Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 107
Filter
1.
Innovations (Phila) ; : 15569845241252170, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38835206

ABSTRACT

OBJECTIVE: There can be anatomical constraints on patient selection for minimally invasive surgery. For example, robot-assisted coronary artery bypass was reported to be more challenging when patients had a cardiothoracic ratio >50% and a sternum-vertebra anteroposterior and transverse diameter ratio <0.45. We sought to examine the impact of chest wall anatomic parameters on surgical outcomes in our totally endoscopic coronary artery bypass (TECAB) procedures. METHODS: We retrospectively reviewed patients who underwent robotic TECAB, all of whom had a preoperative chest radiograph at our institution from July 2017 to October 2021. The cohort was divided into 2 groups, which were patients undergoing single-vessel grafting using the left internal thoracic artery (ITA; group 1) and patients undergoing multivessel grafting with bilateral ITA grafts (group 2). We measured several anatomical parameters from the preoperative chest radiograph. RESULTS: A total of 352 patients undergoing TECAB were retrospectively analyzed. After exclusions, 193 were included in this study. In group 1 (n = 91), no parameters correlated with operative time. In group 2 (n = 102), a significant negative correlation was observed between operative time and the sternum-vertebrae anteroposterior diameter (rs = -0.228, P = 0.022) and lung anteroposterior diameter (rs = -0.246, P = 0.013). To confirm these results in group 2, a propensity-matched analysis was performed and showed a statistically significant difference in surgical time based on chest anteroposterior diameters. CONCLUSIONS: In single-vessel robotic TECAB, chest wall anatomic dimensions measured on chest radiograph did not affect operative time. In multivessel cases with bilateral ITA grafts, larger anteroposterior diameter correlated with shorter operative times.

4.
Innovations (Phila) ; 19(2): 192-195, 2024.
Article in English | MEDLINE | ID: mdl-38606852

ABSTRACT

OBJECTIVE: Femoral artery cannulation is the most commonly used approach for cardiopulmonary bypass (CPB) in robotic cardiac procedures. However, without adding a distal perfusion cannula, leg ischemia can occur in up to 11.5% of patients. There is a well-described 2 to 4 mm size arterial branch that originates from the medial side of the external iliac artery or inferior epigastric artery, immediately above the inguinal ligament, and connects to the obturator artery. Therefore, it was historically named the corona mortis, which means "crown of death" in Latin. When peripheral cannulation is performed above this branch in the external iliac artery, we consider it a corona "vitae" because of its role as a limb-saving collateral. We report herein our standard technique of peripheral cannulation without the need of a distal perfusion cannula and preventing limb ischemia. METHODS: We included all patients who underwent robotic cardiac surgery with peripheral cannulation over a 16-month period at our institution. We cannulated just above the level of the inguinal ligament through a 2 to 3 cm transverse skin incision. The incidence of limb ischemia and vascular complications was recorded and analyzed. RESULTS: During the study period, 133 patients underwent robotic cardiac procedures with peripheral "external iliac" CPB. The size of the cannula was 21F or larger in 73% and 23F in 54% of the patients. No leg ischemia or femoral artery complications requiring additional intervention occurred. CONCLUSIONS: External iliac cannulation can be successfully performed in robot-assisted cardiac surgery using relatively large cannulas without the need of a distal limb perfusion catheter, with good results. In our view, given the importance of the corona mortis ("crown of death" in Latin) in perfusing the limb during CPB, we propose a new name for this artery in robotic cardiac surgery, namely, the corona vitae ("crown of life" in Latin).


Subject(s)
Iliac Artery , Robotic Surgical Procedures , Humans , Iliac Artery/surgery , Robotic Surgical Procedures/methods , Male , Female , Aged , Cardiac Surgical Procedures/methods , Cardiopulmonary Bypass/methods , Middle Aged , Ischemia/prevention & control , Catheterization, Peripheral/methods , Femoral Artery/surgery , Catheterization/methods
7.
Semin Thorac Cardiovasc Surg ; 36(1): 27-36, 2024.
Article in English | MEDLINE | ID: mdl-36921680

ABSTRACT

We compare outcomes of endo-aortic balloon occlusion (EABO) vs external aortic clamping (EAC) in patients undergoing minimally invasive mitral valve surgery (MIMVS) in the Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database. Adults undergoing mitral valve surgery (July 2017-December 2018) were identified within the STS database (N = 60,607). Total 7,978 patients underwent a minimally invasive approach (including robotically assisted). About 1,163 EABO patients were 1:1 propensity-matched to EAC patients using exact matching on age, sex, and type of mitral procedure, and propensity score average matching for 16 other risk indicators. Early outcomes were compared. Categorical variables were compared using logistic regression; hospital and intensive care unit length of stay were compared using negative binomial regression. In the matched cohort, mean age was 62 years; 35.9% were female, and 86% underwent mitral valve repair. Cardiopulmonary bypass time was shorter for EABO vs EAC group (125.0 ± 53.0 vs 134.0 ± 67.0 minutes, P = 0.0009). There was one aortic dissection in the EAC group and none in the EABO group (P value > 0.31), and no statistically significant differences in cross-clamp time, major intraoperative bleeding, perioperative mortality, stroke, new onset of atrial fibrillation, postoperative acute kidney injury, success of repair. Median hospital LOS was shorter for EABO vs EAC procedures (4 vs 5 days, P < 0.0001). In this large, retrospective, STS database propensity-matched analysis ofpatients undergoing MIMVS, we observed similar safety outcomes for EABO and EAC, including no aortic dissections in the EABO group. The EABO group showed slightly shorter CPB times and hospital LOS.


Subject(s)
Balloon Occlusion , Cardiac Surgical Procedures , Adult , Humans , Female , Middle Aged , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Retrospective Studies , Constriction , Treatment Outcome , Minimally Invasive Surgical Procedures/methods
8.
Innovations (Phila) ; 18(5): 419-423, 2023.
Article in English | MEDLINE | ID: mdl-37753828

ABSTRACT

OBJECTIVE: Robotic totally endoscopic coronary artery bypass (TECAB) grafting is the least invasive form of coronary bypass surgery. However, despite its advantages, this approach has not gained widespread adoption. One possible reason is the advanced and complex robotic skills required to execute a totally endoscopic sutured coronary anastomosis. We prepared a novel, inexpensive, easy to set up robotic TECAB simulator. METHODS: A pig heart was placed in a cardboard box, and 3 holes were made on the side to mimic the exposure and surgical ergonomics of TECAB port placement. Four robotic ports were placed and docked to the da Vinci Si robot (Intuitive Surgical, Sunnyvale, CA, USA). Monofilament 7:0 suture (7 cm long) was used to perform the anastomosis to the left anterior descending artery using remnant conduit. Seven cardiac surgeons of various training levels participated and were asked to fill out a 10-point questionnaire. RESULTS: The cost of the simulator totaled $20 per session, with 20 min to assemble. Each session allowed each trainee to practice 3 to 4 coronary anastomoses. Three cardiac surgeons completed the survey and strongly agreed that the model was easy to set up, the anastomotic exercise was realistic, and that this practice helped them gain confidence. CONCLUSIONS: Our TECAB simulator is inexpensive, easy to set up, and allows trainees to practice endoscopic coronary suturing. We believe this to be a valuable training tool to learn how to do TECAB for established surgeons and that such a simulator may be of great value to cardiothoracic training programs and their trainees. Further studies are warranted.

10.
Radiol Case Rep ; 18(10): 3544-3548, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37547798

ABSTRACT

Aortic regurgitation (AR) represents a significant cause of morbidity and mortality. Due to its low cost and widespread availability, echocardiography remains the frontline for aortic valve (AV) assessment. However, poor sonographic windows may limit the assessment of valve morphology with this technique. Cardiovascular computed tomography (CCT) is increasingly utilized prior to structural AV interventions. Due to its excellent spatial resolution, CCT provides exceptional characterization of aortic leaflets. Accordingly, we present a case of a quadricuspid valve diagnosed by CCT. Here, CCT led to a new diagnosis of quadricuspid valve, highlighting the potential for CCT for the characterization of aortic leaflet morphology. CCT may be particularly useful in patients with contraindications to transesophageal echocardiography or those undergoing structural or robotic interventions.

11.
Innovations (Phila) ; 18(4): 346-351, 2023.
Article in English | MEDLINE | ID: mdl-37458227

ABSTRACT

OBJECTIVE: The standard management of concomitant aortic valve (AV) and coronary artery disease has been coronary artery bypass and AV replacement (AVR). With the advent of minimally invasive options, many isolated lesions have been successfully managed using a sternal-sparing approach. In our institution, patients with isolated AV disease are offered minimally invasive surgical or transcatheter AVR, and those with isolated coronary artery disease are routinely managed with robotic totally endoscopic coronary artery bypass or percutaneous coronary intervention. Various combinations of these techniques can be used when a sternal-sparing posture is desired because of patient risk or preference. The aim of this study was to review the outcomes in patients with combined AV and coronary disease who were managed using sternal-sparing approaches. METHODS: We reviewed the records of 10 patients in our minimally invasive surgical database who presented with concomitant AV and coronary artery disease and underwent combined sternal-sparing management of these 2 lesions using various combinations of minimally invasive approaches. RESULTS: Four patients had totally endoscopic coronary artery bypass and minimally invasive AVR at the same time, 2 patients underwent transcatheter AVR followed by totally endoscopic coronary artery bypass, and 4 patients underwent minimally invasive AVR with percutaneous coronary intervention. There was no 30-day mortality. The duration of postoperative surgical hospital stay was 3.1 ± 0.9 days. CONCLUSIONS: Sternal-sparing approaches in combined AV and coronary artery disease are feasible with patient-specific treatment selection of minimally invasive techniques.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Heart Valve Prosthesis Implantation , Humans , Aortic Valve/surgery , Coronary Artery Disease/complications , Coronary Artery Disease/surgery , Coronary Artery Bypass/methods , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Retrospective Studies
12.
Innovations (Phila) ; 18(4): 338-345, 2023.
Article in English | MEDLINE | ID: mdl-37458243

ABSTRACT

OBJECTIVE: Endoaortic balloon occlusion facilitates cardioplegic arrest during minimally invasive surgery (MIS). Studies have shown endoclamping to be as safe as traditional aortic clamping. We compared outcomes and hospital costs of endoclamping versus external aortic occlusion in a large administrative database. METHODS: There were 52,882 adults undergoing eligible cardiac surgery (October 2015 to March 2020) identified in the Premier Healthcare Database. Endoclamp procedures (n = 419) were 1:3 propensity score matched to similar procedures using external aortic occlusion (n = 1,244). Generalized linear modeling measured differences in in-hospital complications (major adverse renal and cardiac events, including mortality, new-onset atrial fibrillation, acute kidney injury [AKI], myocardial infarction [MI], postcardiotomy syndrome, stroke/transient ischemic attack [TIA], and aortic dissection) and length of stay (LOS). RESULTS: The mean age was 63 years, and 53% were male (n = 882). The majority (93%, n = 1,543) were mitral valve procedures, and 17% of procedures (n = 285) were robot-assisted. Total hospitalization costs were not statistically significantly different between the 2 groups ($52,158 vs $49,839, P = 0.06). The median LOS was significantly shorter in the endoclamp group (incident rate ratio = 0.87, P < 0.001). Mortality, atrial fibrillation, AKI, and stroke/TIA were similar between the 2 groups. MI and postcardiotomy syndrome were lower in the endoclamp group (odds ratio [OR] = 0.14, P = 0.006, and OR = 0.27, P = 0.005). There were no aortic dissections in the endoclamp group. CONCLUSIONS: Aortic endoclamping in MIS was associated with similar costs, shorter LOS, no dissections, and comparably low mortality and stroke rates when compared with external clamping in this hospital billing dataset. These results demonstrate the clinical safety and efficacy of endoaortic balloon clamping in a real-world setting. Further studies are warranted.


Subject(s)
Acute Kidney Injury , Atrial Fibrillation , Cardiac Surgical Procedures , Ischemic Attack, Transient , Myocardial Infarction , Stroke , Adult , Humans , Male , Middle Aged , Female , Ischemic Attack, Transient/etiology , Cardiac Surgical Procedures/methods , Minimally Invasive Surgical Procedures/adverse effects , Minimally Invasive Surgical Procedures/methods , Stroke/epidemiology , Stroke/etiology , Acute Kidney Injury/etiology , Treatment Outcome , Retrospective Studies
13.
J Surg Res ; 291: 139-150, 2023 11.
Article in English | MEDLINE | ID: mdl-37390593

ABSTRACT

INTRODUCTION: The left internal thoracic artery (LITA) is most commonly used to bypass the left anterior descending artery (LAD) given its well-established mortality benefit. In some cases, the grafting strategy necessitates placing the right internal thoracic artery (RITA) on the LAD. We compared outcomes in our robotic beating-heart totally endoscopic coronary bypass surgery (TECAB) population between patients receiving LITA versus RITA-LAD grafts. METHODS: We retrospectively reviewed patients undergoing robotic TECAB with skeletonized ITA conduits over 9 y. Outcomes were compared between those receiving LITA (Group-1) versus RITA (Group-2) grafts to the LAD (with/without other grafts). End points were early angiographic patency (in patients undergoing hybrid revascularization) and mid-term mortality/major adverse cardiac/cerebrovascular events. A propensity matched subanalysis was performed comparing only patients who received bilateral ITA grafting in each group. RESULTS: Society of Thoracic Surgeons predicted mortality risk score was higher in Group-2. Group-1 patients had lower incidence of multivessel disease (75% versus 96%, P ≤ 0.001). Early overall graft patency (97% versus 96%, P = 0.718) and LAD graft patency (98% versus 95%, P = 0.372) were equivalent. At mean 42-mo follow-up (longest 8.5 y), Group-1 had lower all-cause mortality but no difference in cardiac mortality or repeat revascularization. In the propensity matched subanalysis, mid-term outcomes were equivalent. CONCLUSIONS: Grafting the LAD with the LITA or RITA during robotic beating-heart TECAB resulted in similar early outcomes and angiographic patency. RITA-LAD patients were more likely to have multivessel disease and higher Society of Thoracic Surgeons risk and had higher all-cause mortality at mid-term analysis but no difference in major adverse cardiac/cerebrovascular events, including cardiac mortality.


Subject(s)
Coronary Artery Disease , Mammary Arteries , Robotic Surgical Procedures , Humans , Mammary Arteries/transplantation , Retrospective Studies , Robotic Surgical Procedures/adverse effects , Treatment Outcome , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/methods , Vascular Patency , Coronary Artery Disease/surgery
14.
Innovations (Phila) ; 18(2): 159-166, 2023.
Article in English | MEDLINE | ID: mdl-37029651

ABSTRACT

OBJECTIVE: The benefits of Enhanced Recovery After Surgery (ERAS) protocols are being recognized in multiple surgical specialties, including following coronary bypass surgery to improve quality of care and decrease costs. We developed a fast-track discharge protocol for patients undergoing robotic totally endoscopic coronary bypass surgery (TECAB) to be discharged on postoperative day (POD) 1, the subjects of this study. METHODS: In a retrospective study of 720 patients undergoing robotic beating-heart TECAB over 8 years at our institution, 93 patients were selected for a fast-track POD1 discharge protocol. We compared the outcomes of this group to the remaining 627 patients who were discharged per standard protocol (non-POD1 discharge). RESULTS: The early discharge group was significantly younger, had lower Society of Thoracic Surgeons (STS) risk of mortality, and had a lower prevalence of obesity, diabetes, and chronic kidney disease. Patients discharged on POD1 were more often extubated in the operating room (56% vs 42%, P = 0.010). The readmission rate for the early discharge group was 3.2%, which was similar to the readmission rate of 6.7% for the standard discharge protocol group (P = 0.329). Time to return to work was shorter in the early discharge group, although it did not quite reach statistical significance (12 vs 18 days, P = 0.051). There was no difference in midterm cardiac mortality. CONCLUSIONS: Early discharge on POD1 after robotic TECAB is appropriate in selected patients and is associated with low readmission rates and a trend towards earlier return to work. Patients suitable for this "ultrafast-track" approach were more likely to be younger, have lower STS risk, and fewer comorbidities.


Subject(s)
Coronary Artery Disease , Enhanced Recovery After Surgery , Robotic Surgical Procedures , Humans , Patient Discharge , Robotic Surgical Procedures/methods , Retrospective Studies , Coronary Artery Bypass/methods , Endoscopy/methods , Treatment Outcome , Coronary Artery Disease/surgery
18.
Braz J Cardiovasc Surg ; 38(3): 407-410, 2023 05 04.
Article in English | MEDLINE | ID: mdl-36692050

ABSTRACT

In the setting of minimally invasive and robotic-assisted intracardiac procedures, de-airing requires further technical considerations due to limited access to the pericardial space and the subsequent difficulty of directly manipulating the heart. We summarize the technical steps for de-airing according to different cannulation strategies for minimally invasive and robotic-assisted intracardiac procedures.


Subject(s)
Robotic Surgical Procedures , Humans , Minimally Invasive Surgical Procedures/methods , Heart
19.
J Thorac Cardiovasc Surg ; 166(3): 805-815.e1, 2023 09.
Article in English | MEDLINE | ID: mdl-35525802

ABSTRACT

OBJECTIVE: A number of publicly available rating algorithms are used to assess hospital performance in coronary artery bypass grafting (CABG). However, concerns remain that these algorithms fail to correlate with each other and inadequately capture the case complexity of individual center practices. METHODS: Composite star ratings for isolated CABG from the Society of Thoracic Surgeons public reporting database were extracted for 2018-2019. U.S. News & World Report Best Hospitals was used to extract CABG ratings as well as overall cardiology and heart surgery ranking, and the Centers for Medicare & Medicaid Services Hospital Compare was used to extract CABG volume and 30-day mortality. Spearman correlation coefficients were used to assess possible relationships. Expert opinion on risk adjustment and program evaluation was incorporated. RESULTS: Correlations between Society of Thoracic Surgeons star rating and U.S. News & World Report overall ranking in cardiology and heart surgery (r = 0.15) and Centers for Medicare & Medicaid Services 30-day mortality (r = -0.27) were poor. Society of Thoracic Surgeons star rating correlated weakly with U.S. News & World Report CABG ratings (r = 0.33) and with Centers for Medicare & Medicaid Services CABG volume (r = 0.32), whereas the latter 2 correlated moderately (r = 0.52) with each other. Of the 75 centers with accredited cardiac surgery training programs, 13 (17%) did not participate in Society of Thoracic Surgeons public reporting. Important gaps were identified in risk assessment, and potential solutions are proposed. CONCLUSIONS: Correlations between current CABG public reporting systems are weak. Further work is needed to refine and standardize CABG rating systems to more adequately capture the scope and complexity of an individual center's clinical practice and to better inform patients.


Subject(s)
Cardiac Surgical Procedures , Medicare , Humans , Aged , United States , Coronary Artery Bypass/adverse effects , Hospitals , Risk Adjustment
SELECTION OF CITATIONS
SEARCH DETAIL
...