Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 5207-10, 2005.
Article in English | MEDLINE | ID: mdl-17281422

ABSTRACT

This paper presents a photoplethysmography sensor based on a heart rate monitor for a portable MP3 player. Two major design issues are addressed: one is to acquire the sensor signal with a proper amplitude despite a wide range of variation and the other is to handle the noise contaminated signal which is caused by a motion artifact. A benchmarking test with a professional medical photoplethysmography sensor shows that our device performs very well in calculating heart rate even though our photoplethysmography sensor module was designed to be cost effective.

2.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 5203-6, 2005.
Article in English | MEDLINE | ID: mdl-17281421

ABSTRACT

A measuring device for use in measuring calorie consumption includes a pulse input unit which detects a first heart rate of the user at a first point in an exercise period and a second heart rate of the user at a second point of the exercise period other than the first point, the pulse input unit not detecting a third heart rate between the first and second heart rates; and a controller which receives the detected first and second heart rates and calculates calories consumed using the detected first heart rate, the detected second heart rate, an at rest heart rate of the user, and one or more of an age, gender, weight, height and an at rest heart rate of the user. The measuring device is usable in a portable device, such as a portable digital audio and/or video reproducing apparatus.

3.
Conf Proc IEEE Eng Med Biol Soc ; 2004: 2364-7, 2004.
Article in English | MEDLINE | ID: mdl-17270745

ABSTRACT

We have developed nonintrusive type stress monitoring system based on the PDA (Personal Digital Assistance). This system separated sensing part of the physiological signal and estimating part of the stress states. First, sensing part consists of four electrodes such as one PPG electrode, two EDA electrodes and one SKT electrode. Sensing part was able to measuring heart rate, skin temperature variation, and electrodermal activity, all of which can be acquired without discomfort from finger. Second, estimating part was developed and verified for physiological signal database that was obtained from multiple subjects by presenting stress stimuli that were elaborated to effectively induce stress. This system is a useful measure of human stress in portabel device as PDA and smart phone.

SELECTION OF CITATIONS
SEARCH DETAIL
...