Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 93(12): 123704, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36586927

ABSTRACT

The Ma_MISS spectrometer is integrated within the drilling system of the Rosalind Franklin ExoMars rover. This paper reports the on-ground calibration campaign performed on the spectrometer. Here, we focus on the spectral calibration of the instrument. The experimental setup used to carry out calibration is described, and the methods used for data processing and key parameters retrieval are explained. In particular, the spectral parameters such as (i) pixel central wavelengths, (ii) spectral response function, (iii) spectral resolution, (iv) sampling, and (v) range are determined. In a follow-up paper, the linearity and radiometric calibrations are described, while in De Sanctis et al. [Planet. Sci. J. 3, 142 (2022)], the validation of spectral measurements performed on synthetic and natural rock targets is presented.

2.
Rev Sci Instrum ; 88(9): 094503, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28964217

ABSTRACT

The Visible and near Infrared Hyperspectral Imager (VIHI) is the VIS-IR spectrometer with imaging capabilities aboard the ESA BepiColombo mission to Mercury. In this second paper, we report the instrument spectral characterization derived by the calibration campaign carried out before spacecraft integration. Complementary measurements concerning radiometric and linearity responses, as well as geometric performances, are described in Paper I [G. Filacchione et al., Rev. Sci. Instrum. 88, 094502 (2017)]. We have verified the VIHI spectral range, spectral dispersion, spectral response function, and spectral uniformity along the whole slit. Instrumental defects and optical aberrations due to smiling and keystone effects have been evaluated, and they are lower than the design requirement (<1/3 pixel). The instrumental response is uniform along the whole slit, while spectral dispersion is well represented by a second order curve, rather than to be constant along the spectral dimension.

3.
Appl Opt ; 38(18): 3945-50, 1999 Jun 20.
Article in English | MEDLINE | ID: mdl-18320003

ABSTRACT

As part of a feasibility study for a far-infrared Fourier-transform spaceborne spectrometer, the criteria that drive the choice of the instrument configuration have been identified as broadband operation, dual input and output ports, optics of the interferometer with full tilt compensation, and measurement of both planes of polarization of the source on a single detector. Despite the fact that some of these requirements are apparently difficult to reconcile, a new configuration of the polarizing interferometer that meets all the above requirements has been identified. The considerations that led to the design of this new configuration are discussed.

SELECTION OF CITATIONS
SEARCH DETAIL
...