Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
1.
J Clin Pathol ; 75(9): 612-619, 2022 Sep.
Article in English | MEDLINE | ID: mdl-33952592

ABSTRACT

AIMS: In advanced-stage non-small-cell lung cancer (NSCLC), incomplete genotyping for guideline-recommended genomic biomarkers poses a significant challenge to making informed and timely clinical decisions. We report our institution's experience in assessing the adequacy of small specimens for comprehensive genomic profiling for guideline-recommended lung cancer biomarker testing. METHODS: We performed a retrospective evaluation of all image-guided procedures for NSCLC performed in our institution between October 2016 and July 2018, including core needle biopsy (CNB) and fine-needle aspiration (FNA) in patients who had undergone genomic profiling for lung cancer. Lung cancer biomarker adequacy, defined as successful testing of guideline-recommended biomarkers including, epidermal growth factor receptor (EGFR); serine/threonine protein kinase B-Raf (BRAF); anaplastic lymphoma kinase (ALK); proto-oncogene tyrosine protein kinase ROS (ROS1); Rearranged during Transfection (RET); Tyrosine protein kinase Met (MET); and programmed cell death ligand 1 (PD-L1), was evaluated. RESULTS: A total of 865 cases were evaluated in this study, 785 of which included testing of all lung cancer biomarkers. Lung tissue was adequate for biomarker testing in 84% of cases; this rate increased to 87% when biomarker testing was combined with concurrently acquired FNA or CNB specimens. Biomarker testing success correlated strongly with DNA concentration (p<0.0001) and the use of 22G needles in endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) procedures (p=0.0035). Biomarker testing of CNB specimens showed a significantly higher success rate than did biomarker testing of cytology FNA specimens (p=0.0005). The adequacy of EBUS-TBNA samples was not significantly different from that of the transthoracic needle aspiration samples (p=0.40). Variables such as age, gender, lesion size, site, diagnosis and number of needle passes showed no significant correlation with success rates in lung cancer biomarker testing. CONCLUSION: The growing numbers of therapeutic biomarkers in NSCLC requires judicious triage of limited-volume tissue from small specimens. Our study showed that thoracic small tissue specimens can be used successfully to provide prognostic and predictive information for the current guideline-recommended biomarkers for NSCLC in most cases.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Biomarkers, Tumor/genetics , Carcinoma, Non-Small-Cell Lung/diagnosis , Carcinoma, Non-Small-Cell Lung/genetics , Carcinoma, Non-Small-Cell Lung/therapy , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Genomics , Humans , Immune Checkpoint Inhibitors , Lung Neoplasms/diagnosis , Lung Neoplasms/genetics , Lung Neoplasms/therapy , Protein-Tyrosine Kinases , Proto-Oncogene Proteins/genetics , Retrospective Studies
2.
Arch Pathol Lab Med ; 145(11): 1405-1412, 2021 11 01.
Article in English | MEDLINE | ID: mdl-33493304

ABSTRACT

CONTEXT.­: RNA-based next-generation sequencing (NGS) assays are being used with increasing frequency for comprehensive molecular profiling of solid tumors. OBJECTIVE.­: To evaluate factors that might impact clinical assay performance. DESIGN.­: A 4-month retrospective review of cases analyzed by a targeted RNA-based NGS assay to detect fusions was performed. RNA extraction was performed from formalin-fixed, paraffin-embedded tissue sections and/or cytology smears of 767 cases, including 493 in-house and 274 outside referral cases. The types of samples included 422 core needle biopsy specimens (55%), 268 resection specimens (35%), and 77 cytology samples (10%). RESULTS.­: Successful NGS fusion testing was achieved in 697 specimens (90.9%) and correlated positively with RNA yield (P < .001) and negatively with specimen necrosis (P = .002), decalcification (P < .001), and paraffin block age of more than 2 years (P = .001). Of the 697 cases that were successfully sequenced, 50 (7.2%) had clinically relevant fusions. The testing success rates and fusion detection rates were similar between core needle biopsy and cytology samples. In contrast, RNA fusion testing was often less successful using resection specimens (P = .007). Testing success was independent of the tumor percentage in the specimen, given that at least 20% tumor cellularity was present. CONCLUSIONS.­: The success of RNA-based NGS testing is multifactorial and is influenced by RNA quality and quantity. Identification of preanalytical factors affecting RNA quality and yield can improve NGS testing success rates.


Subject(s)
Biomarkers, Tumor/genetics , Gene Expression Profiling , Gene Fusion , High-Throughput Nucleotide Sequencing , Neoplasms/genetics , RNA, Neoplasm/genetics , Sequence Analysis, RNA , Transcriptome , Adolescent , Adult , Aged , Aged, 80 and over , Biopsy , Child , Databases, Factual , Female , Humans , Male , Middle Aged , Neoplasms/pathology , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Young Adult
3.
Cancer Cytopathol ; 129(5): 374-382, 2021 05.
Article in English | MEDLINE | ID: mdl-33119213

ABSTRACT

BACKGROUND: The use of RNA-based next-generation sequencing (NGS) assays to detect gene fusions for targeted therapy has rapidly become an essential component of comprehensive molecular profiling. For cytology specimens, the cell block (CB) is most commonly used for fusion testing; however, insufficient cellularity and/or suboptimal RNA quality are often limiting factors. In the current study, the authors evaluated the factors affecting RNA fusion testing in cytology and the added value of smears in cases with a suboptimal or inadequate CB. METHODS: A 12-month retrospective review was performed to identify cytology cases that were evaluated by a targeted RNA-based NGS assay. Samples were sequenced by targeted amplicon-based NGS for 51 clinically relevant genes on a proprietary platform. Preanalytic factors and NGS quality parameters were correlated with the results of RNA fusion testing. RESULTS: The overall success rate of RNA fusion testing was 92%. Of the 146 cases successfully sequenced, 14% had a clinically relevant fusion detected. NGS testing success positively correlated with RNA yield (P = .03) but was independent of the tumor fraction, the tumor size, or the number of slides used for extraction. CB preparations were adequate for testing in 45% cases, but the inclusion of direct smears increased the adequacy rate to 92%. There was no significant difference in testing success rates between smears and CB preparations. CONCLUSIONS: The success of RNA-based NGS fusion testing depends on the quality and quantity of RNA extracted. The use of direct smears significantly improves the adequacy of cytologic samples for RNA fusion testing for predictive biomarkers.


Subject(s)
Biomarkers, Tumor/genetics , Cytodiagnosis/methods , Cytological Techniques/methods , Gene Fusion , High-Throughput Nucleotide Sequencing/methods , Neoplasms/diagnosis , Adult , Aged , Aged, 80 and over , Biopsy, Fine-Needle , Female , Humans , Male , Middle Aged , Neoplasms/genetics , Retrospective Studies
4.
J Natl Compr Canc Netw ; 18(10): 1300-1304, 2020 10.
Article in English | MEDLINE | ID: mdl-33022638

ABSTRACT

RNA-seq was used to identify the partner gene and confirm the presence of a BCR-PDGFRB fusion. Identification of this fusion product resulted in successful treatment and long-term remission of this myeloid neoplasm. Based on our results, we suggest that despite current WHO recommendations, screening for PDGFRB rearrangement in cases of leukocytosis with eosinophilia and no other etiologic explanation is necessary, even if the karyotype is normal.


Subject(s)
Eosinophilia , Myeloproliferative Disorders , Neoplasms , Oncogene Proteins, Fusion/genetics , Eosinophilia/diagnosis , Eosinophilia/genetics , Humans , Imatinib Mesylate , Myeloproliferative Disorders/complications , Myeloproliferative Disorders/diagnosis , Myeloproliferative Disorders/genetics , Neoplasms/diagnosis , Neoplasms/genetics , Receptor, Platelet-Derived Growth Factor beta/genetics , Translocation, Genetic
5.
Cancer Cytopathol ; 127(3): 146-160, 2019 03.
Article in English | MEDLINE | ID: mdl-30620446

ABSTRACT

BACKGROUND: Molecular testing is recommended as an adjunct to improve the preoperative diagnosis of fine-needle aspiration (FNA) of thyroid nodules. Centrifuged supernatants from FNA samples, which are typically discarded, have recently emerged as a novel liquid-based biopsy for molecular testing. This study evaluates the use of thyroid FNA supernatants for detecting clinically relevant mutations. METHODS: Supernatants from thyroid FNA samples (n = 156) were evaluated. A 50-gene next-generation sequencing (NGS) assay was used, and mutation analysis results from a subset of samples were further compared with those of paired FNA smears and/or cell blocks. RESULTS: All 156 samples yielded adequate DNA (median, 135 ng; range, 11-3180 ng), and 129 of these samples (83%) were successfully sequenced by NGS. The most frequently detected somatic mutations included BRAF and RAS mutations, which were followed by RET, TP53, PTEN, CDKN2A, and PIK3CA mutations. Eleven of 31 cases with an indeterminate cytologic diagnosis and 9 of 12 cases that were suspicious for malignancy had somatic mutations, including the BRAF V600E mutation, which is highly definitive for papillary thyroid carcinoma (PTC). Seven of the 9 indeterminate and suspicious cases with the BRAF V600E mutation had surgical follow-up, and they were all confirmed to be PTC. A comparison of the mutation profiles derived from supernatants with those of paired smears and/or cell blocks in a small subset of cases (n = 8) showed 100% concordance. CONCLUSIONS: This study provides evidence that FNA supernatants can be used as a surrogate for thyroid molecular testing to improve diagnostic accuracy in indeterminate nodules, provide prognostic/predictive information, and improve overall patient management.


Subject(s)
Biopsy, Fine-Needle/methods , High-Throughput Nucleotide Sequencing/methods , Liquid Biopsy/methods , Thyroid Gland/metabolism , Thyroid Nodule/genetics , Centrifugation/methods , Genetic Predisposition to Disease/genetics , Genetic Testing/methods , Humans , Mutation , Prognosis , Reproducibility of Results , Sensitivity and Specificity , Thyroid Gland/pathology , Thyroid Neoplasms/genetics , Thyroid Neoplasms/metabolism , Thyroid Neoplasms/pathology , Thyroid Nodule/diagnosis , Thyroid Nodule/metabolism
6.
Mod Pathol ; 32(3): 405-414, 2019 03.
Article in English | MEDLINE | ID: mdl-30315273

ABSTRACT

There is currently no blood-based marker in routine use for endometrial cancer patients. Such a marker could potentially be used for early detection, but it could also help to track tumor recurrence following hysterectomy. This is important, as extra-vaginal recurrence of endometrial endometrioid adenocarcinoma is usually incurable. This proof-of-principle study was designed to determine if tumor-associated mutations could be detected in cell-free DNA from the peripheral blood of early and late stage endometrial endometrioid carcinoma patients. Approximately 90% of endometrioid carcinomas have at least one mutation in the genes CTNNB1, KRAS, PTEN, or PIK3CA. Using a custom panel targeting 30 hotspot amplicons in these four genes, next-generation sequencing was performed on cell-free DNA extracted from plasma obtained from a peripheral blood draw at the time of hysterectomy and the matching tumor DNA from 48 patients with endometrioid endometrial carcinomas. At least one mutation in the tumor was detected in 45/48 (94%) of patients. Fifteen of 45 patients (33%) had a mutation in the plasma that matched a mutation in the tumor. These same mutations were not detected in the matched negative control buffy coat. Presence of a plasma mutation was significantly associated with advanced stage at hysterectomy, deep myometrial invasion, lymphatic/vascular invasion, and primary tumor size. Detecting a plasma-based mutation was independent of the amount of cell-free DNA isolated from the plasma. Overall, 18% of early stage patients had a mutation detected in the plasma. These results demonstrate that mutations in genes relevant to endometrial cancer can be identified in the peripheral blood of patients at the time of surgery. Future studies can help to determine the post-operative time course of mutation clearance from the peripheral blood and if mutation re-emergence is predictive of recurrence.


Subject(s)
Biomarkers, Tumor/blood , Biomarkers, Tumor/genetics , Carcinoma, Endometrioid/genetics , Circulating Tumor DNA/genetics , Endometrial Neoplasms/genetics , Adult , Aged , Aged, 80 and over , Carcinoma, Endometrioid/blood , Carcinoma, Endometrioid/diagnosis , Circulating Tumor DNA/blood , Endometrial Neoplasms/blood , Endometrial Neoplasms/diagnosis , Female , High-Throughput Nucleotide Sequencing , Humans , Middle Aged , Mutation , Neoplasm Recurrence, Local/diagnosis
7.
J Mol Diagn ; 21(1): 89-98, 2019 01.
Article in English | MEDLINE | ID: mdl-30577887

ABSTRACT

Next-generation sequencing (NGS)-based mutation panels profile multiple genes simultaneously, allowing the reporting of numerous genes while saving labor and resources. However, one drawback of using NGS is that the turnaround time is often longer than conventional single gene tests. This delay can be problematic if molecular results are required to guide therapy in patients with clinically aggressive diseases, such as acute myeloid leukemia. To overcome this limitation, we developed a novel custom platform designated as Ultra-rapid Reporting of GENomic Targets (URGENTseq), an integrated solution that includes workflow optimization and an innovative custom bioinformatics pipeline to provide targeted NGS results on fresh peripheral blood and bone marrow samples within an actionable time period. URGENTseq was validated for clinical use by determining mutant allelic frequency and minimum coverage in silico to achieve 100% concordance for all positive and negative calls between the URGENTseq and conventional sequencing approach. URGENTseq enables the reporting of selected genes useful for immediate diagnosis (CALR, CSF3R, JAK2, KRAS, MPL, NPM1, NRAS, SF3B1) and treatment decisions (IDH1, IDH2) in hematologic malignancies within 48 hours of specimen collection. In addition, we summarize the molecular findings of the first 272 clinical test results performed using the URGENTseq platform.


Subject(s)
Genomics/methods , High-Throughput Nucleotide Sequencing/methods , Genetic Testing/economics , Genetic Testing/methods , Genetic Variation , Genomics/economics , High-Throughput Nucleotide Sequencing/economics , Humans , Nucleophosmin , Time Factors , Workflow
8.
PLoS One ; 13(9): e0204218, 2018.
Article in English | MEDLINE | ID: mdl-30222780

ABSTRACT

ASXL1 (additional sex combs like 1) is a gene that is mutated in a number of hematological neoplasms. The most common genetic alteration is c.1934dupG p.Gly646fs. Previous publications have shown that ASXL1 mutations have a negative prognostic impact in patients with MDS and AML, however, controversy exists regarding the molecular testing of ASXL1 c.1934dupG as polymerase splippage over the adjacent homopolymer could lead to a false-positive result. Here, we report the first study to systematically test different targeted next generation sequencing (NGS) approaches for this mutation in patients with hematologic neoplasms. In addition, we investigated the impact of proofreading capabilities of different DNA polymerases on ASXL1 c.1934dupG somatic mutation using conventional Sanger sequencing, another common method for ASXL1 genotyping. Our results confirm that ASXL1 c.1934dupG can be detected as a technical artifact, which can be overcome by the use of appropriate enzymes and library preparation methods. A systematic study of serial samples from 30 patients show that ASXL1 c.1934dupG is a somatic mutation in haematological neoplasms including MDS, AML, MPN and MDS/MPN and often is associated with somatic mutations of TET2, EZH2, IDH2, RUNX1, NRAS and DNMT3A. The pattern of clonal evolution suggests that this ASXL1 mutation might be an early mutational event that occurs in the principal clonal population and can serve as a clonal marker for persistent/relapsing disease.


Subject(s)
Hematologic Neoplasms/diagnosis , High-Throughput Nucleotide Sequencing/methods , Mutation , Repressor Proteins/genetics , Sequence Analysis, DNA/methods , Aged , Biomarkers, Tumor/genetics , Clonal Evolution , Early Detection of Cancer , False Positive Reactions , Female , Gene Frequency , Gene Regulatory Networks , Hematologic Neoplasms/genetics , Humans , Male , Middle Aged , Molecular Diagnostic Techniques , Prognosis , Recurrence
9.
Oncotarget ; 9(12): 10259-10271, 2018 02 13.
Article in English | MEDLINE | ID: mdl-29535804

ABSTRACT

A suitable clinical-grade platform is required for detection of somatic mutations with high sensitivity in cell-free DNA (cfDNA) of patients with solid tumors. In this study, we evaluated in parallel ultra-deep NGS with MassARRAY and allele-specific droplet digital PCR (ddPCR) for cfDNA genotyping and correlated cfDNA yield and mutation status with overall survival (OS) of patients. We assessed plasma samples from 46 patients with various advanced metastatic solid tumors and known mutations by deep sequencing using an Ampliseq cancer hotspot panel V2 on Ion Proton. A subset of these samples with DNA availability was tested by ddPCR and UltraSEEK MassARRAY for mutation detection in 5 genes (IDH1, PIK3CA, KRAS, BRAF, and NRAS). Sixty one of 104 expected tissue mutations and 6 additional mutations not present in the tissue were detected in cfDNA. ddPCR and MassARRAY showed 83% and 77% concordance with NGS for mutation detection with 100% and 79% sensitivity, respectively. The median OS of patients with lower cfDNA yield (74 vs 50 months; P < 0.03) and cfDNA negative for mutations (74.2 vs 53 months; p < 0.04) was significantly longer than in patients with higher cfDNA yield and positive for mutations. A limit-of-detection of 0.1% was demonstrated for ddPCR and MassARRAY platforms using a serially diluted positive cfDNA sample. The MassARRAY and ddPCR systems enable fast and cost-effective genotyping for a targeted set of mutations and can be used for single gene testing to guide response to chemotherapy or for orthogonal validation of NGS results.

10.
Mod Pathol ; 31(7): 1036-1045, 2018 07.
Article in English | MEDLINE | ID: mdl-29463880

ABSTRACT

With the expanding role of targeted therapy in patients with solid tumors, pathologists face the daunting task of having to maximize limited volume tissue obtained by fine needle aspiration for a variety of molecular tests. While most molecular studies on fine needle aspiration samples have been reported using cellular material, recent studies have shown that a substantial amount of DNA can be retrieved from the supernatant fluid of aspirate needle rinses after cell pelleting for cytospin or cell block preparations. In routine clinical workflow, the supernatant is discarded; however this fluid may provide a complementary source of DNA for tumor mutational profiling. In this study, we evaluated the post-centrifuged supernatant from 25 malignant and 10 benign fine needle aspiration needle rinses. The mean and median DNA yields from the supernatants were 445 ng and 176.4 ng (range, 15.1-2958 ng), respectively. Next generation sequencing using the Ion AmpliSeq Cancer Hotspot Panel v2 detected somatic mutations in all 25 malignant samples. No mutations were detected in any of the benign samples tested. When available, mutations detected in the supernatant fluid were compared to the next generation sequencing analysis performed on a prior or concurrent surgical specimen from the same patient and showed 100% concordance. In a subset of cases (n = 19) mutations in EGFR, KRAS, BRAF, PIK3CA, and NRAS were successfully confirmed by droplet digital PCR, providing an orthogonal platform for mutation analysis. In summary, in this study we show that post centrifuged supernatants from fine needle aspiration needle rinses can provide a robust substrate for expanded mutation profiling by next generation sequencing, as well as hotspot mutation testing by droplet digital PCR. The ability to detect somatic mutations from otherwise discarded supernatant fluids offers the ability to triage and effectively utilize limited volume fine needle aspiration samples when multiple molecular tests are requested, without the need to re-biopsy for additional tissue samples.


Subject(s)
Biopsy, Fine-Needle/methods , DNA Mutational Analysis/methods , DNA, Neoplasm/isolation & purification , Specimen Handling/methods , Biomarkers, Tumor/genetics , Biomarkers, Tumor/isolation & purification , Centrifugation , DNA, Neoplasm/analysis , Gene Expression Profiling/methods , High-Throughput Nucleotide Sequencing , Humans , Neoplasms/genetics
11.
PLoS One ; 12(8): e0181968, 2017.
Article in English | MEDLINE | ID: mdl-28767674

ABSTRACT

BACKGROUND: Next generation sequencing based tumor tissue genotyping involves complex workflow and a relatively longer turnaround time. Semiconductor based next generation platforms varied from low throughput Ion PGM to high throughput Ion Proton and Ion S5XL sequencer. In this study, we compared Ion PGM and Ion Proton, with a new Ion S5XL NGS system for workflow scalability, analytical sensitivity and specificity, turnaround time and sequencing performance in a clinical laboratory. METHODS: Eighteen solid tumor samples positive for various mutations as detected previously by Ion PGM and Ion Proton were selected for study. Libraries were prepared using DNA (range10-40ng) from micro-dissected formalin-fixed, paraffin-embedded (FFPE) specimens using the Ion Ampliseq Library Kit 2.0 for comprehensive cancer (CCP), oncomine comprehensive cancer (OCP) and cancer hotspot panel v2 (CHPv2) panel as per manufacturer's instructions. The CHPv2 were sequenced using Ion PGM whereas CCP and OCP were sequenced using Ion Proton respectively. All the three libraries were further sequenced individually (S540) or multiplexed (S530) using Ion S5XL. For S5XL, Ion chef was used to automate template preparation, enrichment of ion spheres and chip loading. Data analysis was performed using Torrent Suite 4.6 software on board S5XL and Ion Reporter. A limit of detection and reproducibility studies was performed using serially diluted DLD1 cell line. RESULTS: A total of 241 variant calls (235 single nucleotide variants and 6 indels) expected in the studied cohort were successfully detected by S5XL with 100% and 97% concordance with Ion PGM and Proton, respectively. Sequencing run time was reduced from 4.5 to 2.5 hours with output range of 3-5 GB (S530) and 8-9.3Gb (S540). Data analysis time for the Ion S5XL is faster 1 h (S520), 2.5 h (S530) and 5 h (S540) chip, respectively as compared to the Ion PGM (3.5-5 h) and Ion Proton (8h). A limit detection of 5% allelic frequency was established along with high inter-run reproducibility. CONCLUSION: Ion S5XL system simplified workflow in a clinical laboratory, was feasible for running smaller and larger panels on the same instrument, had a shorter turnaround time, and showed good concordance for variant calls with similar sensitivity and reproducibility as the Ion PGM and Proton.


Subject(s)
DNA, Neoplasm/analysis , High-Throughput Nucleotide Sequencing/instrumentation , Neoplasms/genetics , Sequence Analysis, DNA/instrumentation , Adult , Aged , Clinical Laboratory Services , Female , Humans , Male , Middle Aged , Mutation , Sensitivity and Specificity , Software , Time Factors , Young Adult
12.
J Mol Diagn ; 19(4): 514-524, 2017 07.
Article in English | MEDLINE | ID: mdl-28506684

ABSTRACT

Detection of mutations in plasma circulating cell-free DNA (cfDNA) by next-generation sequencing (NGS) has opened up new possibilities for monitoring treatment response and disease progression in patients with solid tumors. However, implementation of cfDNA genotyping in diagnostic laboratories requires systematic assessment of preanalytical parameters and analytical performance of NGS platforms. We assessed the effects of peripheral blood collection tube and plasma separation time on cfDNA yield and integrity and performance of the Ion PGM, Proton, and MiSeq NGS platforms. cfDNA from 31 patients with diverse advanced cancers and known tumor mutation status was deep sequenced using targeted hotspot panels. Forty-five of 52 expected mutations and two additional mutations (KRAS p.Q61H and EZH2 p.Y646F) were detected in plasma through a custom bioinformatics pipeline. We observed comparable cfDNA concentration/integrity between collection tubes within 16 hours of plasma separation and equal analytical performance among NGS platforms, with 1% detection sensitivity for cfDNA genotyping.


Subject(s)
Cell-Free Nucleic Acids/genetics , High-Throughput Nucleotide Sequencing/methods , Neoplasms/genetics , Adult , Aged , Aged, 80 and over , Biomarkers, Tumor/blood , Biomarkers, Tumor/genetics , Cell-Free Nucleic Acids/blood , Cohort Studies , DNA Mutational Analysis/methods , Female , Genomics/methods , Genotype , Humans , Male , Middle Aged , Mutation , Neoplasms/blood
13.
Mod Pathol ; 30(4): 499-508, 2017 04.
Article in English | MEDLINE | ID: mdl-28084342

ABSTRACT

Minimally invasive procedures, such as fine needle aspiration and core needle biopsy, are commonly used for the diagnosis in solid organ malignancies. In the era of targeted therapy, it is crucial for molecular testing to be performed on these limited volume specimens. Although several recent studies have demonstrated the utility of small biopsy specimens for molecular testing, there remains debate as to whether core needle biopsy specimens are more reliable than fine needle aspiration for molecular studies. In this study, we reviewed concurrently acquired fine needle aspiration and core needle biopsy samples (n=24), and compared overall cellularity, tumor fraction, and the results of next-generation sequencing. All somatic mutations detected in core needle biopsy samples were also detected in fine needle aspiration samples. The estimated tumor fraction was significantly higher in fine needle aspiration smears than core needle biopsy samples (P=0.003), whereas the overall DNA yield from smears was significantly lower than that obtained from the core needle biopsy specimens (P=0.01). The normalized average amplicon coverage for the genes analyzed was significantly higher in cytology smears than paired core needle biopsy samples, with lower numbers of failed amplicons and higher overall mutation allelic frequencies seen in the former. We further evaluated 100 malignant fine needle aspiration and core needle biopsy samples, acquired concurrently, for overall cellularity and tumor fraction. Overall cellularity and tumor fraction of fine needle aspiration samples was significantly higher than concurrently acquired core needle biopsy samples (P<0.001). In conclusion, we show that fine needle aspiration samples frequently provide better cellularity, higher tumor fraction, and superior sequencing metrics than concurrently acquired core needle biopsy samples. Cytologic specimens, therefore, should be better integrated into routine molecular diagnostics workflow to maximize limited tissues for clinically relevant genomic testing.


Subject(s)
High-Throughput Nucleotide Sequencing , Neoplasms/genetics , Neoplasms/pathology , Biopsy, Fine-Needle , Biopsy, Large-Core Needle , Humans , Mutation
14.
Clin Lymphoma Myeloma Leuk ; 16(7): 395-403.e1, 2016 07.
Article in English | MEDLINE | ID: mdl-27268124

ABSTRACT

OBJECTIVES: Waldenstrom macroglobulinemia (WM) is a B-cell lymphoma characterized by the accumulation of lymphocytes and plasmacytic cells in the bone marrow and by excess production of immunoglobulin M in serum. WM has been closely linked with the MYD88(L265P) mutation. Whole genome sequencing has identified somatic mutations in the CXCR4 gene in ∼29% of WM cases with MYD88(L265P). CXCR4 mutations may interfere with treatment response to ibrutinib. The goal of this study was to design and validate a clinical assay to detect CXCR4 mutations. METHODS: Thirty-three low-grade B-cell lymphomas with plasmacytic differentiation (23 MYD88(L265P) and 10 MYD88(WT)) involving various samples types (fresh and formalin-fixed tissues) formed the study group. We designed and validated Sanger sequencing and pyrosequencing assays to detect mutations in CXCR4 in a Clinical Laboratory Improvement Amendments-approved clinical laboratory. RESULTS: We identified 8 cases with CXCR4 mutations, including 5 single nucleotide substitutions (3 resulting in p.S338* and 1 in p.R334*), and 3 insertion/deletions. Seven of 8 CXCR4 mutated cases were also MYD88(L265P) mutant. Among the single nucleotide substitutions, we identified a novel missense variant (p.L326P) and a previously reported variant (G335S) of uncertain clinical significance. CONCLUSIONS: We successfully validated a set of clinical assays to detect mutations in CXCR4 mutations in a clinical laboratory.


Subject(s)
Mutation , Receptors, CXCR4/genetics , Waldenstrom Macroglobulinemia/diagnosis , Waldenstrom Macroglobulinemia/genetics , Alleles , Amino Acid Substitution , Biomarkers , DNA Mutational Analysis , Genotype , Humans , Immunoglobulin M/blood , Immunophenotyping , Myeloid Differentiation Factor 88/genetics , Neoplasm Grading , Reproducibility of Results
15.
Am J Clin Pathol ; 145(2): 222-37, 2016 Feb.
Article in English | MEDLINE | ID: mdl-27124905

ABSTRACT

OBJECTIVES: Clinical laboratories are rapidly implementing next-generation sequencing (NGS) tests for mutation analysis, but there are few guidelines regarding sample quality for successful results. METHODS: We aimed to establish tissue quality parameters for successful NGS in solid tumors and to improve NGS performance. RESULTS: Analysis of 614 clinical cases tested in 2013 using a 50-gene hotspot mutation panel identified the major cause for unsuccessful NGS analysis was DNA less than 10 ng (91%, 67/74) associated with extremely small and low cellularity samples. High success rates were associated with resection procedures (333/342, 97%) and biopsied tumor larger than 10 mm(2) (77/77, 100%). NGS can be successfully performed on bone specimens processed with formic acid-based decalcification procedures (8/11, 73%). Tumor type and paraffin block age did not affect success. We demonstrated that NGS can be carried out on samples with less than 10 ng DNA. Analysis of 408 cases tested in 2014 using an optimized workflow showed improved NGS success rates from 88% to 95% (387/408) with pronounced improvement among tiny (<10 mm(2)) samples (from 76% to 94%) as well as cytology samples (from 58% to 87%). CONCLUSIONS: Identifying preanalytical tissue factors allows us to improve NGS performance and to successfully test tumors obtained from minimally invasive procedures.


Subject(s)
Biomarkers, Tumor/genetics , DNA, Neoplasm/analysis , High-Throughput Nucleotide Sequencing , Neoplasms/diagnosis , Specimen Handling , DNA Mutational Analysis , DNA, Neoplasm/isolation & purification , Humans , Mutation , Neoplasms/genetics , Paraffin Embedding , Sequence Analysis, DNA , Tissue Fixation , Workflow
16.
Am J Clin Pathol ; 144(5): 746-55, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26486739

ABSTRACT

OBJECTIVES: To develop a polymerase chain reaction (PCR)-based approach to detect CALR mutations in myeloproliferative neoplasms (MPNs) in a clinical laboratory. METHODS: DNA was extracted from bone marrow aspirate samples of 67 JAK2 wild-type MPNs (22 with matched peripheral blood), 54 cases of unclassifiable myelodysplastic syndrome/MPN, and 16 cases of atypical chronic myeloid leukemia. We used genomic DNA to detect somatic mutations in exon 9 of CALR and PCR with fluorescently labeled and M13-tagged primers and subjected the products to capillary electrophoresis (CE) followed by Sanger sequencing. Detailed assay performance characteristics were established. RESULTS: We identified CALR mutations in 19 (28.4%) of 67 JAK2-negative MPNs, including 14 type I (52-base pair [bp] deletion), four type II (5-bp insertions), and one type III (18-bp deletion). All mutations were confirmed by Sanger sequencing. Sensitivity studies showed 2.5% and 5% mutation detection levels by CE and Sanger sequencing, respectively, with high reproducibility. CONCLUSIONS: This assay allows for rapid, convenient screening for CALR mutations in MPNs, thereby reducing the number of cases that require assessment by Sanger sequencing, reducing labor and improving turnaround time.


Subject(s)
Bone Marrow Neoplasms/diagnosis , DNA Mutational Analysis/methods , Genotype , Myeloproliferative Disorders/diagnosis , Bone Marrow Neoplasms/genetics , Calreticulin/genetics , Cell Line, Tumor , Humans , Janus Kinase 2/genetics , Mutation , Myeloproliferative Disorders/genetics , Reproducibility of Results
17.
Cancer Cytopathol ; 123(11): 659-68, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26230354

ABSTRACT

BACKGROUND: The use of cytology specimens for next-generation sequencing (NGS) is particularly challenging because of the unconventional substrate of smears and the often limited sample volume. An analysis of factors affecting NGS testing in cytologic samples may help to increase the frequency of successful testing. METHODS: This study reviewed variables associated with all in-house cytology cases (n = 207) that were analyzed by NGS with the Ion Torrent platform during a 10-month interval. A statistical analysis was performed to measure the effects of the DNA input threshold, specimen preparation, slide type, tumor fraction, DNA yield, and cytopathologist bias. RESULTS: One hundred sixty-four of 207 cases (79%) were successfully sequenced by NGS; 43 (21%) failed because of either a low DNA yield or a template/library preparation failure. The median estimated tumor fraction and DNA concentration for the successfully sequenced cases were 70% and 2.5 ng/µL, respectively, whereas they were 60% and 0.2 ng/µL, respectively, for NGS failures. Cell block sections were tested in 91 cases, and smears were used in 116 cases. NGS success positively correlated with the DNA yield but not the tumor fraction. Cell block preparations showed a higher success rate than smears. Frosted-tip slides yielded significantly more DNA than fully frosted slides. Lowering the input DNA concentration below the manufacturer's recommended threshold of 10 ng (>0.85 ng/µL) resulted in a marked increase in the NGS success rate from 58.6% to 89.8%. CONCLUSIONS: The failure of NGS with cytology samples is usually a result of suboptimal DNA due to multiple pre-analytical factors. Knowledge of these factors will allow better selection of cytology material for mutational analysis.


Subject(s)
High-Throughput Nucleotide Sequencing/methods , Neoplasms/genetics , Neoplasms/pathology , Sequence Analysis, DNA/methods , Biopsy, Needle , Cytodiagnosis/methods , Databases, Factual , Female , Humans , Immunohistochemistry , Male , Risk Factors , Sampling Studies , Sensitivity and Specificity , Tissue Embedding
19.
Hum Pathol ; 45(10): 1995-2005, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25128227

ABSTRACT

Anaplastic large cell lymphomas (ALCL) are tumors of T/null-cell lineage characterized by uniform CD30 expression. The 2008 World Health Organization classification subdivided ALCLs into 2 groups: anaplastic lymphoma kinase (ALK)-positive (established entity) and ALK-negative (proposed new entity) ALCL. The genetic basis for the pathogenesis of newly categorized ALK- ALCL is poorly understood. In this study, we used microRNA microarray analysis to identify differentially expressed microRNAs in ALK+ and ALK- ALCL. ALK- ALCL showed significantly higher expression of miR-155 (0.888 ± 0.228) compared with ALK+ ALCL (0.0565 ± 0.009) on microarray and by quantitative real-time polymerase chain reaction in ALK- ALCL compared with ALK+ ALCL (P < .05) with a strong correlation between the 2 platforms (R = 0.9, P < .0003). A novel in situ hybridization method allows direct visualization of expression patterns and relative quantitation of miR-155 (mean score, 2.3 versus 1.3; P = .01) for the first time in tissue sections of ALCL. Among computationally predicted targets of miR-155, we identified ZNF652 (r = -0.57, P = .05), BACH1 (r = 0.88, P = .02), RBAK (r = 0.81, P = .05), TRIM32 (r = 0.92, P = .01), E2F2 (r = 0.81, P = .05), and TP53INP1 (r = -0.31, P = .03) as genes whose expression by quantitative real-time polymerase chain reaction correlated significantly with the level of miR-155 in ALCL tumor tissue.


Subject(s)
Gene Expression Regulation, Neoplastic/genetics , Lymphoma, Large-Cell, Anaplastic/genetics , MicroRNAs/genetics , Adolescent , Adult , Anaplastic Lymphoma Kinase , Female , Humans , In Situ Hybridization , Lymphoma, Large-Cell, Anaplastic/enzymology , Male , Middle Aged , Oligonucleotide Array Sequence Analysis , Real-Time Polymerase Chain Reaction , Receptor Protein-Tyrosine Kinases/biosynthesis , Reverse Transcriptase Polymerase Chain Reaction , Young Adult
20.
Virchows Arch ; 465(3): 339-50, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25031014

ABSTRACT

Cutaneous carcinosarcoma (CCS) is an extraordinarily rare neoplasm with a biphasic morphological pattern exhibiting both epithelial and sarcomatoid components. Although its histogenesis and biological aspects remain poorly understood, previous studies have postulated that this tumor may arise from single cancer stem cells which subsequently differentiate into distinct tumor lineages. In this study, we explored a wide array of mutational hot spot regions, through high-depth next-generation sequencing of 47 cancer-associated genes in order to assess the mutational landscape of these tumors and investigate whether the epithelial and mesenchymal components shared the same genetic signatures. Results from this study confirm that despite their striking phenotypic differences, both elements of this infrequent tumor indeed share a common clonal origin. Additionally, CCS appears to embrace a heterogeneous spectrum with specific underlying molecular signatures correlating with the defining epithelial morphotype, with those carcinosarcomas exhibiting a squamous cell carcinoma epithelial component exhibiting diverse point mutations and deletions in the TP53 gene, and those with a basal cell carcinoma morphotype revealing a more complex mutational landscape involving several genes. Also, the fact that our findings involve several targetable gene pathways suggests that the underlying molecular events driving the pathogenesis of CCS may represent future potential targets for personalized therapies.


Subject(s)
Carcinosarcoma/genetics , Genome, Human , Mutation , Skin Neoplasms/genetics , Aged , Aged, 80 and over , Carcinosarcoma/pathology , Epithelial-Mesenchymal Transition , Female , Humans , Male , Middle Aged , Skin Neoplasms/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...