1.
Int J Prosthodont
; 31(5): 492493, 2018.
Article
in English
| MEDLINE
| ID: mdl-29772031
ABSTRACT
PURPOSE: To compare the effects of different screw-tightening sequences and torque applications on stresses in implant-supported fixed complete dentures supported by five abutments. MATERIALS AND METHODS: Strain gauges fixed to the abutments were used to test the sequences 2-4-3-1-5; 1-2-3-4-5; 3-2-4-1-5; and 2-5-4-1-3 with direct 10-Ncm torque or progressive torque (5 + 10 Ncm). Data were analyzed using analysis of variance and standardized effect size. RESULTS: No effects of tightening sequence or torque application were found except for the sequence 3-2-4-1-5 and some small to moderate effect sizes. CONCLUSION: Screw-tightening sequences and torque application modes have only a marginal effect on residual stresses.