1.
Int J Radiat Oncol Biol Phys ; 116(2): 305-313, 2023 06 01.
Article in English | MEDLINE | ID: mdl-36724859

ABSTRACT

PURPOSE: In 2021, the Canadian Organization of Medical Physicists (COMP) conducted its first equity, diversity, and inclusion Climate Survey. The membership's experiences of inclusion, belonging, professional opportunities, discrimination, microaggressions, racism, and harassment in their professional lives are presented. METHODS AND MATERIALS: The ethics-reviewed survey was distributed in English and French to full members of COMP. Participants responded to questions covering demographics and professional climate. Simple descriptive statistics were used to measure frequency of responses. Data pertaining to impressions on the climate within the profession were compared using nonparametric statistical tests. RESULTS: The survey was distributed to 649 eligible members; 243 (37%) responded, and 214 (33%) provided full response sets. From the full response sets, findings showed that in general, age, highest academic degree, and racial and ethnic distribution trends of medical physicists were comparable with previously collected data and/or the Canadian population. The experiences of respondents relating to harassment in the workplace and perception of climate are reported and provide a useful benchmark for future assessments of interventions or training programs. In the workplace, fewer women (58%) reported having professional opportunities compared with men (70%). The survey also found that 17% of respondents (most of whom were women) directly or indirectly experienced sexual harassment in the workplace within the past 5 years. Finding that 23% of survey respondents identified as having a disability is a valuable reminder that accommodations in the workplace are necessary for more than 1 in every 5 medical physicists working in clinics. CONCLUSIONS: This study provided insight into the diversity and experiences of medical physicists in Canada. The majority of respondents had positive perceptions about their professional environment. However, equity-lacking groups were identified, such as women, underrepresented minorities, Indigenous peoples, and people with visible and invisible disabilities.


Subject(s)
Diversity, Equity, Inclusion , Sexual Harassment , Male , Humans , Female , Canada , Surveys and Questionnaires , Attitude
2.
Magn Reson Med ; 85(4): 2327-2333, 2021 04.
Article in English | MEDLINE | ID: mdl-33058317

ABSTRACT

PURPOSE: To evaluate the impact of emerging conductor technology on RF coils. Performance and resulting image quality of thin or alternate conductors (eg, aluminum instead of copper) and thicknesses (9-600 µm) are compared in terms of SNR. METHODS: Eight prototype RF coils (15 cm × 15 cm square loops) were constructed and bench-tested to measure quality factor. The coils used 6-mm-wide conducting strips of either copper or aluminum of a few different thicknesses (copper: 17, 32, 35, 127, 600 µm; aluminum: 9, 13, 20, 127 µm) on acetate projector sheets for backing. Corresponding image SNR was measured at 0.48 tesla (20.56 MHz). RESULTS: The coils spanned a range of unloaded quality factors from 89 to 390 and a fivefold range of losses. The image SNRs were consistent with the coils' bench-measured efficiencies (0.33-0.73). Thin aluminum conductors (9 µm) led to the highest reduction in SNR (65% that of 127 µm copper). Thin copper (<32 µm) conductors lead to a much smaller decrease in SNR (approximately 10%) compared to 127 µm copper. No performance difference was observed between 127 µm thick copper and aluminum. The much thicker 600 µm copper bars only yield a 5% improvement in SNR. CONCLUSION: Even at 0.48 tesla, copper RF coil conductors much thinner than those in conventional construction can be used while maintaining SNR greater than 50% that of thick copper. These emerging coil conductor technologies enable RF coil functionality that cannot be achieved otherwise.


Subject(s)
Aluminum , Copper , Equipment Design , Magnetic Resonance Imaging , Phantoms, Imaging , Radio Waves
3.
Biomed Phys Eng Express ; 6(3): 037002, 2020 04 09.
Article in English | MEDLINE | ID: mdl-33438681

ABSTRACT

PURPOSE: The RF coils for magnetic resonance image guided radiotherapy (MRIgRT) may be constructed using thin and/or low-density conductors, along with thinner enclosure materials. This work measures the surface dose increases for lightweight conductors and enclosure materials in a magnetic field parallel to a 6 MV photon beam. METHODS: Aluminum and copper foils (9-127 µm thick), as well as samples of polyimide (17 µm) and polyester (127 µm) films are positioned atop a polystyrene phantom. A parallel plate ion chamber embedded into the top of the phantom measures the surface dose in 6 MV photon beam. Measurements (% of dose at the depth of maximum dose) are performed with and without a parallel magnetic field (0.22T at magnet center). RESULTS: In the presence of a magnetic field, the unobstructed surface dose is higher (31.9%Dmax versus 22.2%Dmax). The surface dose is found to increase linearly with thickness for thin (<25 µm) copper (0.339%Dmax µm-1) and aluminum (0.116%Dmax µm-1) foils. In the presence of a magnetic field the slope is lower (copper: 0.16%Dmax µm-1, aluminum: 0.06%Dmax µm-1). The effect of in-beam foils is reduced due to partial shielding of the surface from contaminant electrons. Copper causes a surface dose increase ≈3 times higher than aluminum of the same thickness, consistent with their relative electron density. Polyester film (127µm) increases the surface dose (to 35% Dmax with field) about as much as a gown (36% Dmax with field), while the increase with polyimide film (17µm) is less than 1% above the open field dose. CONCLUSIONS: Thin copper and aluminum conductors increase surface dose by an amount comparable to a hospital gown. Similarly, enclosure materials made of thin polyester or polyimide film increase surface dose by only a few %Dmax in excess of an unobstructed beam. Based on measurements in this study, in-beam, surface RF coils are feasible for MRIgRT systems.


Subject(s)
Aluminum/chemistry , Copper/chemistry , Magnetic Fields , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Electrons , Monte Carlo Method , Particle Accelerators , Phantoms, Imaging , Radiation , Radiation Dosage , Radio Waves , Radiotherapy Dosage , Radiotherapy, Image-Guided