1.
Congenit Heart Dis ; 6(6): 665-7, 2011.
Article in English | MEDLINE | ID: mdl-21702889

ABSTRACT

Arrhythmias in adult congenital heart disease (ACHD) pose unique procedural challenges, especially with intravascular access. We report a unique case of ablation via a left-sided hepatic vein approach in a patient with situs inversus totalis. A 28-year-old woman with situs inversus totalis, ventriculoseptal defect, and dextro-transposition of the great arteries underwent ablation for documented narrow-complex tachycardia. Because of bilateral iliac venous occlusions, the coronary sinus (CS) was accessed through the left internal jugular vein. Rapid atrial pacing resulted in a tachycardia with an atrial cycle length of 225 msec and 2:1 atrioventricular association. Entrainment from the proximal and distal CS was consistent with typical atrial flutter around the left-sided tricuspid valve. Because of the iliac vein occlusions, access for ablation was obtained via a left-sided hepatic vein (Figure 1). Resetting from the cavotricuspid isthmus and three-dimensional electroanatomic mapping (Figure 2) confirmed typical atrial flutter, which, given the dextrocardia, occurred in a clockwise fashion around the tricuspid valve. Ablation was performed at the cavotricuspid isthmus resulting in arrhythmia termination and isthmus block. This case highlights the many unusual challenges that patients with ACHD can pose to the proceduralist, including atypical cardiac anatomy and difficult intravascular access. Unusual and creative approaches are often necessary to treat these patients successfully.


Subject(s)
Abnormalities, Multiple , Atrial Flutter/etiology , Heart Defects, Congenital/complications , Adult , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Cardiac Pacing, Artificial , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Female , Heart Defects, Congenital/surgery , Heart Septal Defects, Ventricular/complications , Humans , Predictive Value of Tests , Situs Inversus/complications , Transposition of Great Vessels/complications , Treatment Outcome
2.
Pacing Clin Electrophysiol ; 34(2): 186-92, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21039640

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) can provide life-saving therapies for ventricular arrhythmias. Arrhythmia induction and defibrillation threshold testing is often performed at implantation and postoperatively during long-term follow-up to ensure proper device function. METHODS: We sought to evaluate the prevalence and predictors of occult device malfunction at follow-up defibrillation testing in asymptomatic individuals. A cohort of 853 patients underwent 1,578 defibrillation tests during the 13-year study period. Defibrillation efficacy was evaluated primarily by the two-shock (2S) method, with an adequate safety margin ≥ 10 joules (J) less than the maximum energy delivered by the ICD. RESULTS: A total of 38 testing failures requiring intervention were discovered during testing (2.4% of all tests). There were 11 ICD system failures resulting in failure to defibrillate, six with underdetection of ventricular fibrillation, and 21 clinically significant increases in defibrillation threshold. There was a higher incidence of failure in older ICD systems (1996-2002) compared to newer ICD systems (2003-2009), reaching statistical significance (3.6% vs 1.0%; P < 0.01). There were 178 subjects (20.8%) with a >20-J safety margin on previous testing, detected R waves >7.0 mV, and all system components implanted after 2003 at the time of testing who did not have any testing failures (0% vs 5.6%; P < 0.01). CONCLUSION: Postoperative defibrillation testing identifies a small number of ICD malfunctions in asymptomatic individuals. ICD testing failure is seen more frequently in older systems and in those with borderline results from prior interrogation or testing. These findings suggest that serial postoperative defibrillation testing is not indicated in asymptomatic patients without suspicion for specific problems.


Subject(s)
Defibrillators, Implantable/statistics & numerical data , Equipment Failure Analysis/statistics & numerical data , Equipment Failure/statistics & numerical data , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/prevention & control , Adult , Aged , Colorado/epidemiology , Equipment Failure Analysis/methods , Female , Humans , Male , Middle Aged , Postoperative Care/methods , Postoperative Care/statistics & numerical data , Prevalence