Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Molecules ; 29(14)2024 Jul 11.
Article in English | MEDLINE | ID: mdl-39064866

ABSTRACT

A simple, rapid, and reliable method for detecting harmful gases is urgently required in environmental security fields. In this study, a highly effective cataluminescence sensor based on SiO2/MIL-53(Al) composites was developed to detect trace isobutylaldehyde. The sensor was designed using isobutylaldehyde to generate an interesting cataluminescence phenomenon in SiO2/MIL-53(Al). Under optimized conditions, a positive linear relationship was observed between the signal intensity of the cataluminescence and isobutylaldehyde concentration. The isobutylaldehyde concentration range of 1.55-310 ppm responded well to the sensing test, with an excellent correlation coefficient of 0.9996. The minimum detectable concentration signal-to-noise ratio (S/N = 3) was found to be 0.49 ppm. In addition, the sensor was effectively utilized for analyzing trace isobutylaldehyde; the analysis resulted in recoveries ranging from 83.4% to 105%, with relative standard deviations (RSDs) of 4.8% to 9.4%. Furthermore, the mechanism of cataluminescence between SiO2/MIL-53(Al) and isobutylaldehyde was explored using GC-MS analysis and density functional theory. We expect that this cataluminescence methodology will provide an approach for the environmental monitoring of isobutylaldehyde.