Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-35450869

ABSTRACT

INTRODUCTION: People living with diabetes in low-resource settings may be at increased hypoglycemia risk due to food insecurity and limited access to glucose monitoring. We aimed to assess hypoglycemia risk associated with sulphonylurea (SU) and insulin therapy in people living with type 2 diabetes in a low-resource sub-Saharan African setting. RESEARCH DESIGN AND METHODS: This study was conducted in the outpatients' diabetes clinics of two hospitals (one rural and one urban) in Uganda. We used blinded continuous glucose monitoring (CGM) and self-report to compare hypoglycemia rates and duration in 179 type 2 diabetes patients treated with sulphonylureas (n=100) and insulin (n=51) in comparison with those treated with metformin only (n=28). CGM-assessed hypoglycemia was defined as minutes per week below 3mmol/L (54mg/dL) and number of hypoglycemic events below 3.0 mmol/L (54 mg/dL) for at least 15 minutes. RESULTS: CGM recorded hypoglycemia was infrequent in SU-treated participants and did not differ from metformin: median minutes/week of glucose <3 mmol/L were 39.2, 17.0 and 127.5 for metformin, sulphonylurea and insulin, respectively (metformin vs sulphonylurea, p=0.6). Hypoglycemia risk was strongly related to glycated haemoglobin (HbA1c) and fasting glucose, with most episodes occurring in those with tight glycemic control. After adjusting for HbA1c, time <3 mmol/L was 2.1 (95% CI 0.9 to 4.7) and 5.5 (95% CI 2.4 to 12.6) times greater with sulphonylurea and insulin, respectively, than metformin alone. CONCLUSIONS: In a low-resource sub-Saharan African setting, hypoglycemia is infrequent among people with type 2 diabetes receiving sulphonylurea treatment, and the modest excess occurs predominantly in those with tight glycemic control.


Subject(s)
Diabetes Mellitus, Type 2 , Hypoglycemia , Metformin , Blood Glucose , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 2/drug therapy , Glycated Hemoglobin/analysis , Humans , Hypoglycemia/chemically induced , Hypoglycemia/epidemiology , Insulin/adverse effects , Insulin, Regular, Human , Metformin/adverse effects , Sulfonylurea Compounds/adverse effects
2.
Article in English | MEDLINE | ID: mdl-34535465

ABSTRACT

INTRODUCTION: The utility of HbA1c (glycosylated hemoglobin) to estimate glycemic control in populations of African and other low-resource countries has been questioned because of high prevalence of other medical conditions that may affect its reliability. Using continuous glucose monitoring (CGM), we aimed to determine the comparative performance of HbA1c, fasting plasma glucose (FPG) (within 5 hours of a meal) and random non-fasting glucose (RPG) in assessing glycemic burden. RESEARCH DESIGN AND METHODS: We assessed the performance of HbA1c, FPG and RPG in comparison to CGM mean glucose in 192 Ugandan participants with type 2 diabetes. Analysis was undertaken in all participants, and in subgroups with and without medical conditions reported to affect HbA1c reliability. We then assessed the performance of FPG and RPG, and optimal thresholds, in comparison to HbA1c in participants without medical conditions thought to alter HbA1c reliability. RESULTS: 32.8% (63/192) of participants had medical conditions that may affect HbA1c reliability: anemia 9.4% (18/192), sickle cell trait and/or hemoglobin C (HbC) 22.4% (43/192), or renal impairment 6.3% (12/192). Despite high prevalence of medical conditions thought to affect HbA1c reliability, HbA1c had the strongest correlation with CGM measured glucose in day-to-day living (0.88, 95% CI 0.84 to 0.91), followed by FPG (0.82, 95% CI 0.76 to 0.86) and RPG (0.76, 95% CI 0.69 to 0.81). Among participants without conditions thought to affect HbA1c reliability, FPG and RPG had a similar diagnostic performance in identifying poor glycemic control defined by a range of HbA1c thresholds. FPG of ≥7.1 mmol/L and RPG of ≥10.5 mmol/L correctly identified 78.2% and 78.8%, respectively, of patients with an HbA1c of ≥7.0%. CONCLUSIONS: HbA1c is the optimal test for monitoring glucose control even in low-income and middle-income countries where medical conditions that may alter its reliability are prevalent; FPG and RPG are valuable alternatives where HbA1c is not available.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 2 , Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/epidemiology , Glycated Hemoglobin/analysis , Humans , Prevalence , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...