Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Tex Heart Inst J ; 49(2)2022 03 01.
Article in English | MEDLINE | ID: mdl-35390164

ABSTRACT

Sixty years ago, 2 cardiac operations dramatically influenced the survival of patients with valvular heart disease. The replacement of an aortic valve by Dwight Harken and of a mitral valve by Albert Starr with mechanical caged-ball valves, both in 1960, was a true milestone in the history of cardiac surgery and the beginning of a long journey toward prosthetic valve replacement full of expectations, hopes, and dreams fulfilled. Caged-ball prostheses underwent numerous modifications in design and materials to improve reliability and prevent specific mechanical and thrombogenic complications. Clinical and pathologic experience gained during the past 6 decades has enabled the development of safe, durable, and minimally thrombogenic mechanical prostheses.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Diseases , Heart Valve Prosthesis , Aortic Valve , Cardiac Surgical Procedures/adverse effects , Heart Valve Diseases/surgery , Humans , Prosthesis Design , Reproducibility of Results
2.
Interact Cardiovasc Thorac Surg ; 24(5): 663-669, 2017 05 01.
Article in English | MEDLINE | ID: mdl-28329194

ABSTRACT

OBJECTIVES: Freedom Solo (FS) is a pericardial stentless heart valve showing excellent haemodynamic performance at mid-term. The aim of this study was to evaluate the long-term performance of such bioprostheses. METHODS: Between December 2004 and November 2009, 109 patients (31 men; mean age 76 ± 6 years) underwent aortic valve replacement with FS. Preoperatively, the mean NYHA class was 2.5 ± 0.7, the mean EuroSCORE II, 2.8 ± 2.5. Mean prosthesis size was 22.7 ± 1.9 mm; concomitant procedures were performed in 65 patients. Structural valve deterioration (SVD) was diagnosed according to the Valve Academic Research Consortium-2 definition. RESULTS: Two patients (1.8%) died within 30 days. Follow-up (72 ± 36 months) was 100% completed. The 1-, 5- and 10-year actuarial survival rates were 89, 73 and 42%, respectively, with 8 valve-related deaths; the actuarial freedom from SVD was 99, 93 and 76%. During 61 ± 39 months of follow-up, echocardiographic findings worsened progressively: At discharge, 3-5 and 7-9 years, the mean gradient was 8 ± 4, 12 ± 11 and 19 ± 19 mmHg ( P < 0.01); the indexed effective orifice area was 1.0 ± 0.2, 0.9 ± 0.2 and 0.8 ± 0.3 cm 2 /m 2 ( P < 0.01). Of the 13 patients who developed SVD, it was due to aortic stenosis in 11. SVD was a predictor of cardiovascular mortality at univariate analysis (HR 2.87, 1.12-7.29); 2 explanted prostheses showed massive calcium deposits with mean calcium and phosphorus contents of 234 ± 16 and 116 ± 7 mg/g dry weight, respectively. CONCLUSIONS: The FS bioprosthesis shows excellent mid-term clinical and haemodynamic results and offers an alternative to other valves, particularly in the case of a small aortic annulus. Worsening of FS performance was observed at late follow-up because of progressive SVD with stenosis, questioning whether it should be used in patients with a long life expectancy.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Forecasting , Heart Valve Prosthesis Implantation/methods , Hemodynamics/physiology , Pericardium/transplantation , Aged , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Echocardiography , Female , Follow-Up Studies , Humans , Italy/epidemiology , Male , Prosthesis Design , Survival Rate/trends , Treatment Outcome
3.
Virchows Arch ; 470(4): 455-463, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28220300

ABSTRACT

We analysed specificity and sensitivity of confocal laser microscopy (CLSM) on tissue sections for a diagnosis of amyloidosis, in an attempt to reduce technical errors and better standardise pathological diagnosis. We first set up a protocol for the use of CLSM on this type of specimen, using a group of 20 amyloid negative and 20 positive samples. Of all specimens, 2, 4 and 8-µm sections were cut. Sections were stained with Congo red (CR) and thioflavin-T (ThT) and observed by cross-polarised light microscopy (CR-PL), epifluorescence microscopy (CRF-epiFM and ThT-epiFM) and CLSM (CRF-CLSM and ThT-CLSM). To validate the method in a diagnostic setting, we examined tissue samples from 116 consecutive patients with clinical suspicion of amyloidosis, selected from the period 2005 to 2014 from the database of the Pathology Unit of the University of Padua. The results were compared with those of transmission electron microscopy (TEM), which we consider as reference. We found that with CRF-CLSM, the false negative rate was reduced from 17 to 5%, while the sensitivity of detection increased to 12%. The results were in complete agreement with those of TEM ThT-CLSM; both sensitivity and specificity were 100%. Finally, ThT-CLSM results did not vary with section thickness, and small amounts of amyloid could even be detected in 2-µm sections. In conclusion, we found ThT-CLSM to be more sensitive as a screening method for amyloidosis than CR and ThT epifluorescence optical imaging. The method was easier to standardise, provided images with better resolution and resulted in more consistent pathologist diagnoses.


Subject(s)
Amyloidosis/diagnosis , Microscopy, Confocal/methods , Coloring Agents , Congo Red , Female , Humans , Male , Microscopy, Electron, Transmission , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...