Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JMIR Form Res ; 6(11): e37280, 2022 Nov 04.
Article in English | MEDLINE | ID: mdl-35481559

ABSTRACT

BACKGROUND: Atrial fibrillation affects approximately 4% of the world's population and is one of the major causes of stroke, heart failure, sudden death, and cardiovascular morbidity. It can be difficult to diagnose when asymptomatic or in the paroxysmal stage, and its natural history is not well understood. New wearables and connected devices offer an opportunity to improve on this situation. OBJECTIVE: We aimed to validate an algorithm for the automatic detection of atrial fibrillation from a single-lead electrocardiogram taken with a smartwatch. METHODS: Eligible patients were recruited from 4 sites in Paris, France. Electrocardiograms (12-lead reference and single lead) were captured simultaneously. The electrocardiograms were reviewed by independent, blinded board-certified cardiologists. The sensitivity and specificity of the algorithm to detect atrial fibrillation and normal sinus rhythm were calculated. The quality of single-lead electrocardiograms (visibility and polarity of waves, interval durations, heart rate) was assessed in comparison with the gold standard (12-lead electrocardiogram). RESULTS: A total of 262 patients (atrial fibrillation: n=100, age: mean 74.3 years, SD 12.3; normal sinus rhythm: n=113, age: 61.8 years, SD 14.3; other arrhythmia: n=45, 66.9 years, SD 15.2; unreadable electrocardiograms: n=4) were included in the final analysis; 6.9% (18/262) were classified as Noise by the algorithm. Excluding other arrhythmias and Noise, the sensitivity for atrial fibrillation detection was 0.963 (95% CI lower bound 0.894), and the specificity was 1.000 (95% CI lower bound 0.967). Visibility and polarity accuracies were similar (1-lead electrocardiogram: P waves: 96.9%, QRS complexes: 99.2%, T waves: 91.2%; 12-lead electrocardiogram: P waves: 100%, QRS complexes: 98.8%, T waves: 99.5%). P-wave visibility accuracy was 99% (99/100) for patients with atrial fibrillation and 95.7% (155/162) for patients with normal sinus rhythm, other arrhythmias, and unreadable electrocardiograms. The absolute values of the mean differences in PR duration and QRS width were <3 ms, and more than 97% were <40 ms. The mean difference between the heart rates from the 1-lead electrocardiogram calculated by the algorithm and those calculated by cardiologists was 0.55 bpm. CONCLUSIONS: The algorithm demonstrated great diagnostic performance for atrial fibrillation detection. The smartwatch's single-lead electrocardiogram also demonstrated good quality for physician use in daily routine care. TRIAL REGISTRATION: ClinicalTrials.gov NCT04351386; http://clinicaltrials.gov/ct2/show/NCT04351386.

2.
J Clin Sleep Med ; 17(6): 1217-1227, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33590821

ABSTRACT

STUDY OBJECTIVES: To assess the diagnostic performance of a nonintrusive device placed under the mattress to detect sleep apnea syndrome. METHODS: One hundred eighteen patients suspected to have obstructive sleep apnea syndrome completed a night at a sleep clinic with a simultaneous polysomnography (PSG) and recording with the Withings Sleep Analyzers. PSG nights were scored twice: first as simple polygraphy, then as PSG. RESULTS: Average (standard deviation) apnea-hypopnea index from PSG was 31.2 events/h (25.0) and 32.8 events/h (29.9) according to the Withings Sleep Analyzers. The mean absolute error was 9.5 events/h. The sensitivity, specificity, and area under the receiver operating characteristic curve at thresholds of apnea-hypopnea index ≥ 15 events/h were, respectively, sensitivity (Se)15 = 88.0%, specificity (Sp)15 = 88.6%, and area under the receiver operating characteristic curve (AUROC) 15 = 0.926. At the threshold of apnea-hypopnea index ≥ 30 events/h, results included Se30 = 86.0%, Sp30 = 91.2%, AUROC30 = 0.954. The average total sleep time from PSG and the Withings Sleep Analyzers was 366.6 (61.2) and 392.4 (67.2) minutes, sleep efficiency was 82.5% (11.6) and 82.6% (11.6), and wake after sleep onset was 62.7 (48.0) and 45.2 (37.3) minutes, respectively. CONCLUSIONS: Withings Sleep Analyzers accurately detect moderate-severe sleep apnea syndrome in patients suspected of sleep apnea syndrome. This simple and automated approach could be of great clinical value given the high prevalence of sleep apnea syndrome in the general population. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Validation of Withings Sleep for the Detection of Sleep Apnea Syndrome; URL: https://clinicaltrials.gov/ct2/show/NCT04234828; Identifier: NCT04234828.


Subject(s)
Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Humans , Polysomnography , ROC Curve , Sleep
SELECTION OF CITATIONS
SEARCH DETAIL
...