Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Ann Med Surg (Lond) ; 49: 33-36, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31871681

ABSTRACT

INTRODUCTION: Even though is rarely, mandibular fracture after the extraction of third molars can occur in almost 1% of the procedures. Gender, age, position of third molar, tooth volume, bone fragility, systemic disorders, associated lesions, and degree of mandibular atrophy are factors that contribute to increase the incidence of fracture. The installation of the titanium miniplate during exodontia is an important tool to prevent the fracture. PRESENTATION OF CASE: The objective of this study is to present a clinical case of extraction of inferior impacted third molar, in atrophic mandible, with posterior installation of titanium miniplate, to prevent mandibular fracture. DISCUSSION AND CONCLUSION: preventive installation of titanium miniplate was effective and indeed prevented the mandibular fracture. No trans-operative or immediate post-operative complications were observed. Post-operative follow-up was of three years, with no complications, showing the success of the procedure.

2.
Rev. cuba. estomatol ; 54(4): 1-9, oct.-dic. 2017. ilus
Article in Spanish | LILACS | ID: biblio-901064

ABSTRACT

Introducción: la rehabilitación de pacientes desdentados mandibulares posteriores con implantes osteointegrados, se vuelve difícil cuando la cresta alveolar presenta una atrofia severa debido al recorrido superficial del canal mandibular. La lateralización del nervio dentario inferior es una alternativa terapéutica que posibilita la colocación de implantes convencionales y cortos en esta región. Objetivo: comparar la facilidad, efectividad y seguridad de la técnica quirúrgica convencional, realizada con fresas quirúrgicas, y la piezocirugía en la lateralización del nervio dentario inferior. Presentación del caso: paciente con ausencia bilateral de los molares inferiores y cresta alveolar atrófica fue tratada mediante lateralización del nervio dentario inferior y colocación simultánea de implantes. En el lado izquierdo, la lateralización fue realizada con fresas y en el lado derecho, con motor piezoeléctrico. Fue posible observar que la piezocirugía facilitó la técnica quirúrgica, y consecuentemente disminuyó el tiempo operatorio. A la vez, produjo una osteotomía más regular y con menos sangrado, lo cual mejoró la visualización del campo operatorio. Finalmente, el daño neural inmediato fue menor en el lado tratado con motor piezoeléctrico y con recuperación más rápida. Después de 3 meses de seguimiento, los implantes en ambos lados no presentaban pérdida ósea. Conclusiones: el uso del motor piezoeléctrico trajo más beneficios durante la lateralización del nervio dentario inferior, por la simplificación de la técnica quirúrgica y la reducción del sangrado y del daño neural en comparación con el uso de fresas convencionales(AU)


Introduction: the rehabilitation of edentulous posterior mandibular patients with bone-integrated implants becomes difficult when the alveolar crest presents a severe atrophy due to the superficial course of the mandibular canal. The inferior alveolar nerve lateralization is a therapeutic alternative that allows the placement of conventional and short implants in this region. Objective: to compare the easiness, effectiveness, and safety of the conventional surgical technique, performed with surgical drills, and piezosurgery in the lateralization of the inferior alveolar nerve. Case presentation: a patient with bilateral absence of the lower molars and atrophic alveolar crest was treated by lateralization of the inferior alveolar nerve and simultaneous implant placement. On the left side, the lateralization was made with drills and on the right side, with an electric piezotome. It was possible to observe that the piezosurgery facilitated the surgical technique, and consequently decreased the operative time. At the same time, it produced a more regular osteotomy and with less bleeding, which improved the visualization of the operative field. Finally, the immediate neural damage was lower on the side treated with the electric piezotome and with faster recovery. After 3 months of follow-up, the implants on both sides did not show bone loss. Conclusions: the use of the electric piezotome brought more benefits during the lateralization of the inferior alveolar nerve, by the simplification of the surgical technique and the reduction of bleeding and neural damage in comparison with the use of conventional drills(AU)


Subject(s)
Humans , Jaw, Edentulous/rehabilitation , Piezosurgery/instrumentation , Mandible , Dental Implants/adverse effects , Mandibular Reconstruction/rehabilitation
3.
Rev. cuba. estomatol ; 54(4): 1-9, oct.-dic. 2017. ilus
Article in Spanish | CUMED | ID: cum-72124

ABSTRACT

Introducción: la rehabilitación de pacientes desdentados mandibulares posteriores con implantes osteointegrados, se vuelve difícil cuando la cresta alveolar presenta una atrofia severa debido al recorrido superficial del canal mandibular. La lateralización del nervio dentario inferior es una alternativa terapéutica que posibilita la colocación de implantes convencionales y cortos en esta región. Objetivo: comparar la facilidad, efectividad y seguridad de la técnica quirúrgica convencional, realizada con fresas quirúrgicas, y la piezocirugía en la lateralización del nervio dentario inferior. Presentación del caso: paciente con ausencia bilateral de los molares inferiores y cresta alveolar atrófica fue tratada mediante lateralización del nervio dentario inferior y colocación simultánea de implantes. En el lado izquierdo, la lateralización fue realizada con fresas y en el lado derecho, con motor piezoeléctrico. Fue posible observar que la piezocirugía facilitó la técnica quirúrgica, y consecuentemente disminuyó el tiempo operatorio. A la vez, produjo una osteotomía más regular y con menos sangrado, lo cual mejoró la visualización del campo operatorio. Finalmente, el daño neural inmediato fue menor en el lado tratado con motor piezoeléctrico y con recuperación más rápida. Después de 3 meses de seguimiento, los implantes en ambos lados no presentaban pérdida ósea. Conclusiones: el uso del motor piezoeléctrico trajo más beneficios durante la lateralización del nervio dentario inferior, por la simplificación de la técnica quirúrgica y la reducción del sangrado y del daño neural en comparación con el uso de fresas convencionales(AU)


Introduction: the rehabilitation of edentulous posterior mandibular patients with bone-integrated implants becomes difficult when the alveolar crest presents a severe atrophy due to the superficial course of the mandibular canal. The inferior alveolar nerve lateralization is a therapeutic alternative that allows the placement of conventional and short implants in this region. Objective: to compare the easiness, effectiveness, and safety of the conventional surgical technique, performed with surgical drills, and piezosurgery in the lateralization of the inferior alveolar nerve. Case presentation: a patient with bilateral absence of the lower molars and atrophic alveolar crest was treated by lateralization of the inferior alveolar nerve and simultaneous implant placement. On the left side, the lateralization was made with drills and on the right side, with an electric piezotome. It was possible to observe that the piezosurgery facilitated the surgical technique, and consequently decreased the operative time. At the same time, it produced a more regular osteotomy and with less bleeding, which improved the visualization of the operative field. Finally, the immediate neural damage was lower on the side treated with the electric piezotome and with faster recovery. After 3 months of follow-up, the implants on both sides did not show bone loss. Conclusions: the use of the electric piezotome brought more benefits during the lateralization of the inferior alveolar nerve, by the simplification of the surgical technique and the reduction of bleeding and neural damage in comparison with the use of conventional drills(AU)


Subject(s)
Humans , Jaw, Edentulous/rehabilitation , Piezosurgery/instrumentation , Mandible , Dental Implants/adverse effects , Mandibular Reconstruction/rehabilitation
SELECTION OF CITATIONS
SEARCH DETAIL
...