Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 18(11): e0293984, 2023.
Article in English | MEDLINE | ID: mdl-37963155

ABSTRACT

OBJECTIVE: We aim to assess the accuracy and effectiveness of the HemoCue 301, a point-of-care (POC) device for measuring hemoglobin levels, and detecting anemia among individuals living in Tumbes, a rural, underserved area in Northern Peru. METHODS: Baseline analysis of a clinical trial aimed at assessing the effect of multi-fortified bread (NCT05103709). Adult women with capillary blood HemoCue 301 readings below 12 g/dL were recruited in coastal city of Tumbes, Peru. A total of 306 women took part of the study, venous blood samples were taken and analyzed with an automated hematology analyzer. Serum samples were used to measure ferritin, serum iron and C reactive protein. RESULTS: Capillary blood measured by the Hemocue 301 has a bias of 0.36 ± 0.93 g/dL respect to the automated Hb. More than 50% of women with normal ferritin values were classified as anemics according to the HemoCue 301. Automated Hb cut-off of 10.8 g/dL [AUC 0.82 (0.77-0.88)] had a specificity of 0.817 and a sensitivity 0.711 while with the HemoCue 301 cut-off of 11.1 g/dL [AUC 0.71 (0.62-0.79)] had a specificity of 0.697 and a sensitivity 0.688. The performance of the automated Hb cut-off was significantly better than the HemoCue (p<0.001). CONCLUSION: Caution must be taken when using POC devices, especially with values around the threshold. Cut-off values found in our study could be used as surrogate means when no confirmatory tests are available. Clinical outcomes should be prioritized when diagnosing iron deficiency anemia in women of reproductive age to ensure proper diagnosis.


Subject(s)
Anemia , Hematology , Adult , Humans , Female , Peru/epidemiology , Hemoglobins/analysis , Anemia/diagnosis , Hemoglobinometry , Ferritins
2.
Am J Trop Med Hyg ; 97(6): 1830-1832, 2017 12.
Article in English | MEDLINE | ID: mdl-29016332

ABSTRACT

The lentil lectin glycoprotein enzyme-linked immunoelectrotransfer blot (LLGP EITB, reported sensitivity 99% and specificity 100%) is used as a serologic marker of exposure to Taenia solium in pigs. However, only a limited number of parasites have been evaluated for cross reactivity. Pigs may host other related cestode infections, including Taenia hydatigena, which have not been formally evaluated for cross-reactions. We investigated a corral in Tumbes, Peru, a region where a cysticercosis elimination demonstration project was completed in 2012. In this corral, 14/19 (73.7%) 6-8-week-old piglets were reactive to GP50 on LLGP EITB, and all had circulating Taenia sp. antigens. From eight necropsied piglets; four were infected with T. hydatigena metacestodes whereas none had evidence of T. solium infection. Two resident dogs were subsequently confirmed to have T. hydatigena taeniasis. These results suggest GP50 cross-reactivity in T. hydatigena-infected pigs, although controlled experimental infection is needed to confirm this hypothesis.


Subject(s)
Antigens, Helminth/blood , Cysticercosis/diagnosis , Cysticercosis/veterinary , Nerve Tissue Proteins/blood , Taenia/isolation & purification , Animals , Antibodies, Helminth/blood , Biomarkers/blood , Cross Reactions , Cysticercosis/blood , Dogs/parasitology , Host-Parasite Interactions , Peru , Sensitivity and Specificity , Swine/parasitology , Swine Diseases/blood , Swine Diseases/diagnosis , Swine Diseases/parasitology , Taenia/classification
SELECTION OF CITATIONS
SEARCH DETAIL
...