Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 85
Filter
1.
Eur Cell Mater ; 27: 50-62; discussion 62-3, 2014 Jan 25.
Article in English | MEDLINE | ID: mdl-24464728

ABSTRACT

Thermal damage to host bone is a possible source of compromise of fixation in patients undergoing cemented total hip replacement (THR). Data on the subject to date are derived from mathematical modelling powered by animal studies. The aim of this study was to assess the effect of cement thickness on osteocyte viability in a population of patients undergoing cemented THR. An in vivo model was designed and validated by means of a finite element analysis. During standard hip joint replacement in 14 patients, the femoral necks were exposed before final resection to the heat of a curing cement mantle equivalent to 2.5 (Group 1) or 5 mm (Group 2) in vivo in the cemented acetabulum. Matched controls were collected for each patient. Osteocyte counts and viability were assessed by means of haematoxylin and eosin (H&E) stain and lactate dehydrogenase (LDH) assay. Ex vivo experiments were performed to determine the extent of thermal insult. H&E staining proved unreliable for assessing thermal insult in the short term. The LDH assay was reliable and demonstrated a significant reduction in osteocyte viability to a depth of 2.19 mm in group 1 and 9.19 mm in group 2. There was a significant difference between the groups at all depths. The ex vivo experiments revealed thermoclines indicating that host bone in the population undergoing cemented THR is more sensitive to the thermal insult delivered by curing polymethylmethacrylate cement than previously believed. This thermal insult may weaken the fixation between bone and cement and contribute towards aseptic loosening, the commonest cause of failure of THRs.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hot Temperature/adverse effects , Osteocytes/pathology , Osteonecrosis/etiology , Polymethyl Methacrylate/adverse effects , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Case-Control Studies , Cell Survival , Female , Humans , Male
3.
J Bone Joint Surg Br ; 94(7): 889-94, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22733941

ABSTRACT

We prospectively followed 191 consecutive collarless polished tapered (CPT) femoral stems, implanted in 175 patients who had a mean age at operation of 64.5 years (21 to 85). At a mean follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were still alive. The fate of all original stems is known. The 16-year survivorship with re-operation for any reason was 80.7% (95% confidence interval 72 to 89.4). There was no loss to follow-up, with clinical data available on all 95 hips and radiological assessment performed on 90 hips (95%). At latest follow-up, the mean Harris hip score was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48). Stems subsided within the cement mantle, with a mean subsidence of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem (0.5%) has been revised due to aseptic loosening. In total seven stems were revised for any cause, of which four revisions were required for infection following revision of the acetabular component. A total of 21 patients (11%) required some sort of revision procedure; all except three of these resulted from failure of the acetabular component. Cemented acetabular components had a significantly lower revision burden (three hips, 2.7%) than Harris Galante uncemented components (17 hips, 21.8%) (p < 0.001). The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation. Its results are consistent with other polished tapered stem designs.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Cementation , Female , Follow-Up Studies , Hip Prosthesis/adverse effects , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Osteolysis/diagnostic imaging , Osteolysis/etiology , Prosthesis Design , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/etiology , Radiography , Reoperation , Treatment Outcome , Young Adult
4.
J Antimicrob Chemother ; 66(10): 2405-8, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21742678

ABSTRACT

OBJECTIVES: To determine outcomes for an antibiotic regimen using early switch to oral antibiotics for treatment of infected total hip replacement (THR) treated by either a one-stage or two-stage procedure. METHODS: Cases of infected THR were identified from the microbiology records on all orthopaedic infections in a 24 month period. Diagnosis was made by microbiological culture of theatre specimens and findings at the time of surgery. A standard approach of 10-14 days intravenous (iv) antibiotic followed by a switch to oral antibiotics either for 6-8 weeks until second-stage re-implantation or for up to 3 months following a one-stage procedure was used. The exact date of oral switch and antibiotic duration was determined by clinical resolution and C-reactive protein (CRP). Outcome was recorded as no microbiological or clinical evidence of relapse of infection or relapse after completing the antibiotic course. Follow-up duration for all cases at the time of study was 24-36 months after completion of antibiotic treatment. RESULTS: In 24 months, 19 patients underwent two-stage THR for infection, of which 17 were treated with oral antibiotics after a median of 14 days initial iv antibiotics. None relapsed. Four patients underwent one-stage THR and had 12-20 days iv then 6-26 weeks oral antibiotics with no relapse. CONCLUSIONS: Early oral antibiotic switch therapy was effective in patients treated at the Avon Orthopaedic Centre with infected THR and plays an important role in enabling patients to return to independence after revision surgery and avoid complications of prolonged iv access.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Arthroplasty, Replacement, Hip , Hip Prosthesis/microbiology , Prosthesis-Related Infections/drug therapy , Administration, Oral , Adult , Aged , Aged, 80 and over , Anti-Bacterial Agents/therapeutic use , Female , Humans , Infusions, Parenteral , Male , Middle Aged , Reoperation , Retrospective Studies , Treatment Outcome
5.
J Bone Joint Surg Br ; 93(8): 1045-8, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21768626

ABSTRACT

We reviewed the seven- to ten-year results of our previously reported prospective randomised controlled trial comparing total hip replacement and hemiarthroplasty for the treatment of displaced intracapsular fracture of the femoral neck. Of our original study group of 81 patients, 47 were still alive. After a mean follow up of nine years (7 to 10) overall mortality was 32.5% and 51.2% after total hip replacement and hemiarthroplasty, respectively (p = 0.09). At 100 months postoperatively a significantly greater proportion of hemiarthroplasty patients had died (p = 0.026). Three hips dislocated following total hip replacement and none after hemiarthroplasty. In both the total hip replacement and hemiarthroplasty groups a deterioration had occurred in walking distance (p = 0.02 and p < 0.001, respectively). One total hip replacement required revision compared with four hemiarthroplasties which were revised to total hip replacements. All surviving patients with a total hip replacement demonstrated wear of the cemented polyethylene component and all hemiarthroplasties had produced acetabular erosion. There was lower mortality (p = 0.013) and a trend towards superior function in patients with a total hip replacement in the medium term.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Femoral Neck Fractures/surgery , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/rehabilitation , Epidemiologic Methods , Female , Femoral Neck Fractures/rehabilitation , Hip Dislocation/etiology , Humans , Male , Middle Aged , Reoperation , Treatment Outcome , Walking
6.
J Bone Joint Surg Br ; 93(2): 158-63, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21282752

ABSTRACT

We compared the medium-term clinical and radiological results of hybrid total hip replacement (THR) with metal-on-metal Birmingham hip resurfacing (BHR) in two groups of 54 young patients matched for age, gender, body mass index and pre-operative levels of activity. The clinical outcome was assessed by the University of California, Los Angeles (UCLA) activity score, the Oxford Hip Score (OHS) and the EuroQol scores. Radiologically, all hips were assessed for migration and osteolysis, the hybrid THRs for polyethylene wear and the BHRs for a pedestal sign. The mean follow-up of the patients with a hybrid THR was ten years and for those with a BHR, nine years. Four patients with a hybrid THR and one with a BHR had died. In each group five were lost to follow-up. The revision rate of the hybrid THRs was 16.7% (9 of 54) and of the BHRs 9.3% (5 of 54) (p = 0.195). Radiographs of a further eight hybrid THRs demonstrated wear and osteolysis, and they await revision (p = 0.008). Of the unrevised BHRs 90% had radiological changes, of which approximately 50% had progressed over the previous four years. All hybrid THRs demonstrated linear polyethylene wear with a mean of 1.24 mm (0.06 to 3.03). The BHRs recorded superior OHS (p = 0.013), UCLA (p = 0.008), and EuroQol visual analogue scores (p = 0.009). After nine years, patients with BHRs remained more active and had a lower rate of revision than those with hybrid THRs. Both groups demonstrated progressive radiological changes at medium-term follow-up.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Joint/surgery , Osteoarthritis, Hip/surgery , Adolescent , Adult , Aged , Arthroplasty, Replacement, Hip/rehabilitation , Female , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/physiopathology , Hip Prosthesis , Humans , Male , Middle Aged , Motor Activity , Osteolysis/etiology , Osteolysis/surgery , Patient Satisfaction , Prosthesis Failure , Radiography , Recovery of Function , Reoperation , Treatment Outcome , Young Adult
7.
Ann R Coll Surg Engl ; 93(1): 54-6, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20836920

ABSTRACT

INTRODUCTION: Wound ooze is common following total knee arthroplasty (TKA) and persistent wound infection is a risk factor for infection, and increased length and cost of hospitalisation. PATIENTS AND METHODS: We undertook a prospective study to assess the effect of tourniquet time, peri-articular local anaesthesia and surgical approach on wound oozing after TKA. RESULTS: The medial parapatellar approach was used in 59 patients (77%) and subvastus in 18 patients (23%). Peri-articular local anaesthesia (0.25% Bupivacaine with 1:1,000,000 adrenalin) was used in 34 patients (44%). The mean tourniquet time was 83 min (range, 38-125 min). We found a significant association between cessation of oozing and peri-articular local anaesthesia (P = 0.003), length of the tourniquet time (P = 0.03) and the subvastus approach (P = 0.01). CONCLUSIONS: Peri-articular local anaesthesia, the subvastus approach and shorter tourniquet time were all associated with less wound oozing after total knee arthroplasty.


Subject(s)
Arthroplasty, Replacement, Knee , Postoperative Complications/prevention & control , Surgical Wound Infection/prevention & control , Wound Closure Techniques , Adult , Aged , Aged, 80 and over , Anesthesia, Local/methods , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Prospective Studies , Risk Factors , Surgical Wound Infection/etiology , Tourniquets , Treatment Outcome , Wound Healing
10.
J Bone Joint Surg Br ; 91(6): 725-9, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19483223

ABSTRACT

We undertook a randomised controlled trial to compare the outcomes of skin adhesive and staples for skin closure in total hip replacement. The primary outcome was the cosmetic appearance of the scar at three months using a surgeon-rated visual analogue scale. In all, 90 patients were randomised to skin closure using either skin adhesive (n = 45) or staples (n = 45). Data on demographics, surgical details, infection and oozing were collected during the in-patient stay. Further data on complications, patient satisfaction and evaluation of cosmesis were collected at three-month follow-up, and a photograph of the scar was taken. An orthopaedic and a plastic surgeon independently evaluated the cosmetic appearance of the scars from the photographs. No significant difference was found between groups in the cosmetic appearance of scars at three months (p = 0.172), the occurrence of complications (p = 0.3), or patient satisfaction (p = 0.42). Staples were quicker and easier to use than skin adhesive and also less expensive. Skin adhesive and surgical staples are both effective skin closure methods in total hip replacement.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Dermatologic Surgical Procedures , Surgical Stapling , Tissue Adhesives , Wound Healing/physiology , Adult , Aged , Aged, 80 and over , Cicatrix/prevention & control , Female , Humans , Male , Middle Aged , Patient Satisfaction , Surgical Stapling/adverse effects , Surgical Stapling/psychology , Tissue Adhesives/adverse effects , Treatment Outcome
11.
Int Orthop ; 33(4): 905-9, 2009 Aug.
Article in English | MEDLINE | ID: mdl-18437379

ABSTRACT

The aim of this postal survey was to determine the prevalence and impact of patient-perceived leg length discrepancy (LLD) at 5-8 years after primary total hip replacement (THR). A postal audit survey was undertaken of all consecutive patients who had a primary unilateral THR at one elective orthopaedic centre between April 1993 and April 1996. The questionnaire included the Oxford hip score (OHS) and questions about LLD. Questionnaires were received from 1,114 patients. In total, 329 THR patients (30%) reported an LLD, although radiographic analysis revealed that only 36% of these patients had anatomical LLD. Patients with a perceived LLD had a significantly poorer OHS (p < 0.001) and reported more limping than those patients without a perceived LLD. This study found that a third of patients perceived an LLD after THR and that perceived LLD was associated with a significantly poorer midterm functional outcome.


Subject(s)
Arthroplasty, Replacement, Hip , Leg Length Inequality/epidemiology , Leg Length Inequality/physiopathology , Leg/physiopathology , Self Concept , Aged , Female , Health Surveys , Humans , Leg Length Inequality/psychology , Male , Patient Satisfaction , Prevalence , Risk Factors , Treatment Outcome
12.
J Bone Joint Surg Br ; 90(11): 1422-7, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18978259

ABSTRACT

We have reviewed 70 Harris-Galante uncemented acetabular components implanted as hybrid hip replacements with cemented stems between 1991 and 1995 in 53 patients whose mean age was 40 years (19 to 49). The mean follow-up was for 13.6 years (12 to 16) with no loss to follow-up. We assessed the patients both clinically and radiologically. The mean Oxford hip score was 20 (12 to 46) and the mean Harris hip score 81 (37 to 100) at the final review. Radiologically, 27 hips (39%) had femoral osteolysis, 13 (19%) acetabular osteolysis, and 31 (44%) radiolucent lines around the acetabular component. Kaplan-Meier survival curves were constructed for the outcomes of revision of the acetabular component, revision of the component and polyethylene liner, and impending revision for progressive osteolysis. The cumulative survival for revision of the acetabular component was 94% (95% confidence interval 88.4 to 99.7), for the component and liner 84% (95% confidence interval 74.5 to 93.5) and for impending revision 55.3% (95% confidence interval 40.6 to 70) at 16 years. Uncemented acetabular components with polyethylene liners undergo silent lysis and merit regular long-term radiological review.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Femur/surgery , Hip Joint/surgery , Hip Prosthesis/standards , Acetabulum/surgery , Adult , Age Factors , Arthroplasty, Replacement, Hip/standards , Bone Cements , Coated Materials, Biocompatible/standards , Female , Follow-Up Studies , Humans , Male , Middle Aged , Patient Satisfaction , Polyethylenes , Prosthesis Design , Prosthesis Failure , Range of Motion, Articular , Treatment Outcome
13.
J Bone Joint Surg Br ; 90(1): 16-22, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18160493

ABSTRACT

We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip score. Radiological analysis was performed on calibrated plain radiographs taken in two planes. Complete radiological data on 110 patients (120 hips) and clinical follow-up on all the surviving 111 patients (122 hips) was available. The fate of all the hips was known. At final follow-up, the mean Harris Hip score was 86 (47 to 100), and 87 of 116 patients (75%) had good or excellent scores. Survival with revision of the stem for aseptic loosening as the endpoint was 100%; and survival with revision of the stem for any reason was 95.9% (95% confidence interval 87.8 to 96.8) at ten years. All the stems subsided vertically at the stem-cement interface in a predictable pattern, at an overall mean rate of 0.18 mm per year (0.02 to 2.16), but with a mean rate of 0.80 mm (0.02 to 2.5) during the first year. The mean total subsidence was 1.95 mm (0.21 to 24). Only three stems loosened at the cement-bone interface. There was excellent preservation of proximal femoral bone stock. There was a high incidence of Brooker III and IV heterotopic ossification affecting 25 patients (22%). The collarless polished tapered stem has an excellent clinical and radiological outcome at a minimum of ten years' follow-up. The pattern and magnitude of subsidence of the stem within the cement mantle occurred in a predictable pattern, consistent with the design philosophy.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Joint/surgery , Hip Prosthesis , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Cementation , Female , Follow-Up Studies , Hip Joint/diagnostic imaging , Humans , Male , Middle Aged , Prosthesis Design , Radiography , Retrospective Studies , Treatment Outcome
14.
J Bone Joint Surg Br ; 89(10): 1299-302, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17957067

ABSTRACT

We determined the ten-year life expectancy of 5831 patients who had undergone 6653 elective primary total hip replacements at a regional orthopaedic centre between April 1993 and October 2004. Using hospital, general practitioner and the local health authority records, we recorded the dates of death for those who died following surgery. The mean age at operation was 67 years (13 to 96) with a male:female ratio of 2:3. Of 1154 patients with a ten-year follow-up 340 (29.5%) had died a mean of 5.6 years (0 to 10) after surgery. Using Kaplan-Meier curves, the ten-year survival was 89% in patients under 65 years at surgery, 75% in patients aged between 65 and 74 years, and 51% in patients over 75. The standardised mortality rates were considerably higher for patients under 45 years, 20% higher for those between 45 and 64 years, and steadily reduced in patients aged 65 and over. The survival of cemented hip replacement derived from the Swedish Hip Arthroplasty Register Annual Report 2004 exceeds the life expectancy of patients over the age of 60 in our area, suggesting that cemented hip replacement is the procedure of choice in this population.


Subject(s)
Arthroplasty, Replacement, Hip/mortality , Life Expectancy , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/statistics & numerical data , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , United Kingdom
15.
J Orthop Surg (Hong Kong) ; 15(2): 167-9, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17709854

ABSTRACT

PURPOSE: To assess short- to medium-term outcome of the Omnifit constrained acetabular component in preventing dislocation in at-risk patients after total hip arthroplasty (THA). METHODS: 81 patients (mean age, 77 years) underwent either primary or revision THA with an Omnifit constrained acetabular component and were followed up clinically and radiologically for a mean period of 24 months. RESULTS: There was one dislocation and one revision for avulsion of the acetabulum. The remaining prostheses remained well fixed. CONCLUSIONS: In the short- to medium-term, the Omnifit constrained acetabular component is effective in preventing primary and recurrent dislocation in at-risk patients. Long-term follow-up is needed to assess whether good fixation is maintained. The Omnifit acetabular cup is recommended for elderly patients with limited life expectancy and functional demands.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Hip Dislocation/prevention & control , Hip Prosthesis , Aged , Aged, 80 and over , Female , Follow-Up Studies , Hip Dislocation/diagnostic imaging , Hip Dislocation/etiology , Humans , Male , Middle Aged , Osteoarthritis, Hip/surgery , Postoperative Complications , Prosthesis Design , Prosthesis Failure , Radiography , Reoperation , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
16.
J Bone Joint Surg Br ; 89(1): 21-5, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17259410

ABSTRACT

We determined the effect of the surgical approach on perfusion of the femoral head during hip resurfacing arthroplasty by measuring the concentration of cefuroxime in bone samples from the femoral head. A total of 20 operations were performed through either a transgluteal or an extended posterolateral approach. The concentration of cefuroxime in bone was significantly greater when using the transgluteal approach (mean 15.7 mg/kg; 95% confidence interval 12.3 to 19.1) compared with that using the posterolateral approach (mean 5.6 mg/kg; 95% confidence interval 3.5 to 7.8; p < 0.001). In one patient, who had the operation through a posterolateral approach, cefuroxime was undetectable. Using cefuroxime as an indirect measure of blood flow, the posterolateral approach was found to be associated with a significant reduction in the blood supply to the femoral head during resurfacing arthroplasty compared with the transgluteal approach.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Femur Head/blood supply , Osteoarthritis, Hip/surgery , Adolescent , Adult , Anti-Bacterial Agents/pharmacokinetics , Cefuroxime/pharmacokinetics , Female , Femur Head/metabolism , Humans , Male , Middle Aged , Prospective Studies , Regional Blood Flow
17.
Hip Int ; 17(2): 88-90, 2007.
Article in English | MEDLINE | ID: mdl-19197851

ABSTRACT

BACKGROUND: Lungs exposed to particulate debris may be damaged by proteolytic enzymes during phagocytosis. Damage is worse if patients are deficient in alpha1-antitrypsin (A1AT), which helps neutralise these enzymes. We investigated the possibility that A1AT deficiency contributes to aseptic loosening following total hip replacement (THR) when wear particles are phagocytosed. METHOD: A1AT level and phenotype were measured in patients attending for revision THR within 15 years of implantation. Periprosthetic lysis was graded from radiographs by three hip surgeons with an interest in revision, blinded to history and A1AT results. Patients were grouped according to presence of high or low levels of lysis radiologically. Mean A1AT levels were calculated for the two groups. RESULTS: 17 patients were recruited, mean age 69.5, mean interval between surgery and onset of pain 8.3 years (2-12). Two were heterozygotes for the less active S form of A1AT and therefore mildly deficient. Time to onset of pain in both was 12 years. Radiographs were available for 12 patients. Combining the results for all reviewers the probability of a difference in the level of A1AT between the high and low lysis groups reached statistical significance (p=0.008). For all reviewers, the mean A1AT level in their high lysis group was raised and greater than that of their low lysis group. Both A1AT-deficient patients were classified as high lysis by all reviewers. CONCLUSIONS: The incidence of A1AT deficiency is only marginally higher in this group than in the general population therefore A1AT deficiency is unlikely to be a common cause of failure of hip replacements. Elevated levels of A1AT in the presence of lysis suggest that A1AT may play a role in the aetiology of aseptic loosening. A1AT-deficient patients may be at increased risk of osteolysis. Further work is needed to evaluate this and to assess vulnerability of A1AT-deficient patients to lysis.

18.
J Bone Joint Surg Br ; 88(12): 1584-90, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17159168

ABSTRACT

We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to follow-up. The rate of revision of the femoral component for aseptic loosening and osteolysis was 1.1% (1 stem), that for revision for any cause was 2.2% (2 stems), and for re-operation for any cause was 21.6% (19 hips). Re-operation was because of failure of the acetabular component in all but two hips. All but one femoral component subsided within the cement mantle to a mean of 1.52 mm (0 to 8.3) at the final follow-up. One further stem had subsided excessively (8 mm) and had lucent lines at the cement-stem and cement-bone interfaces. This was classified as a radiological failure and is awaiting revision. One stem was revised for deep infection and one for excessive peri-articular osteolysis. Defects of the cement mantle (Barrack grade C and D) were found in 28% of stems (25 hips), associated with increased subsidence (p = 0.01), but were not associated with endosteal lysis or failure. Peri-articular osteolysis was significantly related to the degree of polyethylene wear (p < 0.001), which was in turn associated with a younger age (p = 0.01) and male gender (p < 0.001). The use of the Exeter metal-backed acetabular component was a notable failure with 12 of 32 hips (37.5%) revised for loosening. The Harris-Galante components failed with excessive wear, osteolysis and dislocation with 15% revised (5 of 33 hips). Only one of 23 hips with a cemented Elite component (4%) was revised for loosening and osteolysis. Our findings show that the Exeter Universal stem implanted outside the originating centre has excellent medium-term results.


Subject(s)
Hip Prosthesis , Adolescent , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Cementation , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteolysis/etiology , Prosthesis Design , Prosthesis Failure , Reoperation , Treatment Outcome
19.
J Bone Joint Surg Am ; 88(12): 2583-9, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17142407

ABSTRACT

BACKGROUND: Hemiarthroplasty and total hip arthroplasty are commonly used to treat displaced intracapsular fractures of the femoral neck, but each has disadvantages and the optimal treatment of these fractures remains controversial. METHODS: In the present prospectively randomized study, eighty-one patients who had been mobile and lived independently before they had sustained a displaced fracture of the femoral neck were randomized to receive either a total hip arthroplasty or a hemiarthroplasty. The mean age of the patients was seventy-five years. Outcome was assessed with use of the Oxford hip score, and final radiographs were assessed. RESULTS: After a mean duration of follow-up of three years, the mean walking distance was 1.17 mi (1.9 km) for the hemiarthroplasty group and 2.23 mi (3.6 km) for the total hip arthroplasty group, and the mean Oxford hip score was 22.3 for the hemiarthroplasty group and 18.8 for the total hip arthroplasty group. Patients in the total hip arthroplasty group walked farther (p=0.039) and had a lower (better) Oxford hip score (p=0.033) than those in the hemiarthroplasty group. Twenty of thirty-two living patients in the hemiarthroplasty group had radiographic evidence of acetabular erosion at the time of the final follow-up. None of the hips in the hemiarthroplasty group dislocated, whereas three hips in the total hip arthroplasty group dislocated. In the hemiarthroplasty group, two hips were revised to total hip arthroplasty and three additional hips had acetabular erosion severe enough to indicate revision. In the total hip arthroplasty group, one hip was revised because of subsidence of the femoral component. CONCLUSIONS: Total hip arthroplasty conferred superior short-term clinical results and fewer complications when compared with hemiarthroplasty in this prospectively randomized study of mobile, independent patients who had sustained a displaced fracture of the femoral neck.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures/surgery , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Female , Health Status Indicators , Humans , Male , Middle Aged , Prospective Studies , Reoperation , Treatment Outcome
20.
Injury ; 37(8): 712-7, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16765960

ABSTRACT

OBJECTIVES: The aim was to monitor the inhospital progress of 170 patients sustaining proximal femoral fractures. The extent of delay in discharge was recorded and what effect this prolonged hospitalisation had on nosocomial infection rates. SETTING: A regional trauma centre. DESIGN: A prospective observational study. PATIENTS AND PARTICIPANTS: All consecutive patients sustaining proximal femoral fracture over 60 years of age. INTERVENTION: The same clinician monitored each patient throughout their inhospital stay. Factors recorded included nosocomial infection acquired and when, mobility scores, loss of independence, delay in discharge amongst others. MAIN OUTCOME: Delay in discharge, incidence of nosocomial infection and mobility scores. RESULTS: Nosocomial infection occurred in 58% of patients (99 patients) when discharge was delayed beyond 8 days (after surgery). Eighty-five per cent of patients (145 patients) achieved their maximum mobility score by the 8th, and 95% (162 patients) by the 10th postoperative day. CONCLUSIONS: Patients with proximal femoral fracture derive no benefit from acute hospital admission of more than 8 days and the majority acquire nosocomial infection after this.


Subject(s)
Hip Fractures/physiopathology , Hip Fractures/therapy , Locomotion/physiology , Recovery of Function/physiology , Aged , Aged, 80 and over , Cross Infection/epidemiology , Female , Follow-Up Studies , Hip Fractures/mortality , Humans , Length of Stay , Male , Middle Aged , Patient Discharge , Prospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...