1.
J Arthroplasty ; 34(6): 1139-1142, 2019 06.
Article in English | MEDLINE | ID: mdl-30885407

ABSTRACT

BACKGROUND: Interest in direct anterior approach (DAA) has increased over the last decade. In our previously published study comparing DAA to posterolateral approach (PA), early 3-month benefits were noted in terms of pain and function. There was no difference noted at 6 or 12 months. This study reports average 5-year follow-up of our original study. METHODS: Originally there were 43 DAA patients and 44 PA patients. At an average 5-year follow-up, patients were evaluated clinically with a University of California at Los Angeles activity score, Harris hip score, and Hip Disability and Osteoarthritis Outcome Score Jr Survivorship analysis was calculated. Radiographs were evaluated for loosening and evidence of radiolucent lines. RESULTS: There were 2 deaths 1 in each group, neither was related to the implant or procedure. Four patients were lost to follow-up: 2 in the DAA group and 2 in the PA group. There was no statistical difference between surgical approaches in terms of Harris hip score, University of California at Los Angeles activity score, and Hip Disability and Osteoarthritis Outcome Score Jr. The 7-year survivorship was not significantly different. There were no loose implants at average 5-year follow-up. CONCLUSION: Both DAA and PA yield good results at an average 5-year follow-up in terms of survivorship, function, rate of complications, and radiographic analysis.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Prosthesis Design , Adult , Aged , Arthroplasty, Replacement, Hip/instrumentation , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Patient Safety , Prospective Studies , Severity of Illness Index , Treatment Outcome
2.
Knee ; 23(3): 545-8, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26947462

ABSTRACT

BACKGROUND: Bone loss in revision total knee arthroplasty is common. Various reconstruction options are available. The purpose of our study is to report on one such reconstruction option, titanium metaphyseal sleeves. METHODS: We describe a series of 45 patients (46 knees) who underwent revision total knee arthroplasty and were treated with a porous metaphyseal sleeve between August 2000 and September 2009 at two centers. Patients were followed for a minimum of four years, and at final follow-up, 40 patients (40 knees) were available for review. Patients were evaluated using The Knee Society's Knee Scoring System at each follow-up. Radiographs (standing anteroposterior, lateral, and sunrise views) were taken at six weeks, three months, and final evaluations. RESULTS: Mean Knee Society Scores increased from 36 (range 10 to 69) pre-operatively to 90 (range 38 to 100) at final follow-up. Mean alignment on final radiographic evaluation was 5° (range 3° to 8° valgus). Mean pre-operative alignment was 6° (range 15° varus to 18° valgus). Mean range of motion was 125° (range 80° to 140°) pre-operatively and 115° (range 95° to 130°) postoperatively. One device failed to achieve ingrowth and was revised at two years. All other knees were radiographically stable and ingrown. CONCLUSIONS: Metaphyseal sleeves provide an alternative for bone loss reconstruction in revision total knee arthroplasty. LEVEL OF EVIDENCE: III.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Bone Resorption/surgery , Knee Joint/surgery , Knee Prosthesis , Tibia/surgery , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/adverse effects , Bone Resorption/etiology , Female , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Reoperation
3.
J Arthroplasty ; 28(9): 1634-8, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23523485

ABSTRACT

Benefits of a direct anterior approach (DAA) versus a posterior-lateral (PA) approach to THA were assessed in a single-surgeon, IRB-approved, prospective, randomized clinical study. Subjects (43 DAA and 44 PA) were evaluated at 6 weeks, and 3, 6 and 12 months. The primary end point was ability to climb stairs normally and walk unlimited at each time point. Secondary end points included assessment by several outcome instruments. DAA subjects performed better during the immediate post-operative period; they had lower VAS pain scores on the first post-operative day, more subjects climbing stairs normally and walking unlimited at 6 weeks, and higher HOOS Symptoms scores at 3 months. There were no significant differences between groups at later time points. Findings confirm previous reports of benefits of DAA versus PA in early post-operative phases.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Aged , Female , Humans , Male , Middle Aged , Prospective Studies
4.
J Arthroplasty ; 27(6): 976-83.e1, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22425300

ABSTRACT

Large-diameter modular metal-on-metal (MOM) total hip arthroplasty (THA) may offer reduction in wear debris and improved stability. Four studies are summarized here that used a large-diameter modular MOM system. A total of 1076 THAs were performed. This article presents data from 779 of these THAs with minimum 2-year follow-up (mean, 4.2 years) or revision since index THA (21 hips, with 1 more pending). Overall survivorship at 2 years was 98.6%; at 5 years, it was 97.0%. Seven revisions for an adverse reaction to metallic debris (ARMED), and 1 additional pending revision for ARMED, showed marked variability in presenting symptoms and intraoperative and postoperative findings. Data show good clinical performance of the modular MOM system, but suggest that surgeons must be diligent in monitoring MOM THA patients and aggressive in diagnosing and revising patients with a potential ARMED.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/adverse effects , Metals/adverse effects , Osteoarthritis, Hip/surgery , Prosthesis Design , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Incidence , Male , Middle Aged , Prospective Studies , Prosthesis Failure , Radiography , Reoperation , Retrospective Studies , Risk Factors
5.
J Arthroplasty ; 26(8): 1273-1284.e1, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21723703

ABSTRACT

A total of 208 patients were enrolled in a multicenter, prospective randomized, institutional review board-approved study that compared preoperative surgical plan to postoperative 2-dimensional radiographic alignment measured by a blinded reviewer for primary total knee arthroplasty (TKA) implanted using computer-assisted surgery (CAS) compared with conventional TKA instrumentation. The results demonstrated a statistically significant improvement in the coronal tibial component alignment (P < .03) and failed to demonstrate a statistically significant improvement in the mechanical axis, femoral coronal/sagittal, and tibial sagittal alignment. Knee Society Score knee and function scores and 6-minute walk test were equivalent between the 2 treatment groups at all postoperative intervals. There was a statistically significant increase in the skin-skin time (P < .0001) and the time until first bone cut (P < .0001) for the CAS knees compared with those implanted with conventional instrumentation. The use of CAS in this randomized clinical trial conducted at high-volume centers did not offer a clinically meaningful improvement in postoperative alignment, clinical, functional, or safety outcomes compared with conventional TKA.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Bone Malalignment/diagnostic imaging , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Surgery, Computer-Assisted/methods , Adult , Aged , Arthroplasty, Replacement, Knee/adverse effects , Bone Malalignment/prevention & control , Female , Femur/diagnostic imaging , Humans , Knee Joint/physiology , Knee Prosthesis , Male , Middle Aged , Prospective Studies , Radiography , Range of Motion, Articular/physiology , Retrospective Studies , Severity of Illness Index , Single-Blind Method , Surgery, Computer-Assisted/adverse effects , Tibia/diagnostic imaging , Treatment Outcome , Walking/physiology
6.
Orthopedics ; 29(9 Suppl): S53-5, 2006 Sep.
Article in English | MEDLINE | ID: mdl-17002150

ABSTRACT

Aging boomers and younger patients requiring total knee arthroplasty demand and/or expect better function, improved durability, and a quicker recovery. In response to this demand, surgeons are modifying surgical techniques, and industry is examining implant design. One proposal is the gender-specific implant, but the development of separate systems for men and women may prove to be unnecessary.


Subject(s)
Knee Prosthesis , Sex Characteristics , Female , Humans , Male , Prosthesis Design