1.
Diseases ; 9(2)2021 May 05.
Article in English | MEDLINE | ID: mdl-34062996

ABSTRACT

In recent years, the digital polymerase chain reaction has received increasing interest as it has emerged as a tool to provide more sensitive and accurate detection of minimal residual disease. In order to start the process of data alignment, we assessed the consistency of the BCR-ABL1 quantification results of the analysis of 16 RNA samples at different levels of disease. The results were obtained by two different laboratories that relied on The Qx100/Qx200 Droplet Digital PCR System (Bio-Rad) and Quant Studio 3D dPCR System (Thermofisher) platforms. We assessed the compatibility between the estimated values by linear regression, Bland-Altman bias-plot, and Mann-Whitney nonparametric test. The results confirmed the compatibility of the measures, allowing us tocompute an 'alignment factor' (AF), equal to 1.41, which was further validated by a different series of experiments. We conclude that the performed measurements by the two laboratories are comparable, and also equalized through the introduction of an alignment factor.

2.
Microorganisms ; 8(7)2020 Jul 17.
Article in English | MEDLINE | ID: mdl-32708870

ABSTRACT

Rapid and sensitive screening of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential to limit the spread of the global pandemic we are facing. Quantitative real-time reverse transcription-polymerase chain reaction (qRT-PCR) is currently used for the clinical diagnosis of SARS-CoV-2 infection using nasopharyngeal swabs, tracheal aspirates, or bronchoalveolar lavage (BAL) samples. Despite the high sensitivity of the qRT-PCR method, false negative outcomes might occur, especially in patients with a low viral load. Here, we developed a multiplex qRT-PCR methodology for the simultaneous detection of SARS-CoV-2 genome (N gene) and of the human RNAse P gene as internal control. We found that multiplex qRT-PCR was effective in detecting SARS-Cov-2 infection in human specimens with 100% sensitivity. Notably, patients with few copies of SARS-CoV-2 RNA (<5 copies/reaction) were successfully detected by the novel multiplex qRT-PCR method. Finally, we assessed the efficacy of multiplex qRT-PCR on human nasopharyngeal swabs without RNA extraction. Collectively, our results provide evidence of a novel and reliable tool for SARS-CoV-2 RNA detection in human specimens, which allows the testing capacity to be expanded and the RNA extraction step to be bypassed.

3.
Cytokine ; 80: 43-7, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26945995

ABSTRACT

Obesity is an important health problem worldwide. Adipose tissue acts as an endocrine organ that secretes various bioactive substances, called adipokines, including pro-inflammatory biomarkers such as TNF-α, IL-6, leptin and C-reactive protein (CRP) and anti-inflammatory molecules such as adiponectin. The deregulated production of adipokines in obesity is linked to the pathogenesis of various disease processes and monitoring their variation is critical to understand metabolic diseases. The aim of this study was to determine the plasma concentration of adipokines in healthy subjects by multiplexed measurements and the effect of anticoagulants on their levels. Plasma samples from 10 healthy donors were collected in two different anticoagulants (sodium citrate or heparin). All markers, excluding TNF-α, showed significantly higher concentrations in heparinized compared to citrate plasma. However, levels of adipokines in different plasma samples were highly correlated for most of these markers. We reported that different anticoagulants used in the preparation of the plasma samples affected the measurements of some adipokines. The importance of the present results in epidemiology is relevant when comparing different studies in which blood samples were collected with different anticoagulants.


Subject(s)
Adipokines/blood , Anticoagulants/chemistry , Blood Specimen Collection , Adiponectin/blood , Adult , C-Reactive Protein/analysis , Citrates , Female , Healthy Volunteers , Heparin , Humans , Immunomagnetic Separation/methods , Interleukin-6/blood , Leptin/blood , Male , Sodium Citrate
4.
J Mol Diagn ; 17(6): 652-60, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26319783

ABSTRACT

Real-time quantitative PCR (qPCR) is a well-established tool for minimal residual disease (MRD) detection in mature lymphoid malignancies. Despite remarkable sensitivity and specificity, qPCR has some limitations, particularly in the need for a reference standard curve, based on target serial dilutions. In this study, we established droplet digital PCR (ddPCR) for MRD monitoring in multiple myeloma, mantle cell lymphoma, and follicular lymphoma and compared it head-to-head with qPCR. We observed that ddPCR has sensitivity, accuracy, and reproducibility comparable with qPCR. We then compared the two approaches in 69 patients with a documented molecular marker at diagnosis (18 multiple myelomas, 21 mantle cell lymphomas assessed with the immunoglobulin gene rearrangement, and 30 follicular lymphomas with the use of the BCL2/immunoglobulin gene major breakpoint region rearrangement). ddPCR was successful in 100% of cases, whereas qPCR failed to provide a reliable standard curve in three patients. Overall, 222 of 225 samples were evaluable by both methods. The comparison highlighted a good concordance (r = 0.94, P < 0.0001) with 189 of 222 samples (85.1%; 95% CI, 80.4%-89.8%) being fully concordant. We found that ddPCR is a reliable tool for MRD detection with greater applicability and reduced labor intensiveness than qPCR. It will be necessary to authorize ddPCR as an outcome predictor tool in controlled clinical settings and multilaboratory standardization programs.


Subject(s)
Lymphoma, Follicular/diagnosis , Lymphoma, Mantle-Cell/diagnosis , Multiple Myeloma/diagnosis , Neoplasm, Residual/diagnosis , Humans , Real-Time Polymerase Chain Reaction/methods , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
5.
PDA J Pharm Sci Technol ; 69(4): 540-52, 2015.
Article in English | MEDLINE | ID: mdl-26242789

ABSTRACT

UNLABELLED: During the validation of an additional working cell bank derived from a validated master cell bank to support the commercial production continuum of a recombinant protein, we observed an unexpected chromosomal location of the gene of interest in some end-of-production cells. This event-identified by fluorescence in situ hybridization and multicolour chromosome painting as a reciprocal translocation involving a chromosome region containing the gene of interest with its integral coding and flanking sequences-was unique, occurred probably during or prior to multicolour chromosome painting establishment, and was transmitted to the descending generations. Cells bearing the translocation had a transient and process-independent selective advantage, which did not affect process performance and product quality. However, this first report of a translocation affecting the gene of interest location in Chinese Hamster Ovary cells used for producing a biotherapeutic indicates the importance of the demonstration of the integrity of the gene of interest in end-of-production cells. LAY ABSTRACT: The expression of recombinant therapeutic proteins in mammalian cells depends on the establishment of a cell line with the gene of interest integrated in the host genome and stably expressed over time. Before being used for commercial production, cell lines are submitted to a qualification program in order to ensure their phenotypic and genotypic characteristics and the efficacy and safety of the product. During the production life cycle of a therapeutic protein, additional cells banks have to be validated after exhaustion of the current qualified cell bank in order to support the commercial production continuum of the recombinant protein. It is during the validation of an additional working cell bank derived from a validated master cell bank that we detected a different chromosome bearing the gene of interest in a portion of cells at the end of the upstream production phase. In our case, this event did not affect the process performance, the product quality, or its safety profile, but it highlights the need to characterize the integrity of the gene of interest in end-of-production cells when producing recombinant proteins for human use.


Subject(s)
Biological Products/metabolism , Biopharmaceutics/methods , CHO Cells , Chromosomes, Mammalian , Recombinant Proteins/biosynthesis , Translocation, Genetic , Animals , Bioreactors , Chromosome Painting , Cricetulus , Gene Expression Regulation , Humans , In Situ Hybridization, Fluorescence , Mice , Recombinant Proteins/genetics , Tetrahydrofolate Dehydrogenase/genetics , Tetrahydrofolate Dehydrogenase/metabolism , Transfection , Transgenes