Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMJ ; 384: e078581, 2024 03 05.
Article in English | MEDLINE | ID: mdl-38443074

ABSTRACT

OBJECTIVE: To evaluate the diagnostic accuracy and safety of using magnetically guided capsule endoscopy with a detachable string (ds-MCE) for detecting and grading oesophagogastric varices in adults with cirrhosis. DESIGN: Prospective multicentre diagnostic accuracy study. SETTING: 14 medical centres in China. PARTICIPANTS: 607 adults (>18 years) with cirrhosis recruited between 7 January 2021 and 25 August 2022. Participants underwent ds-MCE (index test), followed by oesophagogastroduodenoscopy (OGD, reference test) within 48 hours. The participants were divided into development and validation cohorts in a ratio of 2:1. MAIN OUTCOME MEASURES: The primary outcomes were the sensitivity and specificity of ds-MCE in detecting oesophagogastric varices compared with OGD. Secondary outcomes included the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices and the diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices. RESULTS: ds-MCE and OGD examinations were completed in 582 (95.9%) of the 607 participants. Using OGD as the reference standard, ds-MCE had a sensitivity of 97.5% (95% confidence interval 95.5% to 98.7%) and specificity of 97.8% (94.4% to 99.1%) for detecting oesophagogastric varices (both P<0.001 compared with a prespecified 85% threshold). When using the optimal 18% threshold for luminal circumference of the oesophagus derived from the development cohort (n=393), the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices in the validation cohort (n=189) were 95.8% (89.7% to 98.4%) and 94.7% (88.2% to 97.7%), respectively. The diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices was 96.3% (92.6% to 98.2%), 96.9% (95.2% to 98.0%), and 96.7% (95.0% to 97.9%), respectively. Two serious adverse events occurred with OGD but none with ds-MCE. CONCLUSION: The findings of this study suggest that ds-MCE is a highly accurate and safe diagnostic tool for detecting and grading oesophagogastric varices and is a promising alternative to OGD for screening and surveillance of oesophagogastric varices in patients with cirrhosis. TRIAL REGISTRATION: ClinicalTrials.gov NCT03748563.


Subject(s)
Capsule Endoscopy , Esophageal and Gastric Varices , Varicose Veins , Adult , Humans , Esophageal and Gastric Varices/diagnosis , Esophageal and Gastric Varices/etiology , Liver Cirrhosis/complications , Prospective Studies
2.
Sci Rep ; 9(1): 14909, 2019 10 17.
Article in English | MEDLINE | ID: mdl-31624309

ABSTRACT

Operative Link on Gastritis Assessment (OLGA) and Operative Link on Gastric Intestinal Metaplasia Assessment (OLGIM) were adopted to evaluate gastric risk stratification in five biopsy samples. This study aimed to evaluate the degree of gastric atrophy (GA) and intestinal metaplasia (IM) in five locations to detect a more representative biopsy sample in gastric cancer (GC) screening. Our study enrolled 368 patients and 5 biopsy pieces were acquired from them. Gastric risk stratification was calculated by OLGA and OLGIM staging system. The results revealed that the IM score in the incisura angularis was higher than that in the larger and lesser curvature of corpus mucosa (p = 0.037 and p = 0.030, respectively) and the IM score in the lesser curvature of antrum mucosa was higher than that in the incisura angularis mucosa (p = 0.018). IM is more frequently observed in the angulus region than in the lesser curvature of corpus in the mild degree (p = 0.004) and mild IM lesions in the lesser curvature of antrum were more frequently observed than in the incisura angularis mucosa (p = 0.004), Four biopsy pieces protocol (larger curvature and lesser curvature of the antrum, lesser curvature of the corpus and angulus) demonstrated accurate consistency (97.83% and 98.37%, respectively) with a Kendall's tau-b of higher than 0.990, along with low misdiagnosis rates of OLGA and OLGIM (III + IV) (9.76% and 5.00%, respectively). Three biopsy pieces protocol (lesser curvature of the antrum and corpus, angulus biopsy) in OLGA and OLGIM staging system was close to the standard protocol (five biopsy specimens) with a consistency of 94.84% and 94.29% and has a Kendall's tau-b higher than 0.950 and diagnostic omission rates of 9.76% and 5.00%, respectively, which was exactly the same with the four biopsy pieces protocol. Furthermore, it had the second-highest Youden index (0.902 and 0.950, respectively) and area under the ROC curve (0.992 and 0.996, respectively) for the screening of high-risk GC by OLGA and OLGIM stages. Thus, we recommended the angulus and the lesser curvature of antrum as a conventional biopsy and three biopsy pieces for further GC risk screening.


Subject(s)
Early Detection of Cancer/methods , Gastric Mucosa/pathology , Mass Screening/methods , Precancerous Conditions/diagnosis , Stomach Neoplasms/diagnosis , Adult , Aged , Aged, 80 and over , Biopsy/methods , Biopsy/standards , Clinical Protocols , Early Detection of Cancer/standards , Female , Gastric Mucosa/diagnostic imaging , Gastritis, Atrophic/diagnosis , Gastritis, Atrophic/pathology , Gastroscopy/methods , Gastroscopy/standards , Humans , Male , Mass Screening/standards , Metaplasia/diagnosis , Metaplasia/pathology , Middle Aged , Practice Guidelines as Topic , Precancerous Conditions/pathology , Prospective Studies , ROC Curve , Risk Factors , Stomach Neoplasms/pathology , Stomach Neoplasms/prevention & control , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...