Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 182
Filter
1.
Cardiorenal Med ; 14(1): 202-214, 2024.
Article in English | MEDLINE | ID: mdl-38513622

ABSTRACT

INTRODUCTION: Chronic heart failure (HF) has high rates of mortality and hospitalization in patients with advanced chronic kidney disease (aCKD). However, randomized clinical trials have systematically excluded aCKD population. We have investigated current HF therapy in patients receiving clinical care in specialized aCKD units. METHODS: The Heart And Kidney Audit (HAKA) was a cross-sectional and retrospective real-world study including outpatients with aCKD and HF from 29 Spanish centers. The objective was to evaluate how the treatment of HF in patients with aCKD complied with the recommendations of the European Society of Cardiology Guidelines for the diagnosis and treatment of HF, especially regarding the foundational drugs: renin-angiotensin system inhibitors (RASi), angiotensin receptor blocker/neprilysin inhibitors (ARNI), beta-blockers (BBs), mineralocorticoid receptor antagonists (MRAs), and sodium-glucose cotransporter-2 inhibitors (SGLT2i). RESULTS: Among 5,012 aCKD patients, 532 (13%) had a diagnosis of HF. Of them, 20% had reduced ejection fraction (HFrEF), 13% mildly reduced EF (HFmrEF), and 67% preserved EF (HFpEF). Only 9.3% of patients with HFrEF were receiving quadruple therapy with RASi/ARNI, BB, MRA, and SGLT2i, but the majority were not on the maximum recommended doses. None of the patients with HFrEF and CKD G5 received quadruple therapy. Among HFmrEF patients, approximately half and two-thirds were receiving RASi and/or BB, respectively, while less than 15% received ARNI, MRA, or SGLT2i. Less than 10% of patients with HFpEF were receiving SGLT2i. CONCLUSIONS: Under real-world conditions, HF in aCKD patients is sub-optimally treated. Increased awareness of current guidelines and pragmatic trials specifically enrolling these patients represent unmet medical needs.


Subject(s)
Adrenergic beta-Antagonists , Angiotensin Receptor Antagonists , Heart Failure , Mineralocorticoid Receptor Antagonists , Renal Insufficiency, Chronic , Sodium-Glucose Transporter 2 Inhibitors , Stroke Volume , Humans , Heart Failure/complications , Heart Failure/drug therapy , Heart Failure/physiopathology , Retrospective Studies , Male , Female , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/physiopathology , Aged , Cross-Sectional Studies , Mineralocorticoid Receptor Antagonists/therapeutic use , Angiotensin Receptor Antagonists/therapeutic use , Adrenergic beta-Antagonists/therapeutic use , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use , Stroke Volume/physiology , Middle Aged , Spain/epidemiology , Guideline Adherence , Angiotensin-Converting Enzyme Inhibitors/therapeutic use , Aged, 80 and over
2.
Transplant Proc ; 56(2): 310-315, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38365514

ABSTRACT

Transplantation (KTx) is considered to be the best renal replacement therapy, and improving its outcomes remains a primary challenge. KTx ureteral stenting has been used to prevent urological complications, but there is no consensus on the timing of stent removal, and literature regarding routine ultrasonography after ureteric stent removal (RUSUS) to detect complications is lacking. Point-of-care ultrasound has been gaining drive in the medical community in recent years, including nephrologists. We aimed to define the incidence of urological complications diagnosed with RUSUS, if those findings changed patient's management and ultrasound utility. Contrary to previously published data, in our cohort RUSUS allowed a timely diagnosis and early treatment of urological complications, a key factor for successful transplantation. KTx point-of-care ultrasound is a cost-effective and reproducible test that provides relevant information to guide clinical decisions, seeming most efficient when performed approximately 2 weeks post ureteral stent removal. Interventional nephrologists can promptly perform these examinations, reducing waiting times and improving graft and patient's survival.


Subject(s)
Postoperative Complications , Ureter , Humans , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Ureter/diagnostic imaging , Ureter/surgery , Stents , Kidney , Ultrasonography
3.
J Ultrasound ; 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38413476

ABSTRACT

Page's kidney is a condition that occurs due to external renal compression, usually caused by a subcapsular haematoma, generating a renal compartmental syndrome with parenchymal damage and renal perfusion alteration. Classically associated with renal trauma, Page's kidney can also arise after invasive renal procedures, such as renal biopsies or percutaneous nephrostomies. Clinically, it can trigger hypertension due to activation of the renin-angiotensin system induced by hypoperfusion secondary to renal parenchymal compression and can also present with varying degrees of renal function impairment. Furthermore, severe acute renal failure may be found particularly in patients with solitary kidneys or renal transplants. We present two cases of Page's kidney after renal biopsy and their PoCUS ultrasound findings. We would like to highlight the reversed diastolic flow on Doppler ultrasound in this entity, a pattern we have found in all two cases.

4.
POCUS J ; 8(2): 132-135, 2023.
Article in English | MEDLINE | ID: mdl-38099172

ABSTRACT

Renal artery stenosis of the kidney allograft associated with kinking is not a frequent finding. As a correctable cause of graft dysfunction, it is important to diagnose it as soon as possible to avoid further graft damage and improve graft and patient survival. As pulsed wave Doppler ultrasound mapping of the graft's renal arteries is essential to diagnose possible alterations, point of care ultrasound (POCUS) is a highly useful tool for early diagnosis. We present a case in which nephrologists performed this examination promptly allowing a timely diagnosis and treatment plan.

5.
J Nephrol ; 35(9): 2451-2457, 2022 12.
Article in English | MEDLINE | ID: mdl-36131133

ABSTRACT

BACKGROUND: Peritoneal dialysis (PD) has multiple advantages over other dialysis modalities. As a home-based therapy, it allows patients to keep their autonomy, avoid frequent hospital visits and carry on with their usual lifestyle. However, as a self-care therapy, dependency has been traditionally considered a contraindication. However, assistance to perform PD (asPD) can be provided regardless of the patient's age and the duration of such help. This paper is aimed at reporting on assisted PD use in a Spanish Center, and is the first report on asPD from this country. METHODS: We retrospectively reviewed the electronic medical records of all patients consecutively treated with PD between May 1997 and December 2020 in our PD Unit. Assisted PD was defined as PD treatment requiring the help of another person. On the basis of the duration of dependency, we divided our cohort into: Group 1: Patients totally dependent at the start of PD treatment; Group 2: self-care patients that developed total dependency during follow up; Group 3: patients who needed short-term PD assistance. Group 4, consisting of 175 self-care PD, served as the control group. RESULTS: Seventy-three percent of patients who required asPD did so during their follow up, showing that an important proportion of patients may require some help even if they were autonomous at the beginning of PD. Even for short time periods, asPD should be an option, as up to 44% of autonomous PD patients became dependent for different reasons over time. Spouses were the most frequent caregivers and absence or loss of caregiver was a main reason for switching to hemodialysis. Fourteen percent of the patients received asPD as palliative care, with clinical symptoms and perceived well-being as the main treatment goals, with adequate results. The need for support and the quality of life were periodically discussed by patients, family members and hospital staff. CONCLUSION: Assisted PD is a safe option for dependent patients, young or elderly, and may result less expensive for our healthcare system, even when caregivers receive a financial incentive.


Subject(s)
Peritoneal Dialysis , Quality of Life , Humans , Aged , Retrospective Studies , Peritoneal Dialysis/adverse effects , Peritoneal Dialysis/methods , Renal Dialysis , Caregivers
6.
J Vasc Access ; : 11297298221122134, 2022 Sep 21.
Article in English | MEDLINE | ID: mdl-36131390

ABSTRACT

There are a significant number of mechanical complications related the peritoneal dialysis (PD) catheter and early diagnosis is key. Between them, the spontaneous extrusion of the catheter is quite uncommon but it should be included among the possible complications of the technique, given that it can be related to frequent situations in PD patients like abdominal wall issues, past immunosuppression or PD fluid leakage. In 25 years our Unit had three cases, probably related to peritoneal fluid leakage, exit site infection and past steroid treatment. Careful examination of abdominal wall preimplantation, adequate break-in period to allow maturation and early detection of exit site infection to start treatment in a timely fashion could help to prevent this rare complication. The complete extrusion of the catheter does not preclude from continuing PD treatment.

7.
Case Rep Nephrol Dial ; 11(3): 321-326, 2021.
Article in English | MEDLINE | ID: mdl-34950708

ABSTRACT

Although gastrointestinal symptoms are not uncommon in PD patients due to several causes, such as infusion volume with early satiety, constipation, or peritonitis, sometimes the differential diagnosis is more challenging for nephrologists. We present the case of a woman with end-stage renal disease due to autosomal dominant polycystic kidney disease on PD who presented with swollen legs and incoercible vomiting. After ruling out constipation and infection, an abdominal CT was done, revealing extrinsic compression of the intrahepatic inferior cava vein (ICV) and massive venous thrombosis from ICV to bilateral iliofemoral deep veins. In addition, CT also showed displacement and extrinsic compression of the stomach, pylorus, and duodenum due to an enlarged liver cyst. Percutaneous drainage and sclerosis of the cyst compressing the stomach was performed, anticoagulation was started, and the patient clinically improved with complete resolution of symptoms.

8.
J Int Med Res ; 49(9): 3000605211040764, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34590925

ABSTRACT

BACKGROUND: Percutaneous renal biopsy (PRB) is invasive, and bleeding-related complications are a concern. Desmopressin (DDAVP) is a selective type 2 vasopressin receptor-agonist also used for haemostasis. AIM: To evaluate the side effects of intravenous (IV) weight-adjusted desmopressin preceding PRB. METHODS: This was a retrospective study of renal biopsies performed by nephrologists from 2013 to 2017 in patients who received single-dose DDAVP pre-PRB. RESULTS: Of 482 PRBs, 65 (13.5%) received DDAVP (0.3 µg/kg); 55.4% of the PRBs were native kidneys. Desmopressin indications were altered platelet function analyser (PFA)-100 results (75.3% of the patients), urea >24.9 mmol/L (15.5%), antiplatelet drugs (6.1%) and thrombocytopaenia (3%). Of the 65 patients, 30.7% had minor asymptomatic complications, and 3 patients had major complications. Pre-PRB haemoglobin (Hb) <100 g/L was a risk factor for Hb decrease >10 g/L, and altered collagen-epinephrine (Col-Epi) time was a significant risk factor for overall complications. Mean sodium decrease was 0.6 ± 3 mmol/L. Hyponatraemia without neurological symptoms was diagnosed in two patients; no cardiovascular events occurred. CONCLUSION: Hyponatraemia after single-dose DDAVP is rare. A single IV dose of desmopressin adjusted to the patient's weight is safe as pre-PRB bleeding prophylaxis.


Subject(s)
Deamino Arginine Vasopressin , Hemostatics , Biopsy , Deamino Arginine Vasopressin/adverse effects , Hemorrhage/chemically induced , Hemorrhage/prevention & control , Humans , Retrospective Studies
9.
J Vasc Access ; 22(2): 319-321, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32339060

ABSTRACT

Jugular Tesio lines (TesioCaths; MedCOMP, Harleysville, PA, USA) are frequently used as permanent vascular accesses in haemodialysis patients. During the insertion procedure, arrhythmias are a relatively common complication, usually related to an excessively advanced catheter tip, without major consequences. We present two cases of life-threatening arrhythmias triggered by the Tesio catheter eccentric high-velocity jet of blood resolved after reposition of the catheter without further episodes, despite both lines being inserted under real-time ultrasound and fluoroscopic guidance. We believe dialysis lines should be checked for tip position even when long-standing to prevent relevant complications due to catheter sliding.


Subject(s)
Arrhythmias, Cardiac/etiology , Catheterization, Central Venous/adverse effects , Kidney Failure, Chronic/therapy , Renal Dialysis , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/therapy , Catheterization, Central Venous/instrumentation , Catheters, Indwelling , Central Venous Catheters , Female , Humans , Kidney Failure, Chronic/diagnosis , Male , Middle Aged , Risk Factors , Treatment Outcome
10.
J Vasc Access ; 22(2): 261-265, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32605474

ABSTRACT

BACKGROUND: Relapsing peritonitis due to the development of a biofilm in the catheter's lumen remains an important complication of peritoneal dialysis therapy that endangers technique continuity. Taurolidine catheter lock has proven efficient reducing infection rates in permanent hemodialysis catheters based on its biocidal activity and biofilm detachment effect. Efficacy evidence on its use in peritoneal dialysis catheters is lacking. METHODS: We retrospectively analyzed all relapsing peritonitis episodes from June 2018 until October 2019 in our center. Patients were identified and data were collected from our electronic renal registry and patient's records. RESULTS: Six patients were identified during the study period. Most patients (66.6%) were on automated peritoneal dialysis and the median duration of peritoneal dialysis before the episode of taurolidine was started was 43.66 ± 29.64 months. Mean taurolidine doses were 10 (range: 9-11) and 83.3% (five patients, with peritonitis caused by Pseudomonas aeruginosa, Staphylococcus aureus, Escherichia coli, and Corynebacterium propinquum) had a favorable response and microbial eradication without relapses after taurolidine treatment. Only one patient relapsed by the same organism (Corynebacterium amycolatum) due to non-adherence to the antibiotic treatment prescribed. None of the patients experienced any relevant adverse events, with only two out of six presenting mild transient abdominal discomfort. CONCLUSION: We believe that peritoneal catheter taurolidine lock could be considered in cases of relapsing or refractory peritonitis, as it could prevent catheter removal and permanent switch to hemodialysis in selected cases, although literature is scarce and further studies are needed.


Subject(s)
Anti-Infective Agents/therapeutic use , Catheter-Related Infections/prevention & control , Catheterization/instrumentation , Catheters, Indwelling , Peritoneal Dialysis/instrumentation , Peritonitis/prevention & control , Taurine/analogs & derivatives , Thiadiazines/therapeutic use , Adult , Aged , Aged, 80 and over , Anti-Infective Agents/adverse effects , Catheter-Related Infections/microbiology , Catheterization/adverse effects , Catheters, Indwelling/adverse effects , Female , Humans , Male , Middle Aged , Peritoneal Dialysis/adverse effects , Peritonitis/microbiology , Recurrence , Retrospective Studies , Risk Assessment , Risk Factors , Taurine/adverse effects , Taurine/therapeutic use , Thiadiazines/adverse effects , Time Factors , Treatment Outcome
11.
Clin Exp Nephrol ; 25(3): 289-296, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33184742

ABSTRACT

BACKGROUND: Within peritoneal dialysis (PD) complications, peritonitis remains a primary challenge for the long-term success of the technique. Proper technique training is essential, since it reduces peritonitis rates, but the adequacy of training has not been standardized. Furthermore, factors influencing training duration have not been well identified. METHODS: We retrospectively analyzed all consecutive training sessions of incident PD patients in our Unit from January 2001 to December 2018. RESULTS: Our analysis included 135 patients, 25.9% were diabetic and median Charlson index (CCI) was 4 (IQR 2-6). Above 13 sessions was chosen as the cut off between usual and prolonged training, as it was our cohort's 75th percentile: 23% (31) had an extended training duration as per our study definition and 77% (104) had a usual training duration. The number of training sessions required increased with age (Spearman Rho 0.404; p = 0.000001), diabetic status (p = 0.001), unemployment status (p = 0.046) and CCI (Spearman Rho 0.369; p = 0.00001). Neither gender, cohabitation status, scheduled PD start, education level nor referral origin, were significant factors impacting training duration. Requiring longer training (> 13 sessions) was a significant risk factor for higher peritonitis risk, but extended training was not related to a shorter technique survival. CONCLUSION: Number of PD training sessions depends on the patient's age and comorbidities, but is not related to social, educational or employment status. Prolonged training duration was a statistically significant predictor of higher peritonitis risk, but it was not related to shorter permanence in PD in our series. Identifying these patients since the training period would be useful to adapt training schedule as an early prevention strategy to minimize the risk of peritonitis and plan a preemptive retraining.


Subject(s)
Patient Education as Topic , Peritoneal Dialysis , Peritonitis/prevention & control , Renal Insufficiency, Chronic/therapy , Adult , Age Factors , Aged , Comorbidity , Female , Humans , Male , Middle Aged , Peritoneal Dialysis/adverse effects , Peritonitis/etiology , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/physiopathology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Unemployment
12.
Nefrología (Madrid) ; 40(6): 623-633, nov.-dic. 2020. ilus, tab
Article in Spanish | IBECS | ID: ibc-197198

ABSTRACT

La ecografía es una herramienta esencial en el manejo del paciente nefrológico que permite el diagnóstico, el seguimiento y la realización de intervencionismo sobre el riñón. La utilidad de los ultrasonidos en Nefrología no se circunscribe exclusivamente al estudio ecográfico del riñón. Mediante ecografía el nefrólogo puede, además, optimizar el manejo de la fístula arteriovenosa para hemodiálisis, medir el riesgo cardiovascular (grosor íntima-media), implantar catéteres centrales para hemodiálisis ecoguiados y ayudar en la colocación de los peritoneales, así como calcular la volemia del paciente mediante ecografía cardiaca básica, ecografía de la vena cava inferior y pulmonar. Desde el Grupo de Trabajo en Nefrología Diagnóstica e Intervencionista (GNDI) de la Sociedad Española de Nefrología (SEN) hemos elaborado este documento de consenso en el que se resumen las principales aplicaciones de la ecografía en Nefrología, incluyendo los requisitos técnicos básicos necesarios, el marco normativo y el nivel de capacitación de los nefrólogos en esta materia. El objetivo de este trabajo es promover la inclusión de la ecografía, tanto diagnóstica como intervencionista, en la práctica clínica habitual del nefrólogo y en la cartera de servicios de Nefrología con la finalidad de ofrecer un manejo diligente, eficiente e integral al paciente nefrológico


Ultrasound is an essential tool in the management of the nephrological patient allowing the diagnosis, monitoring and performance of kidney intervention. However, the usefulness of ultrasound in the hands of the nephrologist is not limited exclusively to the ultrasound study of the kidney. By ultrasound, the nephrologist can also optimize the management of arteriovenous fistula for hemodialysis, measure cardiovascular risk (mean intimate thickness), implant central catheters for ultrasound-guided HD, as well as the patient's volemia using basic cardiac ultrasound, ultrasound of the cava inferior vein and lungs. From the Working Group on Interventional Nephrology (GNDI) of the Spanish Society of Nephrology (SEN) we have prepared this consensus document that summarizes the main applications of ultrasound to Nephrology, including the necessary basic technical requirements, the framework normative and the level of training of nephrologists in this area. The objective of this work is to promote the inclusion of ultrasound, both diagnostic and interventional, in the usual clinical practice of the nephrologist and in the Nephrology Services portfolio with the final objective of offering diligent, efficient and comprehensive management to the nephrological patient


Subject(s)
Humans , Nephrology/education , Ultrasonography/standards , Kidney Diseases/diagnostic imaging , Societies, Medical , Ultrasonography/methods , Spain
14.
Kidney Med ; 2(5): 650-651, 2020.
Article in English | MEDLINE | ID: mdl-33089141

ABSTRACT

Peritonitis remains a primary challenge for the long-term success of peritoneal dialysis (PD) technique and one of the main reasons for catheter removal. Prevention and treatment of catheter-related infections are major concerns to avoid peritonitis. The use of taurolidine catheter-locking solution to avoid the development of a biofilm in the catheter's lumen has obtained good results in hemodialysis catheters for reducing infection rates, although there is scarce literature available regarding its utility in PD. We describe the case of a woman in her 60s who developed relapsing peritonitis due to Pseudomonas aeruginosa, with no possibility of removing peritoneal dialysis catheter because she was not a suitable candidate for hemodialysis. After the fourth peritonitis episode caused by Pseudomonas species, the use of taurolidine catheter-locking solution was initiated. She received a total of 9 doses, with a favorable microbiological and clinical outcome and no further relapses more than 10 months after taurolidine PD catheter lock treatment was started. We report the successful elimination of an aggressive bacteria after taurolidine PD catheter lock use, with no relevant adverse events.

15.
Rev. chil. obstet. ginecol. (En línea) ; 85(supl.1): S75-S89, set. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1138651

ABSTRACT

INTRODUCCIÓN: En Chile, los efectos maternos y perinatales de la pandemia por SARS-CoV-2 son aún desconocidos. GESTACOVID es un estudio multicéntrico que incluye embarazadas y puérperas hasta el día 42 con COVID-19. El objetivo de este estudio es presentar un informe preliminar, describiendo el impacto de la enfermedad en las embarazadas, factores de riesgo asociados y resultados perinatales. MÉTODOS: Estudio de cohorte descriptivo que incluye 661 pacientes enroladas entre el 7 de marzo y el 6 de julio de 2020, en 23 centros hospitalarios del país. Se analizaron variables demográficas, comorbilidades, características clínicas y del diagnóstico de COVID-19 y resultado materno y perinatal. RESULTADOS: Las pacientes hospitalizadas por COVID-19 tuvieron mayor prevalencia de hipertensión arterial crónica [10% vs 3%; OR=3,1 (1,5-6,79); p=0,003] y de diabetes tipo 1 y 2 [7% vs 2%; OR=3,2 (1,3-7,7); p=0,009] que las pacientes manejadas ambulatoriamente. Un IMC >40 kg/mt2 se asoció con un riesgo dos veces mayor de requerir manejo hospitalizado [OR=2,4 (1,2 - 4,6); p=0,009]. Aproximadamente la mitad de las pacientes (54%) tuvo un parto por cesárea, y un 8% de las interrupciones del embarazo fueron por COVID-19. Hasta la fecha de esta publicación, 38% de las pacientes continuaban embarazadas. Hubo 21 PCR positivas en 316 neonatos (6,6%), la mayoría (17/21) en pacientes diagnosticadas por cribado universal. CONCLUSIONES: Las embarazadas con COVID-19 y comorbilidades como diabetes, hipertensión crónica y obesidad mórbida deben ser manejadas atentamente y deberán ser objeto de mayor investigación. La tasa de transmisión vertical requiere una mayor evaluación para diferenciar el mecanismo y tipo de infección involucrada.


INTRODUCTION: In Chile, effects of the SARS-CoV-2 infection in pregnant women are unknown. GESTACOVID is a multicenter collaborative study including pregnant women and those in the postpartum period (until 42 days) who have had COVID-19. The purpose of this study is to report our preliminary results describing the clinical impact of COVID-19 in pregnant women, the associated risk factors and perinatal results. METHODS: Descriptive cohort study including 661 patients between April 7th and July 6th, 2020, in 23 hospitals. Demographical, comorbidities, clinical and diagnostic characteristics of COVID-19 disease and maternal and perinatal outcomes were analyzed. RESULTS: Pregnant women with COVID-19 admitted to the hospital were more likely to have chronic hypertension [10% vs 3%; OR=3.1 (1.5-6.79); p=0,003] and diabetes type 1 and 2 [7% vs 2%; OR=3.2 (1.3-7.7); p=0.009] than those with outpatient management. A body mass index of >40 kg/mt2 was associated with two-fold higher risk of hospitalization [OR=2.4 (1.2-4.6); p=0.009]. Almost half of patients (54%) were delivered by cesarean section, and 8% of the medically indicated deliveries were due to COVID-19. So far, 38% of the patients are still pregnant. Among 316 newborns, there were 21 positive PCR tests (6.6%), mostly from asymptomatic mothers undergoing universal screening. CONCLUSIONS: Pregnant women with COVID-19 and comorbidities such as diabetes, chronic hypertension and morbid obesity need a close follow up and should be a matter for further research. Vertical transmission of COVID-19 should be thoroughly studied to define the mechanisms and type of infection involved.


Subject(s)
Humans , Female , Pregnancy , Infant, Newborn , Adult , Pneumonia, Viral/epidemiology , Pregnancy Complications, Infectious/epidemiology , Coronavirus Infections/epidemiology , Pandemics , Outpatients , Signs and Symptoms , Pregnancy Outcome , Comorbidity , Cesarean Section/statistics & numerical data , Chile/epidemiology , Mass Screening , Epidemiology, Descriptive , Risk Factors , Cohort Studies , Abortion, Induced/statistics & numerical data , Infectious Disease Transmission, Vertical/statistics & numerical data , Critical Care , Diabetes Mellitus/epidemiology , Betacoronavirus , Hospitalization , Hypertension/epidemiology , Obesity/epidemiology
16.
Nefrologia (Engl Ed) ; 40(6): 623-633, 2020.
Article in English, Spanish | MEDLINE | ID: mdl-32773327

ABSTRACT

Ultrasound is an essential tool in the management of the nephrological patient allowing the diagnosis, monitoring and performance of kidney intervention. However, the usefulness of ultrasound in the hands of the nephrologist is not limited exclusively to the ultrasound study of the kidney. By ultrasound, the nephrologist can also optimize the management of arteriovenous fistula for hemodialysis, measure cardiovascular risk (mean intimate thickness), implant central catheters for ultrasound-guided HD, as well as the patient's volemia using basic cardiac ultrasound, ultrasound of the cava inferior vein and lungs. From the Working Group on Interventional Nephrology (GNDI) of the Spanish Society of Nephrology (SEN) we have prepared this consensus document that summarizes the main applications of ultrasound to Nephrology, including the necessary basic technical requirements, the framework normative and the level of training of nephrologists in this area. The objective of this work is to promote the inclusion of ultrasound, both diagnostic and interventional, in the usual clinical practice of the nephrologist and in the Nephrology Services portfolio with the final objective of offering diligent, efficient and comprehensive management to the nephrological patient.


Subject(s)
Consensus , Nephrology/education , Ultrasonics/education , Ultrasonography, Interventional , Advisory Committees , Arteriovenous Shunt, Surgical/education , Catheterization/methods , Clinical Competence , Echocardiography , Humans , Image-Guided Biopsy , Nephrology/instrumentation , Renal Dialysis/methods , Spain , Ultrasonics/instrumentation
17.
AIDS Care ; 32(10): 1262-1267, 2020 10.
Article in English | MEDLINE | ID: mdl-32476442

ABSTRACT

People who use injection drugs (PWID) experience high rates of HIV acquisition and, as a result of lower rates of optimal access and adherence to combination antiretroviral therapy (ART), experience worse HIV treatment outcomes than other key affected populations. However, the incidence and risk factors for the development of AIDS among HIV-positive PWID have not been completely described. We used data from a community-recruited prospective cohort of HIV-positive PWID in Vancouver, Canada, a setting with universal no-cost ART and a comprehensive clinical monitoring registry. We used multivariable extended Cox models to identify factors associated with time to AIDS. Between 1996 and 2017, 396 participants, including 140 (35.4%) women, were followed for a median of 39.0 months (interquartile range: 16.6-76.2), among whom 165 (41.7%) developed AIDS. In a multivariable model, homelessness (Adjusted Hazard Ratio [AHR] = 1.76 (1.18-2.61)) and injection drug use within the preceding six months (AHR = 1.74 (1.17-2.58)) were independently associated with a higher risk of developing AIDS. Despite widespread scale-up of programmes to improve ART utilization, significant risk factors for the development of AIDS remain among HIV-positive PWID in this setting.


Subject(s)
Acquired Immunodeficiency Syndrome , HIV Infections , Substance Abuse, Intravenous , Acquired Immunodeficiency Syndrome/complications , Acquired Immunodeficiency Syndrome/drug therapy , Acquired Immunodeficiency Syndrome/epidemiology , Canada/epidemiology , Female , HIV Infections/complications , HIV Infections/drug therapy , HIV Infections/epidemiology , Humans , Male , Pharmaceutical Preparations , Prospective Studies , Risk Factors , Substance Abuse, Intravenous/complications , Substance Abuse, Intravenous/epidemiology
19.
Clin Exp Nephrol ; 24(4): 349-355, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31900728

ABSTRACT

BACKGROUND: Causes of non-resuming peritoneal dialysis (PD) after complicated peritonitis requiring peritoneal catheter (PC) removal remain poorly studied. METHODS: We reviewed all peritonitis episodes in our center between 1997 and 2017. Patients who restarted PD after PC removal (Group 1) were compared to those who did not (Group 2), identifying the causes. RESULTS: Of 284 peritonitis episodes, PC was removed in 48 patients (16.9%). In 18 (37.5%) patients PC was reinserted, and PD successfully resumed in all, with a median duration of PD afterwards of 14.1 months. In other 30 (62.5%) reinsertion of PC was not attempted. Causes of non-reinsertion were: transfer to hemodialysis 76.6% (n = 23), death 16.7% (n = 5) and transplantation 6.7% (n = 2). Hemodialysis switch was due to non-medical reasons in 47.8% (n = 11) including fear of peritonitis, family decision and social dependence. Group 1 was younger (p = 0.041), with lower Charlson index (p = 0.045) and higher men proportion (p = 0.049). Group 1 had a better patient survival than group 2 (survival at 24 months: 67% and 53%, respectively; log-rank test p: 0.01). There were no differences in survival between groups when adjusted for significant basal characteristics. CONCLUSIONS: Resuming PD after severe peritonitis requiring PC removal is feasible but a high proportion of patients do not restart PD for non-medical reasons, usually older patients with higher Charlson index. A properly structured interview would be a useful tool that could improve return to technique in these patients.


Subject(s)
Device Removal/statistics & numerical data , Peritoneal Dialysis/instrumentation , Peritonitis , Aged , Catheters , Female , Humans , Male , Middle Aged , Peritoneal Dialysis/statistics & numerical data , Retrospective Studies
20.
Kidney360 ; 1(5): 354-358, 2020 May 28.
Article in English | MEDLINE | ID: mdl-35369373

ABSTRACT

Background: Peritoneal dialysis (PD) is the RRT of choice in 15% of patients with CKD and has multiple advantages over hemodialysis. PD leaks can prompt technique failure and dropout. Use of peritoneal scintigraphy (PS) for diagnosis of PD leaks has declined in favor of more complex and expensive tests. We analyzed the utility of PS for PD leak diagnosis in our center. Methods: We retrospectively analyzed all PS done in our center from January 2000 until December 2018, inclusive, in all patients on PD with a suspected dialysate leak. Results: A total of 39 PS procedures were done in 36 patients on PD in the study period. Of those, 81% were male and 11% had CKD due to polycystic kidney disease. During this period, 23 leaks were diagnosed, showing an incidence of 6% (three episodes per patient per year). In all cases with negative PS, other tests did not confirm a peritoneal dialysate leak. Conclusions: PS is a safe, inexpensive, reproducible, and highly effective diagnostic tool for peritoneal dialysate leaks that allows nephrologists to tailor or stop PD therapy if required. In our opinion, it should be the first-line imaging test to diagnose PD leaks with minimum exposure to radiation, contrast, or other substances that could irritate the peritoneal membrane. We believe PS should be considered as the initial test of choice to diagnose this PD complication as soon as possible, minimizing technique failure and dropout due to leaks.


Subject(s)
Peritoneal Dialysis , Dialysis Solutions , Humans , Male , Peritoneal Dialysis/adverse effects , Peritoneum , Radionuclide Imaging , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...