2.
J Med Case Rep ; 18(1): 216, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38693545

ABSTRACT

BACKGROUND: Orbital metastasis is a possible complication of small cell lung cancer and a pattern of bilateral invasion of the extraocular muscles has rarely been reported in literature. CASE PRESENTATION: A 46-year-old white male with a past medical history of smoking and stage IV small cell lung carcinoma presented with loss of vision and pain in the left eye. Examination revealed bilateral proptosis and left afferent pupillary defect, and visual acuity was hand motion on the left eye and 4/10 on the right eye. An orbital computed tomography scan showed a compression of the left optic nerve between the extraocular muscles at the apex, and a lateral canthotomy was performed for a new-onset compressive optic neuropathy, with residual visual improvement. There was also significant enlargement of the extraocular muscles in the right orbit. The patient was maintained in palliative treatment with both chemotherapy and local medical and surgical (amniotic membrane cover for exposure keratopathy) ophthalmological treatments until he eventually died 5 months after. CONCLUSION: Bilateral metastasis to the extraocular muscles is a very rare manifestation of small cell lung cancer and the palliative treatment in these cases is challenging.


Subject(s)
Lung Neoplasms , Oculomotor Muscles , Small Cell Lung Carcinoma , Humans , Male , Middle Aged , Fatal Outcome , Lung Neoplasms/pathology , Oculomotor Muscles/pathology , Oculomotor Muscles/diagnostic imaging , Orbital Neoplasms/secondary , Orbital Neoplasms/surgery , Orbital Neoplasms/diagnostic imaging , Palliative Care , Small Cell Lung Carcinoma/pathology , Tomography, X-Ray Computed
3.
Case Rep Ophthalmol ; 15(1): 250-255, 2024.
Article in English | MEDLINE | ID: mdl-38524876

ABSTRACT

Introduction: Conjunctival cysts of the orbit development are a rare complication in enucleated patients. They result from the entrapment of conjunctival epithelium within the orbit. Case Presentation: We report the case of a 25-year-old man with a history of enucleation for a retinoblastoma of the right eye who presented with difficulty in fitting his eye prothesis. On his past medical records, there was no reference to the placement of any orbital implant at the time of the surgery. Biomicroscopy of the right eye revealed a thickened bulbar conjunctiva, an inferior symblepharon, and a translucid central area with vascularization. Imaging was remarkable for a cystic cavity filling the whole right orbit. Biopsy revealed the diagnosis of a conjunctival cyst, and drainage was performed, alleviating the patient's symptoms. Conclusion: Orbital conjunctival cysts may pose a clinical problem, and treatment modalities include surgical excision, absolute alcohol injection, and trichloroacetic acid injection.

4.
J Cataract Refract Surg ; 50(4): 345-351, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37962186

ABSTRACT

PURPOSE: To study the effect of ocular biomechanics on the prediction error of intraocular lens (IOL) power calculation. SETTING: Centro Hospitalar Universitário do Porto, Porto, Portugal. DESIGN: Prospective longitudinal study. METHODS: This study included 67 subjects. Before cataract surgery subjects underwent biometry with IOLMaster 700 and biomechanical analysis with Corvis Scheimpflug technology. The targeted spherical equivalent was calculated with SRK-T and Barrett Universal II. Associations between prediction error (PE), absolute prediction error (AE), and biometric and biomechanical parameters were performed with stepwise multivariate linear correlation analysis. RESULTS: Using the SRKT formula, there was association between PE and Corvis Biomechanical Index (CBI, B = -0.531, P = .011) and between AE and the horizontal offset between the center of the pupil and the visual axis (angle κ, B = -0.274, P = .007). Considering the Barret Universal II formula, PE was independently associated with anterior chamber depth ( B = -0.279, P = .021) and CBI ( B = -0.520, P = .013) and AE was associated with angle κ ( B = -0.370, P = .007). CONCLUSIONS: A large angle κ may reduce the predictability of IOL power calculation. Ocular biomechanics likely influence the refractive outcomes after IOL implantation. This study showed that eyes with softer corneal biomechanics had more myopic PE. This may relate to anteriorization of the effective lens position. Dynamic measurements may be the way to progress into future formulas.


Subject(s)
Lenses, Intraocular , Phacoemulsification , Humans , Lens Implantation, Intraocular , Visual Acuity , Prospective Studies , Biomechanical Phenomena , Longitudinal Studies , Refraction, Ocular , Biometry , Retrospective Studies , Optics and Photonics
5.
Cureus ; 15(7): e41386, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37546127

ABSTRACT

PURPOSE: To compare different light-based devices, namely, intense pulsed light (IPL) and IPL with low-level light therapy (LLLT), in the treatment of meibomian gland dysfunction (MGD). METHODS: This was a prospective, observational study that included patients with MGD. Group 1 included 58 eyes treated with IPL (eye-light®, Espansione Marketing S.p.A., Bologna, Italy), followed by LLLT (my-mask®, Espansione Marketing S.p.A., Bologna, Italy); Group 2 included 60 eyes treated with IPL (E>Eye®, E-Swin, Houdan, France); and Group 3 included 58 eyes treated with IPL (Thermaeye Plus®, OptiMed, Sydney, Australia). The presence of symptoms (Ocular Surface Disease Index (OSDI)) and ocular surface changes were evaluated at baseline, three weeks, and six months after treatment. RESULTS: At week three, there was an improvement in the OSDI in all groups (p<0.001), without differences among them (p=0.339). The lipid layer thickness (LLT) increased in Groups 1 and 2 (p<0.001), with a similar variation (p=0.144). Patients with superior OSDI and lower LLT at baseline had the greatest improvement in the respective parameters (p<0.001). The basal tear flow increased in Group 1 (p=0.012). Corneal staining (CS) significantly decreased in Groups 2 (p<0.001) and 3 (p<0.001). At six months, compared to three weeks, there was further improvement in the OSDI (p<0.001) and the LLT (p=0.007), in Group 1, and an increase in the presence of CS in Group 3 (p=0.011). CONCLUSION: IPL treatment led to a sustained decrease in patients' symptoms, even after six months. Different IPL devices seem to have different beneficial effects. Adding LLLT to IPL appears to have an additional long-term beneficial effect as well as positive effects on the lacrimal gland.

6.
Am J Ophthalmol ; 251: 126-142, 2023 07.
Article in English | MEDLINE | ID: mdl-36549584

ABSTRACT

PURPOSE: To optimize artificial intelligence (AI) algorithms to integrate Scheimpflug-based corneal tomography and biomechanics to enhance ectasia detection. DESIGN: Multicenter cross-sectional case-control retrospective study. METHODS: A total of 3886 unoperated eyes from 3412 patients had Pentacam and Corvis ST (Oculus Optikgeräte GmbH) examinations. The database included 1 eye randomly selected from 1680 normal patients (N) and from 1181 "bilateral" keratoconus (KC) patients, along with 551 normal topography eyes from patients with very asymmetric ectasia (VAE-NT), and their 474 unoperated ectatic (VAE-E) eyes. The current TBIv1 (tomographic-biomechanical index) was tested, and an optimized AI algorithm was developed for augmenting accuracy. RESULTS: The area under the receiver operating characteristic curve (AUC) of the TBIv1 for discriminating clinical ectasia (KC and VAE-E) was 0.999 (98.5% sensitivity; 98.6% specificity [cutoff: 0.5]), and for VAE-NT, 0.899 (76% sensitivity; 89.1% specificity [cutoff: 0.29]). A novel random forest algorithm (TBIv2), developed with 18 features in 156 trees using 10-fold cross-validation, had a significantly higher AUC (0.945; DeLong, P < .0001) for detecting VAE-NT (84.4% sensitivity and 90.1% specificity; cutoff: 0.43; DeLong, P < .0001) and a similar AUC for clinical ectasia (0.999; DeLong, P = .818; 98.7% sensitivity; 99.2% specificity [cutoff: 0.8]). Considering all cases, the TBIv2 had a higher AUC (0.985) than TBIv1 (0.974; DeLong, P < .0001). CONCLUSIONS: AI optimization to integrate Scheimpflug-based corneal tomography and biomechanical assessments augments accuracy for ectasia detection, characterizing ectasia susceptibility in the diverse VAE-NT group. Some patients with VAE may have true unilateral ectasia. Machine learning considering additional data, including epithelial thickness or other parameters from multimodal refractive imaging, will continuously enhance accuracy. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.


Subject(s)
Keratoconus , Humans , Retrospective Studies , Corneal Topography/methods , Keratoconus/diagnosis , Artificial Intelligence , Dilatation, Pathologic/diagnosis , Corneal Pachymetry/methods , Cross-Sectional Studies , Cornea/diagnostic imaging , ROC Curve , Tomography/methods
7.
Clin Ophthalmol ; 16: 4003-4010, 2022.
Article in English | MEDLINE | ID: mdl-36510598

ABSTRACT

Purpose: To study the clinical benefit of low-level light therapy when associated with intense pulsed light for the treatment of meibomian gland dysfunction. Methods: An observational study. Two groups of patients that were treated with IPL were considered: group 1 (31 subjects, 62 eyes), intense pulsed light followed by low-level light therapy and group 2 (31 subjects, 62 eyes) intense pulsed light alone. In both groups, treatments were performed in 3 sessions and subjects were evaluated at baseline and 3 weeks after the last treatment session. Values are shown as mean difference ± standard deviation. Results: We observed a significant improvement in OSDI-12 score and lipid layer thickness, in both groups (-22.7±17.5, p<0.001 in group 1 and -23.6±23.8, p<0.001 in group 2 for OSDI and +18.6 ± 37.0, p<0.001 in group 1 and +19.9 ± 26.4, p<0.001 in group 2 for lipid layer thickness). Despite no differences between groups at baseline (p=0.469), only group 1 had a significant improvement in Schirmer test (+1.6±4.8, p=0.009 in group 1 and +1.7±6.9, p=0.057 in group 2). No significant side effects were noted. No patient in any group felt subjectively "worse" after the treatment. Conclusion: Intense pulsed light seems effective and safe for the treatment of meibomian gland dysfunction, improving symptoms and the tear film lipid layer. This study shows no strong evidence of the benefit of low-level light therapy, but it shows weak evidence that it may further improve aqueous tear production.

8.
J Cataract Refract Surg ; 48(9): 1004-1009, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35239580

ABSTRACT

PURPOSE: To evaluate the indications for pIOL explantation, pIOL survival time, and visual outcomes and access endothelial cell loss (ECL) after explantation. SETTING: Ophthalmology Department, Centro Hospitalar Universitário do Porto, Portugal. DESIGN: Retrospective longitudinal study. METHODS: A chart review was performed for all consecutive patients who underwent pIOL explantation from January 2010 to December 2019 in a single center. RESULTS: This study included 175 eyes of 112 patients (77% women). The mean pIOL survival was 12.9 ± 4.8 (3.7 to 28.6) years, and the mean follow-up period after explantation was 4.1 ± 3.0 (0.3 to 9.9) years. The most frequent causes for explantation were cataract formation (44.0%, n = 77) and ECL (50.3%, n = 88). During the follow-up period after explantation, the mean ECL rate was 2.27 ± 9.32%/year in the cataract group and -2.14 ± 10.24%/year in the ECL group, reflecting a positive change in cell density in the latter. 8 eyes (4.6%) required a corneal transplant during the follow-up. The mean corrected distance visual acuity was 0.17 ± 0.24 logMAR at the last visit. CONCLUSIONS: This study demonstrated that pIOL explantation, after a mean survival time of 13 years, was a safe procedure. The main causes for explantation were cataract formation and ECL. Most patients showed a sustained improvement in visual acuity and endothelial cell density after pIOL explantation, and yet its timing should be ideal to avoid irreversible complications.


Subject(s)
Cataract , Phakic Intraocular Lenses , Female , Follow-Up Studies , Humans , Lens Implantation, Intraocular , Longitudinal Studies , Male , Postoperative Complications , Refraction, Ocular , Retrospective Studies
9.
Ophthalmic Res ; 65(4): 361-376, 2022.
Article in English | MEDLINE | ID: mdl-35226900

ABSTRACT

INTRODUCTION: Accommodative esotropia (AET) is characterized by an esodeviation of the eyes due to uncorrected hyperopia, deficient fusional divergence, or high accommodative convergence. Decreasing hyperopia would reduce accommodative convergence and strabismus. We sought to review the existing evidence regarding the outcomes of refractive surgery in patients with AET. METHODS: A four-database search (Pubmed, ISI Web of Science, Cochrane, and Scopus) was performed from inception to March 2021 using the following MeSH terms: ("Refractive Surgical Procedures" OR "Keratomileusis, Laser In Situ" OR "Photorefractive Keratectomy" OR "Lens Implantation, Intraocular") AND ("Esotropia" OR "Accommodative Esotropia" OR "Refractive Esotropia" OR "Accommodative Strabismus"). No meta-analysis was performed due to studies' heterogeneity. RESULTS: Twenty-eight studies including 22 case series enrolling 378 patients and 6 case reports enrolling 8 patients were selected among 185 original abstracts. In the case series, a total of 378 patients (726 eyes) were recruited with an age range of 8-52 years. All studies reported mean follow-up periods of at least 12 months. Photorefractive keratectomy was performed in 7 studies, laser-assisted in situ keratomileusis in 9 studies, laser-assisted sub-epithelial keratectomy was reported in 1 study, and 3 studies implanted intraocular lenses, including iris-fixated and collamer. Considering the adult patients with a preoperative corrected esodeviation ≤10 prism diopters (PD) (n = 129), all but 5 (3.9%) presented orthophoria or ≤10PD after refractive surgery. All children but 4 (4.5%) ended up with an esodeviation ≤10PD after surgery with those exceptions being in the range of 11-15PD. Six case reports were included in this review, comprising a total of 8 patients (16 eyes) with an age range of 7-34 years and a follow-up range of 4-48 months. Six case reports were included in this review, comprising a total of 8 patients (16 eyes) with an age range of 7-34 years and a follow-up range of 4-48 months. CONCLUSION: Evidence produced so far points out that refractive surgery may be an alternative for spectacle correction for adults with AET ≤10PD. There is not enough evidence to recommend its use for patients under 18 years of age. The safety and predictability of these procedures for this purpose remains unclear as the selection criteria used for these patients are much different than the usual indications and there are no studies with long-term follow-up.


Subject(s)
Esotropia , Hyperopia , Keratomileusis, Laser In Situ , Strabismus , Adolescent , Adult , Child , Child, Preschool , Humans , Infant , Middle Aged , Young Adult , Esotropia/surgery , Keratomileusis, Laser In Situ/methods , Refraction, Ocular , Strabismus/surgery , Visual Acuity
10.
Int J Retina Vitreous ; 8(1): 6, 2022 Jan 08.
Article in English | MEDLINE | ID: mdl-34998439

ABSTRACT

BACKGROUND: The variable visual function observed in diabetic retinopathy (DR) patients is not fully explained by the classic staging system. Our purpose was to evaluate choroidal changes, in standardized sectors, in DR patients and to find associations between choroidal measurements and visual function. METHODS: Cross-sectional study that included the right eye of diabetic patients (n = 265) without active edema, ischemia or neovascularization and age-matched controls (n = 73). Optical coherence tomography (OCT) imaging was performed with enhanced depth imaging protocol. Choroidal vascularity index (CVI) was calculated in a 5 mm scan centered in the fovea. RESULTS: CVI decreased with age (p < 0.001) but was not influenced by axial length. A multivariate analysis adjusting for age confirmed a significant difference in CVI between DR eyes that had previous treatments (intravitreal injections and/or photocoagulation) compared to control eyes (p = 0.013) and to DR eyes that never required treatment (p = 0.002). There was no significant difference between non-DR diabetic patients and normal controls. Considering the group of DR patients that had previous treatments, in eyes without optic media opacification, BCVA correlated with CVI (r = - 0.362, p < 0.001), whereas full retina thickness and individual retinal layer thickness did not (p > 0.066). CONCLUSIONS: A reduction in CVI was observed in patients with a more advanced stage of DR. In treated DR patients with stable disease, choroidal biomarkers correlated with best-corrected visual acuity whereas retinal biomarkers did not. TRIAL REGISTRATION: N/A.

11.
Clin Ophthalmol ; 16: 71-83, 2022.
Article in English | MEDLINE | ID: mdl-35035215

ABSTRACT

BACKGROUND: To evaluate biomechanical parameters of the cornea provided by Corvis ST in patients with ocular hypertension, primary open-angle glaucoma, and amyloidotic glaucoma and to compare with healthy controls. METHODS: This was a cross-sectional study of patients with ocular hypertension, primary open-angle glaucoma, and amyloidotic glaucoma that underwent Corvis ST imaging. Primary outcome was the comparison of corneal biomechanical parameters between study groups after adjusting for age, gender, Goldmann intraocular pressure (GAT-IOP), and prostaglandin analogues medication. Secondary outcome was the comparison of different IOP measurements in each group. RESULTS: One hundred and eighty-three eyes from 115 patients were included: 61 with primary open-angle glaucoma, 32 with amyloidotic glaucoma, 37 with ocular hypertension and 53 were healthy controls. Amyloidotic glaucoma group had smaller radius (p=0.025), lower deflection amplitude at highest concavity (p=0.019), and higher integrated radius (p=0.014) than controls. Ocular hypertension group had higher stiffness parameter at first applanation (p=0.043) than those with primary open-angle glaucoma, and higher stress-strain index (p=0.049) than those with amyloidotic glaucoma. Biomechanically corrected intraocular pressure was significantly lower than Goldmann intraocular pressure in group with primary open-angle glaucoma (p=0.005) and control group (p=0.013), and Goldmann intraocular pressure adjusted for pachymetry in group with primary open-angle glaucoma (p=0.01). CONCLUSION: Eyes with amyloidotic glaucoma have more deformable corneas, while eyes with ocular hypertension have less deformable corneas. These findings may be linked to the susceptibility to glaucomatous damage and progression. There were significant differences between Goldmann applanation tonometry and biomechanically corrected intraocular ocular pressure provided by Corvis ST.

12.
Ophthalmic Res ; 64(6): 960-966, 2021.
Article in English | MEDLINE | ID: mdl-34348332

ABSTRACT

INTRODUCTION: The hindrance of a macular laser treatment for diabetic macular edema (DME) remains unclear. Our purpose was to evaluate macular functional and structural changes after focal macular photocoagulation for DME. METHODS: This is a prospective cohort study that included patients with mild diabetic retinopathy, submitted to focal macular laser treatment as monotherapy for DME. Patients underwent optical coherence tomography and microperimetry after the necessary number of treatment sessions for complete resolution of DME. Eyes were compared in each macular sector (superior, temporal, and inferior 1- to 3-mm parafoveal ring) according to the presence of laser spots. Relative sensitivity was calculated as sectorial sensitivity divided by general sensitivity. RESULTS: Sixty-four eyes were included. In sectors submitted to focal photocoagulation, we observed a significant reduction in absolute sensitivity (-1.0 to -0.4 dB, depending on the sector analyzed) and relative sensitivity (-2.1 to -0.6%) together with a reduction in the outer nuclear layer (ONL) thickness (-8 to -3 µm). The number of laser spots correlated with both functional and structural changes. CONCLUSION: In macular sectors that underwent photocoagulation, we found a small reduction in retinal sensitivity together with a reduction in the corresponding ONL thickness.


Subject(s)
Diabetes Mellitus , Diabetic Retinopathy , Macular Edema , Diabetic Retinopathy/surgery , Humans , Light Coagulation , Macular Edema/etiology , Macular Edema/surgery , Prospective Studies , Visual Acuity
13.
Clin Ophthalmol ; 15: 2803-2811, 2021.
Article in English | MEDLINE | ID: mdl-34234402

ABSTRACT

PURPOSE: To analyse the clinical outcome in patients with meibomian gland dysfunction (MGD) who underwent intense pulsed light (IPL) plus low-level light therapy (LLL). MATERIALS AND METHODS: The prospective non-comparative study included identified by MGD patients with altered interferometry and lower loss area of the meibomian glands (LAMG), who underwent IPL plus LLL, between July 2020 and August 2020. A multimodal assessment was performed before, 2-3 weeks, and 6 months after treatment. The main outcome was lipid layer thickness (LLT) and the secondary outcomes were the ocular surface disease index (OSDI) score, presence of corneal fluorescein staining (CFS), blink rate (BR), Schirmer test (ST), tear meniscus height (TMH), tear osmolarity (OSM), non-invasive break-up time (NIBUT) and LAMG. RESULTS: This study included 62 eyes of 31 patients, 61.3% female, with a mean age of 66.94±9.08 years at the time of IPL plus LLL treatment. LLT (<0.001) grades improved 6 months after treatment. The mean OSDI score improved (p<0.001) from 45.02±21.17 (severe symptoms) to 22.35±17.68 (moderate symptoms) at 2-3 weeks and 8.24±17.9.91 (normal) at 6 months after treatment. CFS was identified in 51.6% (32/62) before and in 45.2% (28/62) 6 months (p=0.293) after treatment. ST (p=0.014) grades improved; OSM grades mild worsened (p<0.001); TMH, NIBUT and LAMG grades did not modify 6 months after treatment. No patient suffered any adverse effects. CONCLUSION: IPL combined with LLL was effective and safe, improving the lipid layer thickness in MGD and decreasing the level of symptoms.

14.
Clin Ophthalmol ; 15: 1409-1423, 2021.
Article in English | MEDLINE | ID: mdl-33854295

ABSTRACT

BACKGROUND: In recent years, increasing interest has arisen in the application of data from corneal biomechanics in many areas of ophthalmology, particularly to assist in the detection of early corneal ectasia or ectasia susceptibility, to predict corneal response to surgical or therapeutic interventions and in glaucoma management. Technology has evolved and, recently, the Scheimpflug principle was associated with a non-contact air-puff tonometer, allowing a thorough analysis of corneal biomechanics and a biomechanically corrected intraocular pressure assessment, opening up new perspectives both in ophthalmology and in other medical areas. Data from corneal biomechanics assessment are being integrated in artificial intelligence models in order to increase its value in clinical practice. OBJECTIVE: To review the state of the art in the field of corneal biomechanics assessment with special emphasis to the technology based on ultra-high-speed Scheimpflug imaging during non-contact tonometry. SUMMARY: A meticulous literature review was performed until the present day. We used 136 published manuscripts as our references. Both information from healthy individuals and descriptions of possible associations with systemic diseases are described. Additionally, it exposed information regarding several fields of ocular pathology, from cornea and ocular surface through areas of refractive surgery and glaucoma until vascular and structural diseases of the chorioretinal unit.

15.
Diabetes Metab Syndr Obes ; 14: 1281-1293, 2021.
Article in English | MEDLINE | ID: mdl-33776464

ABSTRACT

PURPOSE: To address the long-term visual function after bilateral pan-retinal photocoagulation (PRP) and its impact in real life, namely on visual field (VF) legal criteria to drive. To determine potential predictors related to clinical factors and treatment strategies. PATIENTS AND METHODS: Observational cross-sectional study. Eyes from diabetic patients diagnosed with diabetic retinopathy who underwent bilateral PRP, with or without macular treatments and with visual acuity legal criteria for non-professional driving were randomly assigned. Main outcomes were: demographic and clinical data including best corrected visual acuity; binocular visual field (EBST-Esterman Binocular Suprathreshold Test, Humphrey analyzer3®); contrast sensitivity (CS-Metrovision-MonPack3®); light scattering in the retina (HD Analyzer, Visiometrics®). RESULTS: Seventy-one diabetic patients included (44 men and 27 women), with a mean age of 62.2±11.8 years. PRP was performed, on average, 9.7±6.9 years before the study. The average EBST Score was 85.8±17.0 and the average CS (2-5cpd) was 19.5±2.9 dB in photopic and 14.2±4.1 dB in mesopic conditions. Through a multivariate regression model, after adjusting to the clinical and demographic factors as possible confounders, we found that treatment factors associated with worse results were the use of Argon laser for the EBST Score, the very confluent PRP for the number of non-viewed points in the central 30°x20° of the EBST and the presence of macular treatments for the CS tests. According to Portuguese law, 79% (n=56) of patients had minimal EBST amplitudes for non-professional driving. CONCLUSION: The functional results achieved in our sample are compatible with an active life, allowing most of the patients included to overcome the requirements of Portuguese legislation for driving light vehicles, namely at the level of the binocular visual field. These results highlight the role of PRP in the treatment of diabetic retinopathy in an era with evolving less aggressive laser options.

16.
Clin Ophthalmol ; 15: 1061-1071, 2021.
Article in English | MEDLINE | ID: mdl-33727788

ABSTRACT

PURPOSE: To compare the optic disc structure and peripapillary retinal function between high myopes with and without glaucoma and to address the differential role of papillary optical coherence tomography angiography (OCT-A) and circumpapillary microperimetry (cpMP) on the diagnosis and prognosis of this patients. PATIENTS AND METHODS: It is a cross-sectional study including 30 high myopic patients (60 eyes), divided into 15 with (GG) and 15 without glaucoma (NGG). Demographic and clinical data were collected from patient records. Papillary structure (peripapillary retinal nerve fiber layer thickness, ppRNFLTs) and vascularization (small vessel densities, SVD´s) were assessed with SD-OCT (RTVue XR Avanti, with AngioVue system, Optovue®). cpMP was carried out with the MP-3 microperimeter (Nidek®). RESULTS: The GG were older, had lower best-corrected visual acuities and higher intraocular pressures and axial lengths (p<0.001). The GG showed lower values in all ppRNFLTs (p<0.05), lower values in all SVDs (p<0.001), except the SVD-inside disc (p=0.638) and lower retinal sensitivities within all cpMPs (p<0.001). The adjusted analysis computing the best two parameters per exam revealed that the anatomical model including the ppRNFLT-inferior and ppRNFLT-temporal and the vascular model including SVD-inferior and SVD-superior had the best discrimination power between groups, with cross-validated AUROCs of 0.9599 and 0.9921, respectively. CONCLUSION: Despite the apparent superiority of the papillary vascular study, a multimodal approach including the papillary anatomic and circumpapillary microperimetric assessments can be the new way on the diagnosis and prognosis of glaucoma in high myopia.

17.
Clin Ophthalmol ; 15: 745-758, 2021.
Article in English | MEDLINE | ID: mdl-33642854

ABSTRACT

PURPOSE: To describe the tomographic and corneal biomechanical status of a sample of eyes excluded from LVC and to present the differences in biomechanical behavior in relation to cutoffs of clinical- and tomography-based screening methods used in clinical practice. PATIENTS AND METHODS: Observational cross-sectional study including 61 eyes from 32 consecutive patients who were excluded from LVC in our department. Clinical and demographic data were collected from the patients' clinical records. Tomographic data was assessed with a Scheimpflug camera (Pentacam, OCULUS®). Ablation depth (µm) and residual stromal bed (µm) were calculated by the WaveLight® EX500 laser system software (Alcon, EUA). The corneal biomechanical assessment was made through ultra-high speed Scheimpflug imaging during noncontact tonometry (Corvis ST, OCULUS®). Several ectasia risk scores were analyzed. RESULTS: Mean age was 31.0±6 years old and mean manifest spherical equivalent was -2.01 ± 2.3D. Belin-Ambrósio deviation index was the tomographic parameter with higher proportion of eyes within the ectasia high risk interval. In the biomechanical assessment, more than 95% of eyes met the criteria for ectasia susceptibility in four of the first generation and in two of the second generation parameters. In a cutoff based comparative analysis, eyes with Kmax ≥45.5 D, eyes with VCOMA <0 and eyes with ARTmax ≤350 presented significantly softer corneal biomechanical behavior. CONCLUSION: The majority of eyes excluded from LVC in the present study met the criteria for ectasia susceptibility in several biomechanical parameters, validating the clinical and tomographic based screening prior to LVC in our center. Differences found in the biomechanical assessment regarding cutoffs used in clinical practice highlight its differential role in characterizing risk profile of these patients. Tomography should not be overlooked and the integration of all data, including treatment-related parameters, can be the future of risk ectasia screening prior LVC.

18.
Int Med Case Rep J ; 14: 107-110, 2021.
Article in English | MEDLINE | ID: mdl-33633469

ABSTRACT

PURPOSE: To describe a rare case of an interface filamentous fungal keratitis and its successful clinical approach and management. PATIENTS AND METHODS: Retrospective case report. Analysis of the patient's clinical records. RESULTS: A healthy 30-year-old woman presenting with complaints of blurred vision, photophobia and intense pain, was previously diagnosed with a suspected unilateral diffuse lamellar keratitis after laser in situ keratomileusis surgery, and accordingly treated with a scheme of oral and subconjunctival corticosteroids. Due to worsening of symptoms, the patient was later referred to our ophthalmology department. Upon examination, a corneal infiltration was observed and a fungal infection was suspected. Treatment with fortified Voriconazole (1%) was initiated and both topical and oral corticosteroids were tapered. The infiltrate resolved after 6 weeks of antifungal topical treatment. Scopulariopsis brevicaulis was isolated on culture media. At the end of follow-up, the uncorrected distance visual acuity was 20/20 with mild scarring. CONCLUSION: Scopulariopsis brevicaulis can be associated with post-laser in situ keratomileusis interface infection. A quick intervention may dictate a good outcome, when combining early suspicion and microbiological diagnosis, and an appropriate conservative management. Furthermore, Voriconazole seems to be effective and safe in the treatment of such cases.

19.
Clin Ophthalmol ; 15: 235-242, 2021.
Article in English | MEDLINE | ID: mdl-33519185

ABSTRACT

PURPOSE: To characterize a population of high myopes with myopic traction maculopathy (MTM), to assess their retinal function, and to correlate it with anatomic status. PATIENTS AND METHODS: This was an observational cross-sectional study including 50 eyes from 27 patients. Demographic and clinical data were analyzed. Macular structure was assessed with spectral domain optical coherence tomography (SD-OCT, Heidelberg®) and macular function was studied with Microperimeter MP-3, NIDEK®. RESULTS: The average for central foveal thickness (CFT) and choroid thickness (CT) was 213±151 µm and 36±23 µm, respectively, in a total of 50 eyes from 27 patients. In the microperimetry analysis, the average sensitivity on the foveal-centered 12º polygon (CPS) was 14.37±9.1 dB. CT was negatively associated with the bivariate contour ellipse areas (BCEA) 1 (r=-0.314; p=0.034), 2 (r=-0.314; p=0.034), and 3 (r=-0.316; p=0.033). CPS had a strong positive correlation with best-corrected visual acuity (BCVA) (r=0.661; p=0.000). We found a trend to worse microperimetric results in eyes with schisis (n=19) (p>0.05) but eyes with atrophic areas (n=33) presented significant inferior CPS (p<0.001). The presence of staphyloma showed significant impact on macular sensitivities in eyes with areas of macular atrophy/fibrosis (p<0.05). CONCLUSION: Macular microperimetry analysis can have a role as part of a multimodal anatomo-functional assessment for a more precise characterization of the high myopic patients with MTM, optimizing medical and surgical decisions.

20.
Clin Ophthalmol ; 14: 4415-4421, 2020.
Article in English | MEDLINE | ID: mdl-33364746

ABSTRACT

PURPOSE: To describe the anatomical and functional results of the implantation of asymmetric thickness intracorneal ring segments (AS-ICRS) in eyes with keratoconus and asymmetric/irregular astigmatism (type 2 - Duck - and type 3 - Snowman - phenotypes, Fernandez-Vega/Alfonso morphologic Keratoconus classification). MATERIALS AND METHODS: Retrospective observational study including 19 consecutive patients (21 eyes) with keratoconus who underwent manual implantation of the Keraring® Asymmetric ICRS (AS). Analysis included demographic and clinical data and Pentacam (Oculus®) measurements: topographic astigmatism; topographic flat meridian (K1), steepest meridian (K2) and the maximum keratometric point (Kmax); total root mean square (RMS) and high order RMS (HOA) aberrations and comatic Zernike coefficients (Z31;Z3-1) at 0º and 90º meridians. RESULTS: Overall mean age was 35.3±11.7 years and median follow-up was 7.1 months (range 6-12). At the end of follow-up, a significant improvement from baseline was achieved in both UDVA (0.24±0.22; p=0.017) and CDVA (0.21±0.17; p<0.001). Regarding topographic measurements, the greatest decrease was observed in K2 (2.76±1.9D; p<0.001) and astigmatism (1.97±1.5; p<0.001). Aberrometry analysis showed a reduction of 1.27±3.2µm in the total RMS (p=0.085), 0.24±0.9µm in HOA (p=0.227) and 0.78±0.5 (p<0.001) in the 90º component of comatic aberration. The procedure effects in the CDVA, topographic and aberrometric parameters were higher in type 2 cones without statistical significance (p>0.05 in all). CONCLUSION: Implantation of the Keraring® Asymmetric ICRS in keratoconus with asymmetric/irregular astigmatism allowed an improvement of several clinical, topographic and aberrometric parameters, with clinical efficacy and safety, with a tendency to a greater effect in the type 2 cones.