Anal Chem ; 89(1): 807-812, 2017 01 03.
Article in English | MEDLINE | ID: mdl-28105847

ABSTRACT

A compact ultrahigh-pressure nanoflow liquid chromatograph (LC) was developed with the purpose in mind of creating a portable system that could be easily moved to various testing locations or placed in close proximity to other instruments for optimal coupling, such as with mass spectrometry (MS). The system utilized innovative nanoflow pumps integrated with a very low volume stop-flow injector and mixing tee. The system weighed only 5.9 kg (13 lbs) or 4.5 kg (10 lbs) without a controller and could hold up to 1100 bar (16000 psi) of pressure. The total volume pump capacity was 60 µL. In this study, the sample injection volume was determined by either a 60 nL internal sample groove machined in a high-pressure valve rotor or by a 1 µL external sample loop, although other sample grooves or loops could be selected. The gradient dwell volume was approximately 640 nL, which allowed significant reduction in sample analysis time. Gradient performance was evaluated by determining the gradient step accuracy. A low RSD (0.6%, n = 4) was obtained for day-to-day experiments. Linear gradient reproducibility was evaluated by separating a three-component polycyclic aromatic hydrocarbon mixture on a commercial 150 µm inner diameter capillary column packed with 1.7 µm particles. Good retention-time reproducibility (RSD < 0.17%) demonstrated that the pumping system could successfully generate ultrahigh pressures for use in capillary LC. The system was successfully coupled to an LTQ Orbitrap MS in a simple and efficient way; LC-MS of a trypsin-digested bovine serum albumin (BSA) sample provided narrow peaks, short dwell time, and good peptide coverage.


Subject(s)
Nanotechnology , Serum Albumin, Bovine/analysis , Animals , Cattle , Chromatography, High Pressure Liquid , Mass Spectrometry , Pressure , Spectrophotometry, Ultraviolet
2.
Anal Chem ; 87(20): 10457-61, 2015 Oct 20.
Article in English | MEDLINE | ID: mdl-26378495

ABSTRACT

In this work, a novel splitless nanoflow gradient generator integrated with a stop-flow injector was developed and evaluated using an on-column UV-absorption detector. The gradient pumping system consisted of two nanoflow pumps controlled by micro stepper motors, a mixer connected to a serpentine tube, and a high-pressure valve. The gradient system weighed only 4 kg (9 lbs) and could generate up to 55 MPa (8000 psi) pressure. The system could operate using a 24 V DC battery and required 1.2 A for operation. The total volume capacity of the pump was 74 µL, and a sample volume of 60 nL could be injected. The system provided accurate nanoflow rates as low as 10 nL/min without employing a splitter, making it ideal for capillary column use. The gradient dwell volume was calculated to be 1.3 µL, which created a delay of approximately 4 min with a typical flow rate of 350 nL/min. Gradient performance was evaluated for gradient step accuracy, and excellent reproducibility was obtained in day-to-day experiments (RSD < 1.2%, n = 4). Linear gradient reproducibility was tested by separating a three-component pesticide mixture on a poly(ethylene glycol) diacrylate (PEGDA) monolithic column. The retention time reproducibility was very good in run-to-run experiments (RSD < 1.42%, n = 4). Finally, excellent separation of five phenols was demonstrated using the nanoflow gradient system.


Subject(s)
Chromatography, Liquid/instrumentation , Nanotechnology/instrumentation , Spectrophotometry, Ultraviolet/instrumentation