Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Retina Vitreous ; 8(1): 86, 2022 Dec 28.
Article in English | MEDLINE | ID: mdl-36578074

ABSTRACT

PURPOSE: To report the clinical features, multi-modal imaging characteristics and their corroboration, and prognostic value of internal limiting membrane detachment (ILMD), a novel OCT biomarker in acute CRAO. DESIGN: Retrospective observational case-control study at institutional tertiary eye care centers. METHODS: 60 eyes of 60 patients of acute CRAO with optical coherence tomography (OCT) at baseline were included. Eyes were grouped in (a) With ILMD; (b) With no-ILMD. Multimodal imaging correlation, BCVA change and binary logistic regression were studied. RESULTS: Eighteen eyes (30%) were noted to have ILMD. At presentation, ILMD on OCT corroborated with macular non-perfusion with enlarged foveal avascular zone both on OCT-angiography (OCTA) and fundus fluorescein angiography (FFA). On follow-up, ILMD had resolved in all cases with fragmentation, disruption and atrophy of the retinal layers. Logistic regression showed poor baseline visual acuity was significantly associated with the odds of ILMD [Odds Ratio (OR) 31.02, p = 0.0018, 95% confidence interval: 1.81-529] while controlling for potential confounders including age (p = 0.60), gender (p = 0.316) duration of symptoms (p = 0.114), follow-up duration (p = 0.450) and final BCVA (p = 0.357). Eyes with ILMD and no-ILMD had a baseline BCVA of 2.62 LogMAR (light perception) and 2.05 LogMAR (Snellen equivalent 20/2000), respectively. On follow up, none of the eyes with ILMD showed any improvement. In contrast, nine (21.4%) eyes in no-ILMD had a vision of 20/400 and above with a mean final visual acuity of 1.87 + 0.78 LogMAR (p = 0.000). CONCLUSION: ILMD correlated with macular non-perfusion and poor baseline visual acuity which showed no improvement on follow-up, suggesting it to be poor prognostic biomarker.

2.
Transl Vis Sci Technol ; 7(3): 12, 2018 May.
Article in English | MEDLINE | ID: mdl-29881649

ABSTRACT

PURPOSE: To evaluate effectiveness of Welch Allyn Spot Vision Screener in detecting refractive error in all age groups and amblyopia risk factors in children in a tribal district of India. METHODS: All participants received dry retinoscopy and photorefraction; children also received cycloplegic retinoscopy. Statistical analysis included Bland-Altman and coefficient of determination (R2). RESULTS: Photoscreener could not elicit a response in 113 adults and 5 children of 580 recruited participants. In Bland-Altman analysis mean difference of Spot screener spherical equivalent (SSSE) and dry retinoscopy spherical equivalent (DRSE) was 0.32 diopters (D) in adults and 0.18 D in children; this was an overestimation of hyperopia and underestimation of myopia. In Bland-Altman analysis of SSSE and cycloplegic retinoscopy spherical equivalent (CRSE) the mean difference was -0.30 D in children; this was an overestimation of myopia and underestimation of hyperopia. In regression analysis the relationship between SSSE and DRSE was poor in adults (R2 = 0.50) and good in children (R2 = 0.92). Cubic regression model for Spot versus cycloretinoscopy in children was: CRSE = 0.34 + 0.85 SSSE - 0.01 SSSE2 + 0.006 SSSE3. It was 87% accurate. Sensitivity and specificity of Spot in detecting amblyopia risk factors (2013 American Association for Pediatric Ophthalmology and Strabismus [AAPOS] criteria) was 93.3% and 96.9% respectively. Sensitivity of Spot screener in detection of amblyopia was 72%. CONCLUSIONS: Photoscreener has 87% accuracy in refraction in children. Its value could be used for subjective correction tests. TRANSLATIONAL RELEVANCE: Photoscreening could complement traditional retinoscopy to address refractive error in children in a resource-limited facility region.

SELECTION OF CITATIONS
SEARCH DETAIL
...