Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Sensors (Basel) ; 23(6)2023 Mar 16.
Article in English | MEDLINE | ID: mdl-36991905

ABSTRACT

In this study, a review of second-generation voltage conveyor (VCII) and current conveyor (CCII) circuits for the conditioning of bio signals and sensors is presented. The CCII is the most known current-mode active block, able to overcome some of the limitations of the classical operational amplifier, which provides an output current instead of a voltage. The VCII is nothing more than the dual of the CCII, and for this reason it enjoys almost all the properties of the CCII but also provides an easy-to-read voltage as an output signal. A broad set of solutions for relevant sensors and biosensors employed in biomedical applications is considered. This ranges from the widespread resistive and capacitive electrochemical biosensors now used in glucose and cholesterol meters and in oximetry to more specific sensors such as ISFETs, SiPMs, and ultrasonic sensors, which are finding increasing applications. This paper also discusses the main benefits of this current-mode approach over the classical voltage-mode approach in the realization of readout circuits that can be used as electronic interfaces for different types of biosensors, including higher circuit simplicity, better low-noise and/or high-speed performance, and lower signal distortion and power consumption.


Subject(s)
Biosensing Techniques , Electronics
2.
Sensors (Basel) ; 23(3)2023 Feb 02.
Article in English | MEDLINE | ID: mdl-36772679

ABSTRACT

Sensor signals are physical, chemical, or biological quantities that evolve over time [...].

3.
Sensors (Basel) ; 22(22)2022 Nov 10.
Article in English | MEDLINE | ID: mdl-36433281

ABSTRACT

It is necessary to ensure safety in terms of health and accidents through the real-time monitoring of the construction site environment and workers. This problem has become of great importance due to the economic and social implications. Therefore, a sensor-based approach has been found to be beneficial in Building Information Modeling (BIM). Wireless Sensor Network (WSN) technologies are well-suited for the deployment of monitoring systems. A suitable technical solution for node communication in a WSN is Long Range (LoRa) modulation technology. In this study, an autonomous LoRa-based system for the monitoring of a construction site in Lungro, Calabria, Italy, is presented. The spatial monitoring of working personnel is achieved by employing a tracker device with an Inertial Measurement Unit (IMU) and a Global Positioning System (GPS) device. Accesses of personnel and gear to the site are registered using Radio Frequency Identification (RFID) tags equipped with protective gear. Fixed-position solar-powered sensor nodes are also employed for structural monitoring, i.e., movement sensors are used to monitor the variation of scaffolding, building structures, and under-work housing inclinations. Long Range Wide Area Network (LoRaWAN) gateways interface with the nodes and the internet for data exchange, enabling an Internet of Things (IoT) paradigm for the monitoring solution. A comprehensive overview of the workers and structural nodes, along with the RFID access management system and LoRaWAN gateway features, is provided in this article. A description of the web interface is also reported.


Subject(s)
Radio Frequency Identification Device , Wireless Technology , Humans , Monitoring, Physiologic , Technology , Italy
4.
Sensors (Basel) ; 22(9)2022 May 08.
Article in English | MEDLINE | ID: mdl-35591268

ABSTRACT

This study reviews second-generation voltage conveyor (VCII)-based read-out circuits for sensors and bioelectrical signal conditioning from existing literature. VCII is the dual circuit of a second-generation current conveyor (CCII), which provides the possibility of processing signals in the current domain while providing output signals in the voltage form. The scope of this paper is to discuss the benefits and opportunities of new VCII-based read-out circuits over traditional ones and bioelectrical signals. The achieved main benefits compared to conventional circuits are the simpler read-out circuits, producing an output signal in a voltage form that can be directly used, improved accuracy, possibility of gain adjustment using a single grounded resistor, and the possibility of connecting several SiPM sensors to the readout circuit. The circuits studied in this paper include VCII- based read-out circuits suitable for all types of sensors configured in the current-mode Wheatstone bridge (CMWB) topology, the VCII-based read-out circuits solutions reported for silicon photomultiplier, spiral-shaped ultrasonic PVDF and differential capacitive sensors, and, finally, a simple readout circuitry for sensing bioelectrical signals. There are still not many VCII-based readout circuits, and we hope that the outcome of this study will enhance this area of research and inspire new ideas.

5.
Sensors (Basel) ; 21(6)2021 Mar 23.
Article in English | MEDLINE | ID: mdl-33806723

ABSTRACT

Research on systems and circuits for interfacing sensors has always been, and will surely be, a highly prioritized, widespread, and lively topic [...].

6.
Sensors (Basel) ; 21(8)2021 Apr 15.
Article in English | MEDLINE | ID: mdl-33920787

ABSTRACT

The use of wearable sensors for health monitoring is rapidly growing. Over the past decade, wearable technology has gained much attention from the tech industry for commercial reasons and the interest of researchers and clinicians for reasons related to its potential benefit on patients' health. Wearable devices use advanced and specialized sensors able to monitor not only activity parameters, such as heart rate or step count, but also physiological parameters, such as heart electrical activity or blood pressure. Electrocardiogram (ECG) monitoring is becoming one of the most attractive health-related features of modern smartwatches, and, because cardiovascular disease (CVD) is one of the leading causes of death globally, the use of a smartwatch to monitor patients could greatly impact the disease outcomes on health care systems. Commercial wearable devices are able to record just single-lead ECG using a couple of metallic contact dry electrodes. This kind of measurement can be used only for arrhythmia diagnosis. For the diagnosis of other cardiac disorders, additional ECG leads are required. In this study, we characterized an electronic interface to be used with multiple contactless capacitive electrodes in order to develop a wearable ECG device able to perform several lead measurements. We verified the ability of the electronic interface to amplify differential biopotentials and to reject common-mode signals produced by electromagnetic interference (EMI). We developed a portable device based on the studied electronic interface that represents a prototype system for further developments. We evaluated the performances of the developed device. The signal-to-noise ratio of the output signal is favorable, and all the features needed for a clinical evaluation (P waves, QRS complexes and T waves) are clearly readable.


Subject(s)
Leg , Wearable Electronic Devices , Arrhythmias, Cardiac , Electrocardiography , Electrodes , Humans
7.
Micromachines (Basel) ; 12(2)2021 Jan 20.
Article in English | MEDLINE | ID: mdl-33498360

ABSTRACT

Exploiting the transmission and reception of low frequency ultrasounds in air is often associated with the innate echolocating abilities of some mammals, later emulated with sophisticated electronic systems, to obtain information about unstructured environments. Here, we present a novel approach for the reception of ultrasounds in air, which exploits a piezopolymer broadband sensor and an electronic interface based on a second-generation voltage conveyor (VCII). Taking advantage of its capability to manipulate both voltage and current signals, in this paper, we propose an extremely simple interface that presents a sensitivity level of about -100 dB, which is in line with commercially available references. The presented results are obtained without any filtration stage. The second-generation voltage conveyor active device is implemented through a commercially available AD844, with a supply voltage of ±15 V.

8.
Sensors (Basel) ; 20(7)2020 Apr 05.
Article in English | MEDLINE | ID: mdl-32260552

ABSTRACT

This work presents the design of a discrete second-generation voltage conveyor (VCII) and its capability to be used as electronic interface for silicon photomultipliers. The design addressed here exploits directly at the transistor level, with commercial components, the proposed interface; the obtained performance is valuable considering both the discrete elements and the application. The architecture adopted here realizes a transimpedance amplifier that is also able to drive very high input impedance, as usually requested by photons detection. Schematic and circuital design of the discrete second-generation voltage conveyor is presented and discussed. The complete circuit interface requires a bias current of 20 mA with a dual 5V supply voltage; it has a useful bandwidth of about 106 MHz, and considering also the reduced dimensions, it is a good candidate to be used in portable applications without the need of high-cost dedicated integrated circuits.

9.
Sensors (Basel) ; 20(2)2020 Jan 14.
Article in English | MEDLINE | ID: mdl-31947596

ABSTRACT

The three-dimensional printing of complex shapes without using supporting structures is the most attractive factor of merit in current additive manufacturing because it allows to drastically reduce printing time, and ideally nullify postprocessing and waste material. In this work, we present an innovative procedure and algorithm (Print on Air, PoA) for additive manufacturing that, relying on sensing systems embedded into the three-dimensional (3D) printer (e.g., temperature and speed sensors), aims at generating a printing sequence capable of a self-sustaining bridge and overhang structures. This feature was achieved by splitting the actual floating area of the layer where the aforementioned structures are in many subsections. Each is generated with a negligible floating surface and printed in a well-determined sequence with accurate temperature and speed profiles. Therefore, each subsection is formed without the need for scaffolding, simultaneously acting as a supporting structure for the following subsection. The array of subsections constitutes the actual bridge or overhang structure. The proposed method can be used for any object, including very long bridges or convex surfaces. The revolutionary method is here reported and evaluated in order to show its applicability in any condition. Although the study was conducted in a Fused Deposition Material (FDM) environment, it can certainly be adapted to other manufacturing environments with adequate modifications.

10.
Sensors (Basel) ; 19(16)2019 Aug 14.
Article in English | MEDLINE | ID: mdl-31416211

ABSTRACT

In this paper, a novel approach to implement a stray insensitive CMOS interface for differential capacitive sensors is presented. The proposed circuit employs, for the first time, second-generation voltage conveyors (VCIIs) and produces an output voltage proportional to differential capacitor changes. Using VCIIs as active devices inherently allows the circuit to process the signal in the current domain, and hence, to benefit from its intrinsic advantages, such as high speed and simple implementation, while still being able to natively interface with voltage mode signal processing stages at necessity. The insensitiveness to the effects of parasitic capacitances is achieved through a simple feedback loop. In addition, the proposed circuit shows a very simple and switch-free structure (which can be used for both linear and hyperbolic sensors), improving its accuracy. The readout circuit was designed in a standard 0.35 µm CMOS technology under a supply voltage of ±1.65 V. Before the integrated circuit fabrication, to produce tangible proof of the effectiveness of the proposed architecture, a discrete version of the circuit was also prototyped using AD844 and LF411 to implement a discrete VCII. The achieved measurement results are in good agreement with theory and simulations, showing a constant sensitivity up to 412 mV/pF, a maximum linearity error of 1.9%FS, and acknowledging a good behavior with low baseline capacitive sensors (10 pF in the proposed measurements). A final table is also given to summarize the key specs of the proposed work comparing them to the available literature.

11.
Micromachines (Basel) ; 9(10)2018 Oct 08.
Article in English | MEDLINE | ID: mdl-30424440

ABSTRACT

In this manuscript, the authors propose a novel interface for silicon photomultipliers based on a second-generation voltage conveyor as an active element, performing as a transimpedance amplifier. Due to the absence of internal feedback, this solution offers a static bandwidth regardless of the tunable gain level. The simulation results have shown good performances, confirming the possibility of the proposed interface being effectively used in different scenarios. A preliminary hybrid solution has also been developed using second-generation current conveyors and measurements conducted on an equivalent discrete-elements board, which is promising.

SELECTION OF CITATIONS
SEARCH DETAIL
...