Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1125(2): 195-203, 2006 Sep 01.
Article in English | MEDLINE | ID: mdl-16782111

ABSTRACT

A new ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method was developed to perform the determination of 16 mutagenic heterocyclic amines (HAs) in complex food samples in less than 2 min. The UPLC separation was carried out using an Acquity BEH C18 column (50 mm x 2.1 mm i.d., 1.7 microm particle size) that provided high efficiency and resolution in combination with high linear velocities. The UPLC system was coupled to the triple quadrupole Waters Micromass Quattro Premier. This system permits high-speed data acquisition without peak intensity degradation which is required to monitor the narrow chromatographic peaks (1-2 s) of HAs. The determination was performed in selected reaction monitoring (SRM) mode. The quality parameters of the developed method were established, obtaining instrumental LODs lower than 0.23 pg injected and a repeatability at low concentration level lower than 9.1% CV (n = 6). To evaluate the performance of the method in high throughput analysis of complex samples, the UPLC-MS/MS method was applied to the analysis of HAs in two meat extracts.


Subject(s)
Amines/analysis , Amines/chemistry , Chromatography, Liquid/methods , Food Analysis/methods , Heterocyclic Compounds/analysis , Meat Products/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Amines/isolation & purification , Animals , Heterocyclic Compounds/chemistry , Heterocyclic Compounds/isolation & purification , Hydrogen-Ion Concentration
2.
J Chromatogr A ; 1054(1-2): 409-18, 2004 Oct 29.
Article in English | MEDLINE | ID: mdl-15553170

ABSTRACT

This paper discusses the applicability of coupling liquid chromatography (LC) to mass spectrometry (MS) using a time-of-flight (TOF) mass analyzer for the analysis of heterocyclic amines (HAs). Accurate mass measurement (<2 mDa) with both MS-MS and in-source CID MS-MS was carried out to confirm the elemental composition of some fragments previously reported. Some isobaric assignments (fragments containing N versus CH2 and NH3 versus CD2H) were distinguished by taking advantage of the resolution provided by the TOF mass analyzer. On the other hand, the LC-MS analysis of HAs in MS acquisition mode was also performed. Quality parameters of the method were established. The linearity range extended over three orders of magnitude, limits of detection were in the pg level and good short-term precision values (R.S.D., 1.2-8.0%) were obtained. The LC-ESI-TOF method was applied to the determination of HAs in a lyophilized meat extract and the results obtained were comparable to those given by MS-MS with triple quadrupole and ion trap instruments.


Subject(s)
Amines/analysis , Chromatography, Liquid/methods , Heterocyclic Compounds/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Meat Products/analysis , Sensitivity and Specificity
3.
Article in English | MEDLINE | ID: mdl-15035996

ABSTRACT

Liquid chromatography coupled to mass spectrometry (LC-MS), especially by the use of electrospray ionisation source (ESI), is currently used for the analysis of heterocyclic aromatic amines (HAs) in complex samples. The present paper describes the study of the performance of different narrow-bore reversed-phase columns to achieve the best chromatographic separation for the determination of 16 HAs by LC-ESI-MS in food samples. Different parameters such as peak symmetry, resolution and number of theoretical plates have been evaluated for each column, using different chromatographic conditions. The column that provided the best results was TSK Gel Semi-Micro ODS-80TS of Tosohaas. Quality parameters have been established, obtaining good short-term precision in all cases (relative standard deviation (R.S.D.) lower than 7.7%) and low limits of detection (<13 pg injected in MS and <16 pg injected in MS/MS). The content of HAs in two beef extracts have been determined.


Subject(s)
Amines/analysis , Chromatography, Liquid/instrumentation , Heterocyclic Compounds/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Chromatography, Liquid/methods , Reproducibility of Results
4.
Article in English | MEDLINE | ID: mdl-15035997

ABSTRACT

The present paper describes the preparation of a suitable laboratory reference material (LRM) to validate analytical methods for the determination of heterocyclic amines (HAs) in foods. Three different lots of reference material were prepared using a beef extract which was contaminated with a well-known quantity of amines at different levels ranging from 10 to 75 ng/g. These materials were then lyophilised under determined conditions and, after grinding and sieving, homogenised and, finally, bottled and labelled. Homogeneity and stability studies were performed and no statistical differences were observed in the analysis of variances for within- and between-bottle results, thus demonstrating the homogeneity of the material. Stability at different storage temperatures (-18, +4, +25 and +40 degrees C) and times (1, 2, 3 and 6 months) was also tested. Therefore, the material can be considered homogeneous and stable and can be proposed for use in inter-comparison exercises for the determination of HAs.


Subject(s)
Amines/analysis , Heterocyclic Compounds/analysis , Meat/analysis , Animals , Cattle , Reference Standards
5.
Article in English | MEDLINE | ID: mdl-15035998

ABSTRACT

A feasibility study and two interlaboratory exercises on the determination of selected heterocyclic amines (HAs) in beef extract, organised in the framework of a European project, are presented. The aim of these exercises was to improve the quality of the laboratories and to evaluate the performance of a standardised analytical method and also the methods currently used by each of the participants for the analysis of these compounds. Three lyophilised portions of a commercial beef material previously spiked with HAs at different concentration levels ranging from 10 to 75 ng g(-1) were used as laboratory reference materials (lot A, B and C). Firstly, a feasibility study was carried out using a test standard solution and the beef extract (lot A), which contained only five HAs. Then, two interlaboratory exercises were carried out using the laboratory reference materials lot B and lot C, containing 10 selected HAs at two different concentration levels, 75 and 10 ng/g, respectively. The results obtained by all participant laboratories using the proposed method showed satisfactory agreement and the CV(%) between-laboratories obtained were from 8.3 to 24.1% for lot B and from 8.7 to 44.5% for lot C. The standardised method evaluated in these collaborative studies is therefore proposed for the analysis of HAs in food material. Moreover, LC-MS is recommended as the most suitable technique for the analysis of a large number of HAs in food samples.


Subject(s)
Amines/analysis , Food Analysis , Heterocyclic Compounds/analysis , Laboratories/organization & administration , Feasibility Studies
6.
J Chromatogr A ; 1023(1): 67-78, 2004 Jan 09.
Article in English | MEDLINE | ID: mdl-14760851

ABSTRACT

Three liquid chromatography-electrospray ionisation (LC-ESI) MS systems are evaluated for the analysis of heterocyclic amines (HAs). The electrospray sources and analysers (ion trap, single quadrupole and triple quadrupole) have been compared in terms of performance and quality parameters. In all cases, a C8 reversed-phase column and (acetic acid-ammonium acetate 30 mM pH 4.5)-acetonitrile (ACN) as mobile phase were used. Ionisation source parameters, post-column addition and working conditions for each acquisition mode (full scan, product ion scan, selected ion monitoring, and multiple reaction monitoring) were optimised for each instrument. The MS-MS spectra obtained with the ion trap and the triple quadrupole systems were very similar in both fragment ions and relative abundances, except for carbolines that showed adduct formation in the ion trap. Quality parameters were established and good precision (relative standard deviations (R.S.D.) < 12%) and very low limits of detection were obtained, mainly when using the triple quadrupole (< 9 pg injected). The content of HAs in a lyophilised beef extract was determined using the three instruments in order to compare their applicability for routine HAs analysis.


Subject(s)
Amines/analysis , Chromatography, Liquid/methods , Heterocyclic Compounds/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Freeze Drying , Meat Products/analysis , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...