Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Coron Artery Dis ; 22(1): 92-5, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21150779

ABSTRACT

BACKGROUND: The relationship of the ischemic time to primary angioplasty and the quality of myocardial reperfusion according to infarcted territory among patients with ST-segment elevation myocardial infarction (STEMI) is unclear. METHODS: This study consisted of 140 patients with STEMI within 12 h from the symptom onset and undergoing a primary angioplasty from the Protection of Distal Embolization in High-Risk Patients with Acute ST-Segment Elevation Myocardial Infarction Trial. ST-segment resolution (STR) at 60 min was analyzed by an independent corelab using continuous ST monitoring. Patients were divided according to anterior (n=74) and nonanterior (n=64) locations and according to ischemic time in quartiles (<90, 90-148, 148-241, and 241-635 min). RESULTS: Although there was no significant decrement in the extent of STR with the ischemic time in the entire population (74, 51, 72, and 51%, respectively, P=not significant), patients with anterior location have a significant reduction in the extent of STR after 90 min compared with those coming after 90 min (70.6 vs. 29.2% of complete STR, P=0.003, respectively). CONCLUSION: Patients with anterior STEMI seem to have a stronger impact of ischemic time on the quality of myocardial reperfusion compared with patients with nonanterior location.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Circulation , Myocardial Infarction/therapy , Myocardial Ischemia/therapy , Myocardial Reperfusion , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/mortality , Chi-Square Distribution , Coronary Angiography , Electrocardiography , Embolic Protection Devices , Female , Heart Failure/etiology , Humans , Logistic Models , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Myocardial Infarction/physiopathology , Myocardial Ischemia/complications , Myocardial Ischemia/diagnostic imaging , Myocardial Ischemia/mortality , Myocardial Ischemia/physiopathology , Myocardial Reperfusion/adverse effects , Myocardial Reperfusion/instrumentation , Myocardial Reperfusion/mortality , Odds Ratio , Prospective Studies , Recurrence , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
2.
J Invasive Cardiol ; 17(12): 663-6, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16327050

ABSTRACT

OBJECTIVE: To report the safety and feasibility of a new occluding thermographic catheter in patients with coronary artery disease. BACKGROUND: Although plaque temperature heterogeneity is shown in atheromatous plaques, significant underestimation is encountered due to the cooling effect of the uninterrupted blood flow. METHODS: The catheter was positioned at the stenotic site. Blood flow was interrupted by an expandable braid located at the distal portion of the catheter. Then, thermographic assessment was performed. RESULTS: In one patient, the catheter could not reach the lesion due to tortuosity. Of the 20 lesions evaluated, 5 were excluded due to unsuccessful interruption of blood flow. We identified 5 lesions with a 0.3 degrees Celcius elevations compared to the same site without interruption of blood flow. There were no procedural complications. CONCLUSION: The new catheter-occluding thermographic device, while avoiding the blood flow cooling effect, appears to be safe and feasible for the assessment of human plaque temperature heterogeneity.


Subject(s)
Catheterization/adverse effects , Coronary Artery Disease/diagnosis , Thermography/instrumentation , Aged , Body Temperature , Coronary Artery Disease/blood , Coronary Artery Disease/physiopathology , Coronary Circulation , Equipment Design , Feasibility Studies , Female , Humans , Male , Middle Aged , Safety
3.
Coron Artery Dis ; 16(5): 327-30, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16000892

ABSTRACT

BACKGROUND: Although target lesion revascularization (TLR) has been dramatically decreased by using drug-eluting stents (DESs) in de-novo lesions, their efficacy for in-stent restenosis (ISR) has not yet been well established. METHODS: We retrospectively analysed patients treated for ISR with DESs from three referral hospitals. RESULTS: Eighty-seven consecutive patients, from June 2002 to April 2004, were included, with a mean age of 64+/-11 years; 83% were men, 32% had diabetes, 47% had had a previous myocardial infarction and 16% had low left ventricular ejection fraction. Angiographic characteristics were as follows: mean vessel diameter, 3.05+/-0.4 mm; lesion length, 17.8+/-7.7 mm; diameter stenosis, 84.0+/-10.7%; and complex lesion, 81%. The restenosis was focal in 45%, diffuse/proliferative in 51.3% and total occlusion in 3.7% of the cases. Sirolimus- and paclitaxel-eluting stents were used in 42 and 58% of the patients, respectively. Stent diameter was 3.1+/-0.3 mm and the length was 26.1+/-5.8 mm. Angiographic success was achieved in all patients, with one patient experiencing a post-procedural non-Q-wave myocardial infarction. At 6-month clinical follow-up, two patients had died from non-cardiac deaths, five had experienced a new TLR (5.7%, four percutaneous and one coronary artery bypass graft) and eight (9.2%) had had major adverse cardiac events. A stress test was performed in 60% of the population; target vessel ischemia was observed in one patient (3.3%). CONCLUSION: In this non-select cohort of patients, the use of DESs is a safe and effective strategy for ISR lesions.


Subject(s)
Coated Materials, Biocompatible/therapeutic use , Coronary Restenosis/therapy , Stents , Aged , Blood Vessel Prosthesis Implantation/methods , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/therapeutic use , Male , Middle Aged , Myocardial Infarction/therapy , Paclitaxel/therapeutic use , Practice Patterns, Physicians' , Retrospective Studies , Sirolimus/therapeutic use , Survival Analysis , Treatment Outcome , Ventricular Dysfunction, Left/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...