Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Echocardiography ; 26(5): 598-609, 2009 May.
Article in English | MEDLINE | ID: mdl-19438700

ABSTRACT

This case series demonstrates the incremental value of three-dimensional transthoracic echocardiography (3D TTE) over two-dimensional transthoracic echocardiography (2D TTE) in the assessment of 11 patients with right ventricular (RV) masses or mass-like lesions (three cases of RV thrombus, one myxoma, one fibroma, one lipoma, one chordoma, and one sarcoma and three cases of RV noncompaction, which are considered to be mass-like in nature). 3D TTE was of incremental value in the assessment of these masses in that 3D TTE has the capacity to section the mass and view it from multiple angles, giving the examiner a more comprehensive assessment of the mass. This was particularly helpful in the cases of thrombi, as the presence of echolucencies indicated clot lysis. In addition, certainty in the number of thrombi present was an advantage of 3D TTE. Also, sectioning of cardiac tumors allowed more confidence in narrowing the differential diagnosis of the etiology of the mass. In addition, 3D TTE allowed us to identify precise location of the attachments of the masses as well as to determine whether there were mobile components to the mass. Another noteworthy advantage of 3D TTE was that the volumes of the masses could be calculated. Additionally, the findings by 3D TTE correlated well with pathologic examination of RV tumors, and some of the masses measured larger by 3D TTE than by 2D TTE, which was also validated in one case by surgery. As in the case of RV fibroma, another advantage was that 3D TTE actually identified more masses than 2D TTE. RV noncompaction was also well studied, and the assessment with 3D TTE helped to give a more definitive diagnosis in these patients.


Subject(s)
Echocardiography, Three-Dimensional/methods , Heart Neoplasms/diagnostic imaging , Heart Ventricles/diagnostic imaging , Thrombosis/diagnostic imaging , Ventricular Dysfunction, Right/diagnostic imaging , Adult , Computer Systems , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
2.
Echocardiography ; 26(1): 100-6, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19054019

ABSTRACT

We present a case of chronic ascending thoracic aortic dissection with rupture into the right ventricular outflow tract (RVOT) diagnosed by two-dimensional transthoracic echocardiogram in which live/real time three-dimensional (3D) transthoracic echocardiogram provided incremental value by demonstrating: (a) a tortuous false lumen that encroached and ruptured into the RVOT, (b) exact location of the rupture site in relation to other surrounding structures in 3 dimensions (c) en face view of the rupture site facilitating assessment of its size and shape, and (d) localized compression of the main pulmonary artery (PA) by the false lumen. In addition, cropping of the 3D data set permitted visualization of the origin of the left main coronary in a rapid manner excluding involvement of this vessel with the dissection process. These findings have potential implications for surgical planning and were corroborated by a computed tomography angiogram. We summarize seven previously reported aortic dissection cases with rupture into the right ventricle.


Subject(s)
Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Dissection/diagnostic imaging , Aortic Rupture/diagnostic imaging , Echocardiography, Three-Dimensional , Heart Ventricles/diagnostic imaging , Ventricular Outflow Obstruction/diagnostic imaging , Humans , Radiography
3.
Echocardiography ; 25(9): 1004-6, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18771551

ABSTRACT

We report an adult with a discrete subaortic membrane in whom two-dimensional transthoracic Doppler echocardiography demonstrated peak and mean gradients of 64 and 33 mmHg, respectively in the left ventricular outflow tract (LVOT) and a calculated orifice area by continuity equation of 1.14 cm(2) consistent with significant obstruction. However, by direct en face visualization of the LVOT at the level of the membrane by live/real time three-dimensional transthoracic echocardiography (3D TTE), a larger orifice measuring 2.29 cm(2) was seen and was indicative of no significant obstruction. This finding was confirmed at cardiac catheterization, which showed insignificant obstruction.


Subject(s)
Aorta/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Diagnostic Errors/prevention & control , Echocardiography, Doppler/methods , Echocardiography, Three-Dimensional/methods , Echocardiography/methods , Adult , Female , Humans
4.
Echocardiography ; 25(6): 653-7, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18485008

ABSTRACT

We describe a patient with blunt traumatic chest injury in whom three-dimensional transthoracic echocardiography (3DTTE) confirmed the findings of a flail anterior tricuspid valve leaflet and ruptured anterior papillary muscle seen on two-dimensional transthoracic echocardiography, and in addition identified multiple chordae tendinae rupture of the posterior leaflet. Open heart surgery confirmed the findings. The emerging role of 3DTTE in defining the true extent of traumatic tricuspid valvular injury is highlighted.


Subject(s)
Echocardiography, Three-Dimensional/methods , Papillary Muscles/diagnostic imaging , Papillary Muscles/injuries , Thoracic Injuries/diagnostic imaging , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/injuries , Wounds, Nonpenetrating/diagnostic imaging , Accidents, Traffic , Adult , Humans , Male , Rupture/diagnostic imaging
5.
Echocardiography ; 24(10): 1099-104, 2007 Nov.
Article in English | MEDLINE | ID: mdl-18001367

ABSTRACT

A new tool has been recently introduced to the echocardiography armamentarium, live/real time three-dimensional (3D) transesophageal echocardiography (TEE). In these cases, we describe our initial experience in 13 patients studied intraoperatively and in the echocardiography suite. This important technology promises improved anatomic definition, diagnostic confidence, and novel views of the complicated cardiovascular pathology encountered in common clinical practice.


Subject(s)
Aortic Diseases/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Diseases/diagnostic imaging , Adult , Aged , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...