observed spatially variable, spontaneous fluctuations in rsMRI signal between 0 and 0.3 Hz, in frequency bands associated with autoregulatory mechanisms. We further applied rsMRI to investigate changes in these fluctuations in a rat model of diabetic nephropathy. Spectral analysis was performed on time series of rsMRI signals in the kidney cortex and medulla. The power from spectra in specific frequency bands from the cortex correlated with severity of glomerular pathology caused by diabetic nephropathy. Finally, we investigated the feasibility of using rsMRI of the human kidney in two participants, observing the presence of similar, spatially variable fluctuations. This approach may enable a range of preclinical and clinical investigations of kidney function and facilitate the development of new therapies to improve outcomes in patients with kidney disease.NEW & NOTEWORTHY This work demonstrates the development and use of resting-state MRI to detect low-frequency, spontaneous physiological fluctuations in the kidney consistent with previously observed fluctuations in perfusion and potentially due to autoregulatory function. These fluctuations are detectable in rat and human kidneys, and the power of these fluctuations is affected by diabetic nephropathy in rats.


Subject(s)
Diabetic Nephropathies , Kidney , Magnetic Resonance Imaging , Rats, Sprague-Dawley , Animals , Diabetic Nephropathies/physiopathology , Diabetic Nephropathies/diagnostic imaging , Magnetic Resonance Imaging/methods , Male , Kidney/physiopathology , Kidney/diagnostic imaging , Rats , Diabetes Mellitus, Experimental/physiopathology , Diabetes Mellitus, Experimental/diagnostic imaging , Renal Circulation , Humans , Homeostasis/physiology
2.
Methods Mol Biol ; 2664: 201-213, 2023.
Article in English | MEDLINE | ID: mdl-37423992

ABSTRACT

Cationic ferritin (CF) has been developed as a multimodal, targeted imaging tracer to directly detect and map nephrons in the kidney in vivo. Direct detection of functional nephrons provides a unique, sensitive biomarker to predict or monitor kidney disease progression. CF has been developed to map functional nephron number from magnetic resonance imaging (MRI) or positron emission tomography (PET). Previous preclinical imaging studies have used non-human-derived ferritin and commercial formulations that must still be developed for translation to clinical use. Here we describe the reproducible formulation of CF (either derived from horse or from human recombinant ferritin) optimized for intravenous injection and radiolabeling by PET. The human recombinant heteropolymer ferritin is spontaneously assembled in liquid culture (Escherichia coli, E. coli) and modified to form human recombinant cationic ferritin (HrCF) to mitigate potential immunologic reactions for use in humans.


Subject(s)
Escherichia coli , Ferritins , Animals , Horses , Kidney Glomerulus/pathology , Kidney/diagnostic imaging , Positron-Emission Tomography , Magnetic Resonance Imaging/methods
3.
BMC Nephrol ; 24(1): 178, 2023 06 19.
Article in English | MEDLINE | ID: mdl-37331957

ABSTRACT

BACKGROUND: A significant barrier to biomarker development in the field of acute kidney injury (AKI) is the use of kidney function to identify candidates. Progress in imaging technology makes it possible to detect early structural changes prior to a decline in kidney function. Early identification of those who will advance to chronic kidney disease (CKD) would allow for the initiation of interventions to halt progression. The goal of this study was to use a structural phenotype defined by magnetic resonance imaging and histology to advance biomarker discovery during the transition from AKI to CKD. METHODS: Urine was collected and analyzed from adult C57Bl/6 male mice at four days and 12 weeks after folic acid-induced AKI. Mice were euthanized 12 weeks after AKI and structural metrics were obtained from cationic ferritin-enhanced-MRI (CFE-MRI) and histologic assessment. The fraction of proximal tubules, number of atubular glomeruli (ATG), and area of scarring were measured histologically. The correlation between the urinary biomarkers at the AKI or CKD and CFE-MRI derived features was determined, alone or in combination with the histologic features, using principal components. RESULTS: Using principal components derived from structural features, twelve urinary proteins were identified at the time of AKI that predicted structural changes 12 weeks after injury. The raw and normalized urinary concentrations of IGFBP-3 and TNFRII strongly correlated to the structural findings from histology and CFE-MRI. Urinary fractalkine concentration at the time of CKD correlated with structural findings of CKD. CONCLUSIONS: We have used structural features to identify several candidate urinary proteins that predict whole kidney pathologic features during the transition from AKI to CKD, including IGFBP-3, TNFRII, and fractalkine. In future work, these biomarkers must be corroborated in patient cohorts to determine their suitability to predict CKD after AKI.


Subject(s)
Acute Kidney Injury , Renal Insufficiency, Chronic , Male , Mice , Animals , Insulin-Like Growth Factor Binding Protein 3 , Chemokine CX3CL1/metabolism , Renal Insufficiency, Chronic/diagnostic imaging , Renal Insufficiency, Chronic/pathology , Acute Kidney Injury/pathology , Biomarkers/metabolism
4.
Am J Physiol Renal Physiol ; 323(5): F602-F611, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36049066

ABSTRACT

The kidney has an extraordinary ability to maintain glomerular filtration despite natural fluctuations in blood pressure and nephron loss. This is partly due to local coordination between single-nephron filtration and vascular perfusion. An improved understanding of the three-dimensional (3-D) functional coordination between nephrons and the vasculature may provide a new perspective of the heterogeneity of kidney function and could inform targeted therapies and timed interventions to slow or prevent the progression of kidney disease. Here, we developed magnetic resonance imaging (MRI) tools to visualize single-nephron function in 3-D throughout the isolated perfused rat kidney. We used an intravenous slow perfusion of a glomerulus-targeted imaging tracer [cationized ferritin (CF)] to map macromolecular dynamics and to identify glomeruli in 3-D, followed by a bolus of a freely filtered tracer (gadolinium diethylenetriamine penta-acetic acid) to map filtration kinetics. There was a wide intrakidney distribution of CF binding rates and estimated single-nephron glomerular filtration rate (eSNGFR) between nephrons. eSNGFR and CF uptake rates did not vary significantly by distance from the kidney surface. eSNGFR varied from ∼10 to ∼100 nL/min throughout the kidney. Whole single-kidney GFR was similar across all kidneys, despite differences in the distributions eSNGFR of and glomerular number, indicating a robust adaptive regulation of individual nephrons to maintain constant single-kidney GFR in the presence of a natural variation in nephron number. This work provides a framework for future studies of single-nephron function in the whole isolated perfused kidney and experiments of single-nephron function in vivo using MRI.NEW & NOTEWORTHY We report MRI tools to measure and map single-nephron function in the isolated, perfused rat kidney. We used imaging tracers to identify nephrons throughout the kidney and to measure the delivery and filtration of the tracers at the location of the glomeruli. With this technique, we directly measured physiological parameters including estimated single-nephron glomerular filtration rate throughout the kidney. This work provides a foundation for new studies to simultaneously map the function of large numbers of nephrons.


Subject(s)
Gadolinium , Kidney Diseases , Animals , Rats , Nephrons/pathology , Kidney Glomerulus/pathology , Glomerular Filtration Rate , Kidney/diagnostic imaging , Kidney/pathology , Kidney Diseases/pathology , Magnetic Resonance Imaging/methods
6.
J Am Soc Nephrol ; 33(1): 39-48, 2022 01.
Article in English | MEDLINE | ID: mdl-34758983

ABSTRACT

BACKGROUND: Accumulating evidence supports an association between nephron number and susceptibility to kidney disease. However, it is not yet possible to directly measure nephron number in a clinical setting. Recent clinical studies have used glomerular density from a single biopsy and whole kidney cortical volume from imaging to estimate nephron number and single nephron glomerular filtration rate. However, the accuracy of these estimates from individual subjects is unknown. Furthermore, it is not clear how sample size or biopsy location may influence these estimates. These questions are critical to study design, and to the potential translation of these tools to estimate nephron number in individual subjects. METHODS: We measured the variability in estimated nephron number derived from needle or virtual biopsies and cortical volume in human kidneys declined for transplantation. We performed multiple needle biopsies in the same kidney, and examined the three-dimensional spatial distribution of nephron density by magnetic resonance imaging. We determined the accuracy of a single-kidney biopsy to predict the mean nephron number estimated from multiple biopsies from the same kidney. RESULTS: A single needle biopsy had a 15% chance and virtual biopsy had a 60% chance of being within 20% of the whole-kidney nephron number. Single needle biopsies could be used to detect differences in nephron number between large cohorts of several hundred subjects. CONCLUSIONS: The number of subjects required to accurately detect differences in nephron number between populations can be predicted on the basis of natural intrakidney variability in glomerular density. A single biopsy is insufficient to accurately predict nephron number in individual subjects.


Subject(s)
Nephrons/pathology , Adult , Aged , Aged, 80 and over , Biopsy, Needle , Cohort Studies , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Nephrons/diagnostic imaging , Organ Size , Reproducibility of Results , Young Adult
7.
Am J Physiol Renal Physiol ; 321(3): F293-F304, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34282957

ABSTRACT

Kidney pathologies are often highly heterogeneous. To comprehensively understand kidney structure and pathology, it is critical to develop tools to map tissue microstructure in the context of the whole, intact organ. Magnetic resonance imaging (MRI) can provide a unique, three-dimensional view of the kidney and allows for measurements of multiple pathological features. Here, we developed a platform to systematically render and map gross and microstructural features of the human kidney based on three-dimensional MRI. These features include pyramid number and morphology as well as the associated medulla and cortex. In a subset of these kidneys, we also mapped individual glomeruli and glomerular volumes using cationic ferritin-enhanced MRI to report intrarenal heterogeneity in glomerular density and size. Finally, we rendered and measured regions of nephron loss due to pathology and individual glomerular volumes in each pyramidal unit. This work provides new tools to comprehensively evaluate the kidney across scales, with potential applications in anatomic and physiological research, transplant allograft evaluation, biomarker development, biopsy guidance, and therapeutic monitoring. These image rendering and analysis tools could eventually impact the field of transplantation medicine to improve longevity matching of donor allografts and recipients and reduce discard rates through the direct assessment of donor kidneys.NEW & NOTEWORTHY We report the application of cutting-edge image analysis approaches to characterize the pyramidal geometry, glomerular microstructure, and heterogeneity of the whole human kidney imaged using MRI. This work establishes a framework to improve the detection of microstructural pathology to potentially facilitate disease monitoring or transplant evaluation in the individual kidney.


Subject(s)
Image Processing, Computer-Assisted , Kidney Diseases/pathology , Kidney Glomerulus/pathology , Nephrons/pathology , Ferritins/metabolism , Humans , Kidney/pathology , Kidney Glomerulus/metabolism , Magnetic Resonance Imaging/methods , Urinary Tract/pathology
8.
Kidney Int ; 99(1): 173-185, 2021 01.
Article in English | MEDLINE | ID: mdl-32916180

ABSTRACT

Acute kidney injury (AKI) increases the risk for chronic kidney disease (CKD). However, there are few tools to detect microstructural changes after AKI. Here, cationic ferritin-enhanced magnetic resonance imaging (CFE-MRI) was applied to examine the heterogeneity of kidney pathology in the transition from AKI to CKD. Adult male mice received folic acid followed by cationic ferritin and were euthanized at four days (AKI), four weeks (CKD-4) or 12 weeks (CKD-12). Kidneys were examined by histologic methods and CFE-MRI. In the CKD-4 and CKD-12 groups, glomerular number was reduced and atubular cortical lesions were observed. Apparent glomerular volume was larger in the AKI, CKD-4 and CKD-12 groups compared to controls. Glomerular hypertrophy occurred with ageing. Interglomerular distance and glomerular density were combined with other MRI metrics to distinguish the AKI and CKD groups from controls. Despite significant heterogeneity, the noninvasive (MRI-based) metrics were as accurate as invasive (histological) metrics at distinguishing AKI and CKD from controls. To assess the toxicity of cationic ferritin in a CKD model, CKD-4 mice received cationic ferritin and were examined one week later. The CKD-4 groups with and without cationic ferritin were similar, except the iron content of the kidney, liver, and spleen was greater in the CKD-4 plus cationic ferritin group. Thus, our study demonstrates the accuracy and safety of CFE-MRI to detect whole kidney pathology allowing for the development of novel biomarkers of kidney disease and providing a foundation for future in vivo longitudinal studies in mouse models of AKI and CKD to track nephron fate.


Subject(s)
Acute Kidney Injury , Renal Insufficiency, Chronic , Acute Kidney Injury/diagnostic imaging , Animals , Kidney/diagnostic imaging , Kidney Glomerulus , Magnetic Resonance Imaging , Male , Mice , Renal Insufficiency, Chronic/diagnostic imaging
9.
Pediatr Nephrol ; 36(4): 797-807, 2021 04.
Article in English | MEDLINE | ID: mdl-32350665

ABSTRACT

Studies of human nephron number have been conducted for well over a century and have uncovered a large variability in nephron number. However, the mechanisms influencing nephron endowment and loss, along with the etiology for the wide range among individuals are largely unknown. Advances in imaging technology have allowed investigators to revisit the principles of renal structure and physiology and their roles in the progression of kidney disease. Here, we will review the latest data on the influences impacting nephron number, innovations made over the last 6 years to understand and integrate renal structure and function, and new developments in the tools used to count nephrons in vivo.


Subject(s)
Kidney Diseases , Nephrons , Humans , Kidney
10.
Am J Physiol Renal Physiol ; 320(2): F183-F192, 2021 02 01.
Article in English | MEDLINE | ID: mdl-33283644

ABSTRACT

Nephron number varies widely in humans. A low nephron endowment at birth or a loss of functioning nephrons is strongly linked to increased susceptibility to chronic kidney disease. In this work, we developed a contrast agent, radiolabeled cationic ferritin (RadioCF), to map functioning glomeruli in vivo in the kidney using positron emission tomography (PET). PET radiotracers can be detected in trace doses (<30 nmol), making them useful for rapid clinical translation. RadioCF is formed from cationic ferritin (CF) and with a radioisotope, Cu-64, incorporated into the ferritin core. We showed that RadioCF binds specifically to kidney glomeruli after intravenous injection in mice, whereas radiolabeled noncationic ferritin (RadioNF) and free Cu-64 do not. We then showed that RadioCF-PET can distinguish kidneys in healthy wild-type (WT) mice from kidneys in mice with oligosyndactylism (Os/+), a model of congenital hypoplasia and low nephron mass. The average standardized uptake value (SUV) measured by PET 90 min after injection was 21% higher in WT mice than in Os/+ mice, consistent with the higher glomerular density in WT mice. The difference in peak SUV from SUV at 90 min correlated with glomerular density in male mice from both WT and Os/+ cohorts (R2 = 0.98). Finally, we used RadioCF-PET to map functioning glomeruli in a donated human kidney. SUV within the kidney correlated with glomerular number (R2= 0.78) measured by CF-enhanced magnetic resonance imaging in the same locations. This work suggests that RadioCF-PET appears to accurately detect nephron mass and has the potential for clinical translation.


Subject(s)
Ferritins/chemistry , Ferritins/metabolism , Nephrons/anatomy & histology , Aged , Animals , Contrast Media , Copper Radioisotopes , Female , Glomerular Filtration Rate , Humans , Kidney/anatomy & histology , Kidney Transplantation , Male , Mice , Positron-Emission Tomography , Tissue Donors
11.
Anat Rec (Hoboken) ; 303(10): 2716-2728, 2020 10.
Article in English | MEDLINE | ID: mdl-32445514

ABSTRACT

Acute kidney injury (AKI) in premature neonates is common due to the administration of life-saving therapies. The impact of AKI on renal morphology and susceptibility to further renal damage is poorly understood. Recent advances in radiological imaging have allowed integration of soft tissue morphology in the intact organ, facilitating a more complete understanding of changes in tissue microstructure associated with pathology. Here, we applied magnetic resonance imaging (MRI) to detect both glomerular and vascular changes in a rabbit model of neonatal AKI, induced by indomethacin and gentamicin. Using combined spin-echo MRI and cationic ferritin enhanced gradient-echo MRI (CFE-MRI), we observed (a) an increased cortical arterial diameter in the AKI cohort compared to healthy controls, and (b) focal loss of vascular density and glomerular loss in a circumferential band ~1 mm from the cortical surface. This combined use of vascular and glomerular imaging may give insight into the etiology of AKI and its impact on renal health later in life.


Subject(s)
Acute Kidney Injury/pathology , Kidney Glomerulus/pathology , Kidney/pathology , Acute Kidney Injury/chemically induced , Acute Kidney Injury/diagnostic imaging , Animals , Animals, Newborn , Disease Models, Animal , Gentamicins , Indomethacin , Kidney/diagnostic imaging , Kidney Glomerulus/diagnostic imaging , Magnetic Resonance Imaging , Rabbits
12.
Pediatr Res ; 87(7): 1185-1192, 2020 06.
Article in English | MEDLINE | ID: mdl-31805577

ABSTRACT

BACKGROUND: Acute kidney injury affects nearly 30% of preterm neonates in the intensive care unit. We aimed to determine whether nephrotoxin-induced AKI disrupted renal development assessed by imaging (CFE-MRI). METHODS: Neonatal New Zealand rabbits received indomethacin and gentamicin (AKI) or saline (control) for four days followed by cationic ferritin (CF) at six weeks. Ex vivo images were acquired using a gradient echo pulse sequence on 7 T MRI. Glomerular number (Nglom) and apparent glomerular volume (aVglom) were determined. CF toxicity was assessed at two and 28 days in healthy rabbits. RESULTS: Nglom was lower in the AKI group as compared to controls (74,034 vs 198,722, p < 0.01). aVglom was not different (AKI: 7.3 × 10-4 vs control: 6.2 × 10-4 mm3, p = 0.69). AKI kidneys had a band of glomeruli distributed radially in the cortex that were undetectable by MRI. Following CF injection, there was no difference in body or organ weights except for the liver, and transient changes in serum iron, platelets and white blood cell count. CONCLUSIONS: Brief nephrotoxin exposure during nephrogenesis results in fewer glomeruli and glomerular maldevelopment in a unique pattern detectable by MRI. Whole kidney evaluation by CFE-MRI may provide an important tool to understand the development of CKD following AKI.


Subject(s)
Acute Kidney Injury/pathology , Magnetic Resonance Imaging/methods , Nephrons/pathology , Acute Kidney Injury/diagnostic imaging , Animals , Animals, Newborn , Cations , Disease Models, Animal , Ferritins/administration & dosage , Gentamicins/administration & dosage , Indomethacin/administration & dosage , Kidney Glomerulus/drug effects , Kidney Glomerulus/pathology , Rabbits
13.
Am J Physiol Renal Physiol ; 317(4): F865-F873, 2019 10 01.
Article in English | MEDLINE | ID: mdl-31339774

ABSTRACT

The development of chronic kidney disease (CKD) is associated with the loss of functional nephrons. However, there are no methods to directly measure nephron number in living subjects. Thus, there are no methods to track the early stages of progressive CKD before changes in total renal function. In this work, we used cationic ferritin-enhanced magnetic resonance imaging (CFE-MRI) to enable measurements of glomerular number (Nglom) and apparent glomerular volume (aVglom) in vivo in healthy wild-type (WT) mice (n = 4) and mice with oligosyndactylism (Os/+; n = 4), a model of congenital renal hypoplasia leading to nephron reduction. We validated in vivo measurements of Nglom and aVglom by high-resolution ex vivo MRI. CFE-MRI measured a mean Nglom of 12,220 ± 2,028 and 6,848 ± 1,676 (means ± SD) for WT and Os/+ mouse kidneys in vivo, respectively. Nglom measured in all mice in vivo using CFE-MRI varied by an average 15% from Nglom measured ex vivo in the same kidney (α = 0.05, P = 0.67). To confirm that CFE-MRI can also be used to track nephron endowment longitudinally, a WT mouse was imaged three times by CFE-MRI over 2 wk. Values of Nglom measured in vivo in the same kidney varied within ~3%. Values of aVglom calculated from CFE-MRI in vivo were significantly different (~15% on average, P < 0.01) from those measured ex vivo, warranting further investigation. This is the first report of direct measurements of Nglom and aVglom in healthy and diseased mice in vivo.


Subject(s)
Kidney Glomerulus/pathology , Syndactyly/pathology , Animals , Disease Progression , Image Processing, Computer-Assisted , Kidney Diseases/congenital , Kidney Diseases/diagnostic imaging , Kidney Diseases/pathology , Kidney Glomerulus/diagnostic imaging , Magnetic Resonance Imaging , Male , Mice , Mice, Inbred C57BL , Nephrons/pathology , Signal-To-Noise Ratio , Syndactyly/diagnostic imaging
14.
Am J Physiol Renal Physiol ; 314(3): F399-F406, 2018 03 01.
Article in English | MEDLINE | ID: mdl-29092847

ABSTRACT

number is highly variable in humans and is thought to play an important role in renal health. Chronic kidney disease (CKD) is the result of too few nephrons to maintain homeostasis. Currently, nephron number can only be determined invasively or as a terminal assessment. Due to a lack of tools to measure and track nephron number in the living, the early stages of CKD often go unrecognized, preventing early intervention that might halt the progression of CKD. In this work, we present a technique to directly measure glomerular number ( Nglom) and volume in vivo in the rat kidney ( n = 8) using MRI enhanced with the novel contrast agent cationized ferritin (CFE-MRI). Adult male rats were administered intravenous cationized ferritin (CF) and imaged in vivo with MRI. Glomerular number was measured and each glomerulus was spatially mapped in 3D in the image. Mean apparent glomerular volume (a Vglom) and intrarenal distribution of the individual glomerular volume (IGV), were also measured. These metrics were compared between images of the same kidneys scanned in vivo and ex vivo with CFE-MRI. In vivo Nglom and a Vglom correlated to ex vivo metrics within the same kidneys and were within 10% of Nglom and a Vglom previously validated by stereologic methods. This is the first report of direct in vivo measurements of Nglom and a Vglom, introducing an opportunity to investigate mechanisms of renal disease progression and therapeutic response over time.


Subject(s)
Kidney Diseases/diagnostic imaging , Kidney Glomerulus/diagnostic imaging , Magnetic Resonance Imaging/methods , Animals , Contrast Media/administration & dosage , Disease Models, Animal , Ferritins/administration & dosage , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Kidney Diseases/pathology , Kidney Glomerulus/pathology , Male , Predictive Value of Tests , Rats, Sprague-Dawley , Reproducibility of Results , Software
15.
Nanomedicine ; 12(6): 1735-45, 2016 08.
Article in English | MEDLINE | ID: mdl-27071333

ABSTRACT

Ferritin is a naturally occurring iron storage protein, proposed as a clinically relevant nanoparticle with applications as a diagnostic and therapeutic agent. Cationic ferritin is a targeted, injectable contrast agent to measure kidney microstructure with MRI. Here, the toxicity of horse spleen ferritin is assessed as a step to clinical translation. Adult male mice received cationic, native and high dose cationic ferritin (CF, NF, or HDCF) or saline and were monitored for 3weeks. Transient weight loss occurred in the ferritin groups with no difference in renal function parameters. Ferritin-injected mice demonstrated a lower serum iron 3weeks after administration. In ferritin-injected animals pre-treated with hydrocortisone, there were no structural or weight differences in the kidneys, liver, lung, heart, or spleen. This study demonstrates a lack of significant detrimental effects of horse-derived ferritin-based nanoparticles at MRI-detectable doses, allowing further exploration of these agents in basic research and clinical diagnostics.


Subject(s)
Contrast Media , Ferritins , Magnetic Resonance Imaging/methods , Nanoparticles , Animals , Horses , Iron , Liver , Male , Mice
16.
Am J Physiol Renal Physiol ; 310(11): F1328-36, 2016 06 01.
Article in English | MEDLINE | ID: mdl-26984953

ABSTRACT

Glomerular volume is an important metric reflecting glomerular filtration surface area within the kidney. Glomerular hypertrophy, or increased glomerular volume, may be an important marker for renal stress. Current stereological techniques report the average glomerular volume (AVglom) within the kidney. These techniques cannot assess the spatial or regional heterogeneity common in developing renal pathology. Here, we report a novel "unfolding" technique to measure the actual distribution of individual glomerular volumes in a kidney from the two-dimensional glomerulus profiles observed by optical microscopy. The unfolding technique was first developed and tested for accuracy with simulations and then applied to measure the number of glomeruli (Nglom), AVglom, and intrarenal distribution of individual glomerular volume (IVglom) in the oligosyndactyl (Os/(+)) mouse model compared with wild-type (WT) controls. The Os/(+) mice had fewer and larger glomeruli than WT mice: Nglom was 12,126 ± 1,658 (glomeruli/kidney) in the WT mice and 5,516 ± 899 in the Os/(+) mice; AVglom was 2.01 ± 0.28 × 10(-4) mm(3) for the WT mice and 3.47 ± 0.35 × 10(-4) mm(3) for the Os/(+) mice. Comparing the glomerular volume distributions in Os/(+) and WT kidneys, we observed that the Os/(+) distribution peaked at a higher value of IVglom than the WT distribution peak, and glomeruli with a radius greater than 55 µm were more prevalent in the Os/(+) mice (3.4 ± 1.6% of total glomeruli vs. 0.6 ± 1.2% in WT). Finally, the largest profiles were more commonly found in the juxtamedullary region. Unfolding is a novel stereological technique that provides a new quantitative view of glomerular volume distribution in the individual kidney.


Subject(s)
Kidney Diseases/pathology , Kidney Glomerulus/pathology , Kidney/pathology , Nephrons/pathology , Algorithms , Animals , Mice , Organ Size/physiology
17.
Methods Mol Biol ; 1397: 67-79, 2016.
Article in English | MEDLINE | ID: mdl-26676128

ABSTRACT

Magnetic resonance imaging (MRI) is becoming important for whole-kidney assessment of glomerular morphology, both in vivo and ex vivo. MRI-based renal morphological measurements can be made in intact organs and allow direct measurements of every perfused glomerulus. Cationic ferritin (CF) is used as a superparamagnetic contrast agent for MRI. CF binds to the glomerular basement membrane after intravenous injection, allowing direct, whole-kidney measurements of glomerular number, volume, and volume distribution. Here we describe the production, testing, and use of CF as an MRI contrast agent for quantitative glomerular morphology in intact mouse, rat, and human kidneys.


Subject(s)
Ferritins , Kidney Glomerulus/cytology , Kidney Glomerulus/ultrastructure , Magnetic Resonance Imaging , Metal Nanoparticles , Animals , Ferritins/chemistry , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/methods , Mice , Rats
18.
Kidney Int ; 89(2): 498-505, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26535998

ABSTRACT

Reduced nephron mass is strongly linked to susceptibility to chronic renal and cardiovascular diseases. There are currently no tools to identify nephropenia in clinical or preclinical diagnostics. Such new methods could uncover novel mechanisms and therapies for chronic kidney disease (CKD) and reveal how variation among traits can affect renal function and morphology. Here we used cationized ferritin (CF)­enhanced MRI (CFE-MRI) to investigate the relationship between glomerular number (Nglom) and volume (Vglom) in kidneys of healthy wild-type mice and mice with oligosyndactylism (Os/+), a model of congenital nephron reduction. Mice were injected with CF and perfused, and the resected kidneys were imaged with 7T MRI to detect CF-labeled glomeruli. CFE-MRI was used to measure the intrarenal distribution of individual glomerular volumes and revealed two major populations of glomeruli distinguished by size. Spatial mapping revealed that the largest glomeruli were located in the juxtamedullary region in both wild-type and Os/+ mice and the smallest population located in the cortex. Os/+ mice had about a 50% reduction and 35% increase of Nglom and Vglom, respectively, in both glomerular populations compared with wild type, consistent with glomerular hypertrophy in the Os/+ mice. Thus, we provide a foundation for whole-kidney, MRI-based phenotyping of mouse renal glomerular morphology and provide new potential for quantitative human renal diagnostics.


Subject(s)
Disease Models, Animal , Kidney/abnormalities , Magnetic Resonance Imaging/methods , Animals , Male , Mice , Mice, Inbred C57BL
19.
Contrast Media Mol Imaging ; 9(5): 323-32, 2014.
Article in English | MEDLINE | ID: mdl-24764110

ABSTRACT

Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have limited in vivo detection due to a number of constraints with T2 or T2*-weighted imaging. T1-weighted imaging is often preferred for molecular MRI, but most T1-shortening agents are small chelates with low metal payload or are nanoparticles that also shorten T2 and limit the range of concentrations detectable with T1-weighting. Here we used tungsten and iron deposition to form doped iron oxide crystals inside the apoferritin cavity to form a WFe nanoparticle with a disordered crystal and un-coupled atomic magnetic moments. The atomic magnetic moments were thus localized, resulting in a principally paramagnetic nanoparticle. The WFe nanoparticles had no coercivity or saturation magnetization at 5 K and sweeping up to ± 20,000 Oe, while native ferritin had a coercivity of 3000 Oe and saturation at ± 20,000 Oe. This tungsten-iron crystal paramagnetism resulted in an increased WFe particle longitudinal relaxivity (r1) of 4870 mm(-1) s(-1) and a reduced transverse relaxivity (r2) of 9076 mm(-1) s(-1) compared with native ferritin. The accumulation of the particles was detected with T1-weighted MRI in concentrations from 20 to 400 nm in vivo, both injected in the rat brain and targeted to the rat kidney glomerulus. The WFe apoferritin nanoparticles were not cytotoxic up to 700 nm particle concentrations, making them potentially important for targeted molecular MRI.


Subject(s)
Contrast Media/chemistry , Ferric Compounds/chemistry , Magnetic Resonance Imaging/methods , Magnetite Nanoparticles/chemistry , Animals , Ferritins/chemistry , Humans , Rats
20.
Am J Physiol Renal Physiol ; 306(11): F1381-90, 2014 Jun 01.
Article in English | MEDLINE | ID: mdl-24647716

ABSTRACT

Nephron number (N(glom)) and size (V(glom)) are correlated with risk for chronic cardiovascular and kidney disease and may be predictive of renal allograft viability. Unfortunately, there are no techniques to assess N(glom) and V(glom) in intact kidneys. This work demonstrates the use of cationized ferritin (CF) as a magnetic resonance imaging (MRI) contrast agent to measure N(glom) and V(glom) in viable human kidneys donated to science. The kidneys were obtained from patients with varying levels of cardiovascular and renal disease. CF was intravenously injected into three viable human kidneys. A fourth control kidney was perfused with saline. After fixation, immunofluorescence and electron microscopy confirmed binding of CF to the glomerulus. The intact kidneys were imaged with three-dimensional MRI and CF-labeled glomeruli appeared as punctate spots. Custom software identified, counted, and measured the apparent volumes of CF-labeled glomeruli, with an ~6% false positive rate. These measurements were comparable to stereological estimates. The MRI-based technique yielded a novel whole kidney distribution of glomerular volumes. Histopathology demonstrated that the distribution of CF-labeled glomeruli may be predictive of glomerular and vascular disease. Variations in CF distribution were quantified using image texture analyses, which be a useful marker of glomerular sclerosis. This is the first report of direct measurement of glomerular number and volume in intact human kidneys.


Subject(s)
Kidney Diseases/pathology , Kidney Glomerulus/pathology , Kidney/pathology , Magnetic Resonance Imaging/methods , Adult , Aged , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...