Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Acta Chir Belg ; 122(2): 99-106, 2022 Apr.
Article in English | MEDLINE | ID: mdl-33571418

ABSTRACT

OBJECTIVE: The Maze IV (M-IV) procedure is regarded as the golden standard in treatment for surgical ablation of atrial fibrillation (AF); however, long-term follow-up results are scarce. We present our institutional 10-year experience. METHODS: We collected data of 117 consecutive patients who have undergone a concomitant M-IV procedure between April 2006 and April 2016. Primary endpoints are freedom of atrial arrhythmias and freedom of atrial arrhythmias off antiarrhythmic drugs (AAD). RESULTS: Forty-seven patients (40.2%) had paroxysmal AF. Two-thirds of the procedures included mitral valve surgery. The average follow-up time per patient was 3.8 years (SD 2.8). Freedom of AF at 1 year was 79%, at 5 years freedom of AF was 69% and freedom of AF off AAD was 56%. Predictors of AF recurrence in multivariate analysis were age, preoperative pacemakers, redo cardiac surgery and in-hospital AF. Preoperative PVI ablation was found to be a protective factor. CONCLUSIONS: The long-term outcomes of the M-IV procedure are good and remain stable over the years. Results could be improved if follow-up were to be intensified and recurrences dealt with aggressively. Key question: How many patients are free from AF in a 10-year period after concomitant M-IV surgical ablation? Key findings: In the long term around 70% of patients are free of AF with an increasing need for anti-arrhythmic drugs. Take home message: Early to midterm freedom from AF after concomitant M-IV procedure is high and remains stable after 3 years.


Subject(s)
Atrial Fibrillation , Cardiac Surgical Procedures , Catheter Ablation , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/methods , Catheter Ablation/methods , Humans , Maze Procedure , Treatment Outcome
2.
Int Wound J ; 15(2): 198-204, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29430829

ABSTRACT

The objective is to describe the 'Two Bridges Technique' (TBT), which has proven to be successful and has been the standard technique at our centre for vacuum-assisted closure (VAC) of post-sternotomy mediastinitis. An extensive literature search was performed in four databases to identify all published articles concerning VAC for post-sternotomy mediastinitis. Several VAC methods have been used; however, no article has described our specific technique. TBT consists of a two-bridges construction using two types of foam with different pore sizes, which ensures an equally divided negative pressure over the wound bed and stabilisation of the chest. This guarantees a continuous treatment of the sternal defect and prevents foam displacement. It maintains an airtight seal that prevents skin maceration and provides enough protection to avoid right ventricular rupture. The main advantage of TBT is the prevention of shifting or tilting of the foam during chest movements such as breathing or couching. Along with targeted antibiotic treatment, this alternative VAC technique can be an asset in the sometimes cumbersome treatment of post-sternotomy mediastinitis.


Subject(s)
Mediastinitis/therapy , Negative-Pressure Wound Therapy/methods , Sternotomy/methods , Sternum/surgery , Surgical Wound Infection/prevention & control , Wound Closure Techniques , Wound Healing/physiology , Female , Humans , Male
3.
Acta Chir Belg ; 116(6): 383-385, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27472167

ABSTRACT

Ventricular septal rupture (VSR) occurs in approximately 1% of the patients who experience an acute myocardial infarction. The operative mortality of VSR repair decreases if surgery can be delayed until the infarct has healed and tissue strength improved. Because of heart failure or impending cardiogenic shock, surgical treatment can often not be delayed. We present a case in which a delayed repair of a VSR was possible. The patient was initially stabilized with an intra-aortic balloon pump. She was discharged and readmitted 5 weeks later for definitive repair. Repair was performed, according to the Daggett technique, using a bovine pericardial patch and a mitral annuloplasty was carried out to correct for the regurgitation. Recovery was uneventful. Cardiac ultrasound examination at discharge showed no residual defect.


Subject(s)
Cardiac Surgical Procedures/methods , Ventricular Septal Rupture/surgery , Echocardiography , Female , Humans , Middle Aged , Time Factors , Ventricular Septal Rupture/diagnosis
4.
Interact Cardiovasc Thorac Surg ; 7(2): 201-6, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18045831

ABSTRACT

Different lesion sets and ablation techniques have been performed. We compared these outcomes in search of the best method. We performed a retrospective analysis of patients who have undergone AF surgery different from the maze III. The surgical lesion sets were pulmonary vein isolation (PVI) alone, left atrial maze (LAM) and bi-atrial maze (BAM) and were made with different ablation techniques. During surgery one patient died due to bleeding of a pulmonary vein. The number of patients in the PVI-, LAM-, BAM-groups was 12, 28 and 26, respectively, with freedom from AF at latest follow-up [22.0+/-15.6 (3.1-81.2) months] of 33%, 59% and 60%, respectively. Atrial flutter occurred less in the BAM-group (4%) than in the left-sided procedures (15.4%) (P=0.231). Multivariate analysis demonstrated a higher recurrence of AF for PVI alone (OR 4.42, CL 0.95-20.6, P=0.0583) and a lower recurrence for the 'cut-and-sew' technique (OR 0.13, CL 0.030-0.60, P=0.0084). Left- and bi-atrial maze procedures are equally effective in the suppression of AF, whereas omission of right-sided lesions results in a higher prevalence of atrial flutter. The 'cut-and-sew' technique is superior in terms of freedom from AF compared to bipolar and unipolar radiofrequency.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Aged , Atrial Appendage/surgery , Atrial Fibrillation/mortality , Atrial Flutter/etiology , Catheter Ablation/adverse effects , Female , Follow-Up Studies , Humans , Male , Middle Aged , Odds Ratio , Pulmonary Veins/surgery , Recurrence , Research Design , Retrospective Studies , Risk Assessment , Time Factors , Treatment Outcome
5.
J Thorac Cardiovasc Surg ; 132(6): 1433-40, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17140972

ABSTRACT

OBJECTIVES: We studied the persistence of favorable outcome, the occurrence of new atrial arrhythmias, and sinus node dysfunction in patients who underwent the maze III procedure. METHODS: Preoperative, in-hospital, and follow-up data of 203 patients who underwent the maze III procedure between June 1993 and June 2003 were collected. A total of 139 patients underwent the maze procedure for lone atrial fibrillation, and 64 patients underwent the maze procedure and concomitant cardiac surgery. RESULTS: There was no 30-day postoperative mortality. During a mean follow-up of 4.0 +/- 2.6 years, 12 patients (6%) died (2 cardiac related). At the end of follow-up, freedom from supraventricular arrhythmias was 80% for the lone atrial fibrillation group and 64% for the concomitant atrial fibrillation group. Freedom from stroke during follow-up was 100% in the lone atrial fibrillation group and 97% in the concomitant group. Multivariate analysis revealed that rhythm at 1-year follow-up (P < .001; odds ratio 9.56, 95% confidence limits 3.92-23.31) and preoperative left atrium dimension (P = .028; odds ratio 1.06 for every millimeter, 95% confidence limits 1.01-1.12) were predictors of success at the end of follow-up. CONCLUSIONS: This study shows that the favorable results of the maze III procedure in terms of freedom from supraventricular arrhythmias persist in most patients for at least 4 years.


Subject(s)
Arrhythmias, Cardiac/surgery , Cardiac Surgical Procedures/methods , Female , Follow-Up Studies , Heart Atria , Humans , Male , Middle Aged , Remission Induction , Time Factors
6.
Perfusion ; 17(3): 191-8, 2002 May.
Article in English | MEDLINE | ID: mdl-12017387

ABSTRACT

The benefits of pulsatile flow during the period of cardiopulmonary bypass (CPB) applied during open-heart surgery remains controversial. We have developed a rodent (rat) model of CBP that has been designed to functionally mimic the clinical setting, principally, but not solely, for the study of pulsatile CPB. The successful development of this model centres on the design of the bypass circuitry and the surgical approach employed. The entire circuit is similar to clinical equipment in terms of its construction, configuration, performance, material surface area to blood volume ratio, and priming volume to blood volume ratio. The overall priming volume of the perfusion circuitry is less than 12 ml. Early studies confirm that the pumping technology functions well, gas exchange was adequate at all times, and blood pressure exhibited a normal CPB profile and haemodynanmic response to pulsatile blood flow. We conclude that this is an effective tool for investigating the pathophysiology of pulsatile blood flow during CPB.


Subject(s)
Cardiopulmonary Bypass/instrumentation , Cardiopulmonary Bypass/methods , Animals , Blood Pressure , Equipment Design , Hemodilution , Hemodynamics , Male , Oxygenators, Membrane , Pulmonary Gas Exchange , Pulsatile Flow , Rats , Rats, Sprague-Dawley , Reference Values , Regional Blood Flow
SELECTION OF CITATIONS
SEARCH DETAIL
...