Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Europace ; 20(suppl_3): iii36-iii44, 2018 Nov 01.
Article in English | MEDLINE | ID: mdl-30476059

ABSTRACT

AIMS: Chronic left atrial enlargement (LAE) increases the risk of atrial fibrillation. Electrocardiogram (ECG) criteria might provide a means to diagnose LAE and identify patients at risk; however, current criteria perform poorly. We seek to characterize the potentially differential effects of atrial dilation vs. hypertrophy on the ECG P-wave. METHODS AND RESULTS: We predict effects on the P-wave of (i) left atrial dilation (LAD), i.e. an increase of LA cavity volume without an increase in myocardial volume, (ii) left atrial concentric hypertrophy (LACH), i.e. a thickened myocardial wall, and (iii) a combination of the two. We performed a computational study in a cohort of 72 anatomical variants, derived from four human atrial anatomies. To model LAD, pressure was applied to the LA endocardium increasing cavity volume by up to 100%. For LACH, the LA wall was thickened by up to 3.3 mm. P-waves were derived by simulating atrial excitation propagation and computing the body surface ECG. The sensitivity regarding changes beyond purely anatomical effects was analysed by altering conduction velocity by 25% in 96 additional model variants. Left atrial dilation prolonged P-wave duration (PWd) in two of four subjects; in one subject a shortening, and in the other a variable change were seen. Left atrial concentric hypertrophy, in contrast, consistently increased P-wave terminal force in lead V1 (PTF-V1) in all subjects through an enlarged amplitude while PWd was unaffected. Combined hypertrophy and dilation generally enhanced the effect of hypertrophy on PTF-V1. CONCLUSION: Isolated LAD has moderate effects on the currently used P-wave criteria, explaining the limited utility of PWd and PTF-V1 in detecting LAE in clinical practice. In contrast, PTF-V1 may be a more sensitive indicator of LA myocardial hypertrophy.


Subject(s)
Action Potentials , Atrial Fibrillation/diagnosis , Atrial Function, Left , Atrial Remodeling , Cardiomegaly/diagnosis , Electrocardiography , Heart Atria/physiopathology , Heart Rate , Atrial Fibrillation/etiology , Atrial Fibrillation/physiopathology , Cardiomegaly/complications , Cardiomegaly/physiopathology , Computer Simulation , Diagnosis, Differential , Heart Atria/diagnostic imaging , Humans , Magnetic Resonance Imaging , Models, Cardiovascular , Predictive Value of Tests , Risk Factors , Time Factors
2.
Proc Math Phys Eng Sci ; 471(2184): 20150641, 2015 Dec 08.
Article in English | MEDLINE | ID: mdl-26807042

ABSTRACT

Models of cardiac mechanics are increasingly used to investigate cardiac physiology. These models are characterized by a high level of complexity, including the particular anisotropic material properties of biological tissue and the actively contracting material. A large number of independent simulation codes have been developed, but a consistent way of verifying the accuracy and replicability of simulations is lacking. To aid in the verification of current and future cardiac mechanics solvers, this study provides three benchmark problems for cardiac mechanics. These benchmark problems test the ability to accurately simulate pressure-type forces that depend on the deformed objects geometry, anisotropic and spatially varying material properties similar to those seen in the left ventricle and active contractile forces. The benchmark was solved by 11 different groups to generate consensus solutions, with typical differences in higher-resolution solutions at approximately 0.5%, and consistent results between linear, quadratic and cubic finite elements as well as different approaches to simulating incompressible materials. Online tools and solutions are made available to allow these tests to be effectively used in verification of future cardiac mechanics software.

SELECTION OF CITATIONS
SEARCH DETAIL
...