Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
2.
Ground Water ; 60(1): 125-136, 2022 01.
Article in English | MEDLINE | ID: mdl-34448195

ABSTRACT

Fiber-optic (FO) technology is being used increasingly for measurement methods in a variety of environmental applications. However, FO pressure transducers are rarely used in hydrogeological applications. We review the current state of Fabry-Pérot interferometry-based FO pressure transducers, including their advantages and limitations, as another option for high-resolution pressure- or head-change measurements in conventional or advanced aquifer testing. Resolution and precision specifications of FO transducers meet or exceed commonly used non-FO pressure transducers. Due to their design, FO transducers can be used in small-diameter (inner diameter ≥1/4 inch) and continuous multichannel tubing (CMT), sampling points, multilevel packer systems, and Direct Push-based in situ installations and testing. The small diameter of FO transducers provides logistical advantages-especially for tests with monitoring at many zones in a number of wells and/or CMTs (e.g., no reels, placement just below water level in access tubes vs. within isolated zones, reduced weight and volume, small footprint at single point of data acquisition). Principal limitations are small measurement drift that may become evident for tests longer than a few hours, and higher-than-average cost. We present field examples of FO transducer performance in short-term tests with high consistency of acquired data and higher resolution (i.e., capturing significant hydrologic information) compared with commonly used non-FO transducers. Given the above, including advantageous logistical features, FO transducers can open new experimental possibilities in areas of high-resolution three-dimensional (3D) heterogeneity (flow and transport, remediation, critical zones); 3D fracture networks and fundamental hydromechanical behavior; complex 3D flow and leak detection (mines, dams, repositories, geothermal systems).


Subject(s)
Groundwater , Equipment Design , Fiber Optic Technology , Transducers
3.
Ground Water ; 58(2): 238-257, 2020 03.
Article in English | MEDLINE | ID: mdl-31187873

ABSTRACT

We present the first demonstration of hydraulic tomography (HT) to estimate the three-dimensional (3D) hydraulic conductivity (K) distribution of a fractured aquifer at high-resolution field scale (HRFS), including the fracture network and connectivity through it. We invert drawdown data collected from packer-isolated borehole intervals during 42 pumping tests in a wellfield at the former Naval Air Warfare Center, West Trenton, New Jersey, in the Newark Basin. Five additional tests were reserved for a quality check of HT results. We used an equivalent porous medium forward model and geostatistical inversion to estimate 3D K at high resolution (K blocks <1 m3 ), using no strict assumptions about K variability or fracture statistics. The resulting 3D K estimate ranges from approximately 0.1 (highest-K fractures) to approximately 10-13  m/s (unfractured mudstone). Important estimated features include: (1) a highly fractured zone (HFZ) consisting of a sequence of high-K bedding-plane fractures; (2) a low-K zone that disrupts the HFZ; (3) several secondary fractures of limited extent; and (4) regions of very low-K rock matrix. The 3D K estimate explains complex drawdown behavior observed in the field. Drawdown tracing and particle tracking simulations reveal a 3D fracture network within the estimated K distribution, and connectivity routes through the network. Model fit is best in the shallower part of the wellfield, with high density of observations and tests. The capabilities of HT demonstrated for 3D fractured aquifer characterization at HRFS may support improved in situ remediation for contaminant source zones, and applications in mining, repository assessment, or geotechnical engineering.


Subject(s)
Groundwater , Models, Theoretical , New Jersey , Tomography , Tomography, X-Ray Computed , Water Movements
4.
Ground Water ; 58(5): 710-722, 2020 09.
Article in English | MEDLINE | ID: mdl-31691263

ABSTRACT

Modeling and laboratory experiments have demonstrated the ability of oscillatory hydraulic tomography (OHT) to characterize heterogeneity in aquifer hydraulic properties. In OHT, a location is stressed via periodic pumping/injection at a set frequency, and the resulting head signal is measured at a number of monitoring locations. The source of oscillations is repeatedly moved, allowing tomographic imaging of aquifer properties. Changing the period of oscillation also results in observations with additional information. In theory, OHT is comparable to other hydraulic tomography methods in that distributed pressure change measurements provide characterization information. In practice, OHT has several benefits including: (1) little to no water injected into or extracted from the aquifer; and (2) an observational signal at a set period that can be easily extracted in the presence of noise. We report the first field application of OHT, carried out at the Boise Hydrogeophysical Research Site (BHRS) using an oscillating signal generator with a very small cycling volume of <2 L, and a period range of 5 to 70 s. For these tests, signals were detected at distances of over 15 m. After processing to extract periodic signal properties, we perform tomography using a frequency-domain numerical model for groundwater flow. In comparing results against prior characterization results from the BHRS, we find moderate to strong positive correlations between K profiles estimated via different methods at multiple wells, with moderate overall correlation between estimated three-dimensional (3D) K volumes.


Subject(s)
Groundwater , Models, Theoretical , Tomography , Water Movements , Water Wells
5.
Ground Water ; 54(2): 171-85, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26096272

ABSTRACT

Hydraulic tomography is an emerging field and modeling method that provides a continuous hydraulic conductivity (K) distribution for an investigated region. Characterization approaches that rely on interpolation between one-dimensional (1D) profiles have limited ability to accurately identify high-K channels, juxtapositions of lenses with high K contrast, and breaches in layers or channels between such profiles. However, locating these features is especially important for groundwater flow and transport modeling, and for design and operation of in situ remediation in complex hydrogeologic environments. We use transient hydraulic tomography to estimate 3D K in a volume of 15-m diameter by 20-m saturated thickness in a highly heterogeneous unconfined alluvial (clay to sand-and-gravel) aquifer with a K range of approximately seven orders of magnitude at an active industrial site in Assemini, Sardinia, Italy. A modified Levenberg-Marquardt algorithm was used for geostatistical inversion to deal with the nonlinear nature of the highly heterogeneous system. The imaging results are validated with pumping tests not used in the tomographic inversion. These tests were conducted from three of five clusters of continuous multichannel tubing (CMTs) installed for observation in the tomographic testing. Locations of high-K continuity and discontinuity, juxtaposition of very high-K and very low-K lenses, and low-K "plugs" are evident in regions of the investigated volume where they likely would not have been identified with interpolation from 1D profiles at the positions of the pumping well and five CMT clusters. Quality assessment methods identified a suspect high-K feature between the tested volume and a lateral boundary of the model.


Subject(s)
Environmental Monitoring/methods , Groundwater/analysis , Tomography/methods , Water Movements , Hydrology/methods , Italy , Models, Theoretical , Tomography/instrumentation
6.
Ground Water ; 53(6): 896-907, 2015.
Article in English | MEDLINE | ID: mdl-25535805

ABSTRACT

Oscillatory pumping tests-in which flow is varied in a periodic fashion-provide a method for understanding aquifer heterogeneity that is complementary to strategies such as slug testing and constant-rate pumping tests. During oscillatory testing, pressure data collected at non-pumping wells can be processed to extract metrics, such as signal amplitude and phase lag, from a time series. These metrics are robust against common sensor problems (including drift and noise) and have been shown to provide information about aquifer heterogeneity. Field implementations of oscillatory pumping tests for characterization, however, are not common and thus there are few guidelines for their design and implementation. Here, we use available analytical solutions from the literature to develop design guidelines for oscillatory pumping tests, while considering practical field constraints. We present two key analytical results for design and analysis of oscillatory pumping tests. First, we provide methods for choosing testing frequencies and flow rates which maximize the signal amplitude that can be expected at a distance from an oscillating pumping well, given design constraints such as maximum/minimum oscillator frequency and maximum volume cycled. Preliminary data from field testing helps to validate the methodology. Second, we develop a semi-analytical method for computing the sensitivity of oscillatory signals to spatially distributed aquifer flow parameters. This method can be quickly applied to understand the "sensed" extent of an aquifer at a given testing frequency. Both results can be applied given only bulk aquifer parameter estimates, and can help to optimize design of oscillatory pumping test campaigns.


Subject(s)
Groundwater/analysis , Models, Theoretical , Water Wells , Hydrology/methods , Pressure , Water Supply
7.
J Contam Hydrol ; 108(3-4): 77-88, 2009 Sep 01.
Article in English | MEDLINE | ID: mdl-19683833

ABSTRACT

It is widely recognized that groundwater flow and solute transport in natural media are largely controlled by heterogeneities. In the last three decades, many studies have examined the effects of heterogeneous hydraulic conductivity fields on flow and transport processes, but there has been much less attention to the influence of heterogeneous porosity fields. In this study, we use porosity and particle size measurements from boreholes at the Boise Hydrogeophysical Research Site (BHRS) to evaluate the importance of characterizing the spatial structure of porosity and grain size data for solute transport modeling. Then we develop synthetic hydraulic conductivity fields based on relatively simple measurements of porosity from borehole logs and grain size distributions from core samples to examine and compare the characteristics of tracer transport through these fields with and without inclusion of porosity heterogeneity. In particular, we develop horizontal 2D realizations based on data from one of the less heterogeneous units at the BHRS to examine effects where spatial variations in hydraulic parameters are not large. The results indicate that the distributions of porosity and the derived hydraulic conductivity in the study unit resemble fractal normal and lognormal fields respectively. We numerically simulate solute transport in stochastic fields and find that spatial variations in porosity have significant effects on the spread of an injected tracer plume including a significant delay in simulated tracer concentration histories.


Subject(s)
Porosity , Water Movements , Environmental Monitoring
8.
Ground Water ; 47(4): 515-25, 2009.
Article in English | MEDLINE | ID: mdl-19341370

ABSTRACT

This paper describes a combined field, laboratory, and numerical study of electromagnetic borehole flowmeter measurements acquired without the use of a packer or skirt to block bypass flow around the flowmeter. The most significant finding is that inflow through the wellbore screen changes the ratio of flow through the flowmeter to wellbore flow. Experiments reveal up to a factor of two differences in this ratio for conditions with and without inflow through the wellbore screen. Standard practice is to assume the ratio is constant. A numerical model has been developed to simulate the effect of inflow on the flowmeter. The model is formulated using momentum conservation within the borehole and around the flowmeter. The model is embedded in the MODFLOW-2000 ground water flow code.


Subject(s)
Environmental Monitoring/methods , Water Movements
SELECTION OF CITATIONS