Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Infect Control Hosp Epidemiol ; 45(4): 405-411, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38204365

ABSTRACT

Diagnostic stewardship seeks to improve ordering, collection, performance, and reporting of tests. Test results play an important role in reportable HAIs. The inclusion of HAIs in public reporting and pay for performance programs has highlighted the value of diagnostic stewardship as part of infection prevention initiatives. Inappropriate testing should be discouraged, and approaches that seek to alter testing solely to impact a reportable metric should be avoided. HAI definitions should be further adapted to new testing technologies, with focus on actionable and clinically relevant test results that will improve patient care.


Subject(s)
Cross Infection , Reimbursement, Incentive , Humans , Cross Infection/diagnosis , Cross Infection/prevention & control , Surveys and Questionnaires , Benchmarking , Delivery of Health Care
2.
J Clin Microbiol ; 40(7): 2331-4, 2002 Jul.
Article in English | MEDLINE | ID: mdl-12089243

ABSTRACT

Exploiting the high sensitivity of the chemiluminescence phenomenon, an accurate and sensitive point-of-care test, called the ZstatFlu-II test (ZymeTx, Inc., Oklahoma City, Okla.), was developed to detect influenza virus infections. The ZstatFlu-II test takes 20 min and requires approximately 2 min of "hands-on" time for operational steps. The ZstatFlu-II test does not distinguish between infections with influenza virus types A and B. ZstatFlu-II test results are printed on Polaroid High-Speed Detector Film, allowing test results to be archived. A prototype version of the ZstatFlu-II test was evaluated during the 2000-to-2001 flu season with 300 nasal aspirate specimens from children at a pediatric hospital. Compared to culture, the ZstatFlu-II test had 88% sensitivity and 92% specificity. The Directigen test had a sensitivity of 75% and a specificity of 93%. The sensitivity of the ZstatFlu-II test was significantly higher than that of the Directigen test (P < 0.0574).


Subject(s)
Influenza, Human/diagnosis , Luminescent Measurements , Orthomyxoviridae/isolation & purification , Virology/methods , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Influenza, Human/virology , Male , Microbiological Techniques , Sensitivity and Specificity , Virology/statistics & numerical data , Virus Cultivation
SELECTION OF CITATIONS
SEARCH DETAIL
...