Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Biomech (Bristol, Avon) ; 99: 105756, 2022 10.
Article in English | MEDLINE | ID: mdl-36063742

ABSTRACT

BACKGROUND: Arthroplasty with artificial disc replacement for surgical treatment of cervical spine degeneration was introduced with the notion that motion-preserving approaches would prevent development of adjacent segment disease. Though clinical outcomes favor arthroplasty over the commonly used anterior cervical discectomy with fusion approach, clinical studies confirming the biomechanical basis of these results are lacking. The aim of this study was to compare intervertebral kinematics between arthroplasty and fusion patients 6.5 years post-surgery during physiological motion of the neck. METHODS: Using a biplane dynamic X-ray system, computed tomography imaging and model based tracking algorithms, three dimensional intervertebral kinematics were measured during neck axial rotation and extension in 14 patients treated for cervical radiculopathy with fusion (n = 8) or arthroplasty (n = 6). The measurements were performed at 2-year (baseline) and 6.5 year post-surgical time points, with the main interest being in the interaction between surgery types and time points. 3 translations and 3 rotations were investigated for the index (C5C6), and upper- (C4C5) and lower adjacent levels (C6C7). FINDINGS: Surgery-time interaction was significant for axial rotation (P < 0.04) and flexion-extension rotation (P < 0.005) in C4C5 during neck axial rotation, left-right translation (P < 0.04) in C5C6 and anterior-posterior translation in C6C7 (P < 0.04) during neck extension. In contrast with the expectations, axial rotation and flexion-extension decreased in C4C5 during neck rotation and anterior-posterior translation decreased in C6C7 during neck extension for fusion. INTERPRETATION: The findings do not support the notion that adjacent segment motion increases after fusion.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Spinal Fusion , Total Disc Replacement , Biomechanical Phenomena , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/physiology , Cervical Vertebrae/surgery , Diskectomy/methods , Humans , Intervertebral Disc/diagnostic imaging , Intervertebral Disc/surgery , Intervertebral Disc Degeneration/surgery , Range of Motion, Articular/physiology , Spinal Fusion/methods , Total Disc Replacement/methods , Treatment Outcome
2.
PLoS One ; 15(8): e0237350, 2020.
Article in English | MEDLINE | ID: mdl-32780779

ABSTRACT

OBJECTIVE: To compare changes in foraminal motion at two time points post-surgery between artificial disc replacement (ADR) and anterior cervical discectomy and fusion (ACDF). METHODS: Eight ACDF and 6 ADR patients (all single-level C5-6) were tested at 2 years (T1) and 6.5 years (T2) post-surgery. The minimum foraminal height (FH.Min) and width (FW.Min) achieved during neck axial rotation and extension, and the range of these dimensions during motion (FH.Rn and FW.Rn, respectively) were measured using a biplane dynamic x-ray system, CT imaging and model-based tracking while patients performed neck axial rotation and extension tasks. Two-way mixed ANOVA was employed for analysis. RESULTS: In neck extension, significant interactions were found between year post-surgery and type of surgery for FW.Rn at C5-6 (p<0.006) and C6-7 (p<0.005), and for FH.Rn at C6-7 (p<0.01). Post-hoc analysis indicated decreases over time in FW.Rn for ACDF (p<0.01) and increases in FH.Rn for ADR (p<0.03) at the C6-7 adjacent level. At index level, FW.Rn was comparable between ACDF and ADR at T1, but was smaller for ACDF than for ADR at T2 (p<0.002). In axial rotation, differences were found between T1 and T2 but did not depend on type of surgery (p>0.7). CONCLUSIONS: Changes were observed in the range of foraminal geometry at adjacent levels from 2 years to 6.5 years post-surgery that were different between ACDF and ADR for neck extension. These changes are contrary to the notion that motion at adjacent levels continue to increase following ACDF as compared to ADR over the long term.


Subject(s)
Cervical Vertebrae/physiopathology , Diskectomy/adverse effects , Intervertebral Disc Degeneration/surgery , Range of Motion, Articular , Spinal Fusion/adverse effects , Total Disc Replacement/adverse effects , Adult , Aged , Biomechanical Phenomena , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/surgery , Female , Follow-Up Studies , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Postoperative Period , Tomography, X-Ray Computed , Total Disc Replacement/instrumentation , Treatment Outcome
3.
J Spine Surg ; 6(1): 18-25, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32309642

ABSTRACT

BACKGROUND: Post-surgical changes in adjacent segment motion are considered a factor in further development of degeneration and cervical radiculopathy. The objective was to examine the extent of correlations between physiological motion of cervical foramina and long-term patient reported outcomes (PRO). METHODS: Biplane X-ray imaging and CT-based markerless tracking were used to measure 3D static and dynamic dimensions during neck axial rotation and extension from 18 patients treated for C5-6 radiculopathy with fusion or arthroplasty. Minimum foraminal height (FH.Min) and width (FW.Min), and their range (FH.Range and FW.Range) achieved during a motion task were calculated for adjacent levels (C4-5 and C6-7) at 2.0±0.6 years post-surgery. The modified Japanese Orthopedic Association score (mJOAS), the Neck Disability Index (NDI) including the visual analogue scale (VAS) for neck and arm pain, and the EuroQol EQ-5D score were recorded at 6.5±1.1 years post-surgery. The relationships between 6.5-year outcomes and 2-year foraminal motion were examined using regression. RESULTS: Worsening patient-reported outcomes were generally associated with lower values of FW.Min (P<0.05 to P<0.008), the associations being stronger for neck extension (r2 up to 0.43). Dynamic foraminal measurements from the C6-7 level more significantly and consistently correlated with mJOAS, EQ-5D and NDI Arm Pain VAS (r2=0.27 to 0.43; P<0.03 to P<0.008), whereas those from the C4-5 level correlated with NDI Neck Pain VAS (r2=0.33; P<0.02). CONCLUSIONS: Dynamic 3D foraminal dimensions at 2-year post-surgery, notably FW.Min measured in neck extension at adjacent levels, were associated with PRO at 6.5 years post-surgery. These relationships provide insight into the motion related factors in development of pain and loss of function, and may help develop markers or objective outcome measures.

4.
Spine J ; 18(4): 575-583, 2018 04.
Article in English | MEDLINE | ID: mdl-28882520

ABSTRACT

BACKGROUND: Changes in the dimensions of the cervical neural foramina (CNF) are considered to be a key factor in nerve root compression and development of cervical radiculopathy. However, to what extent foraminal geometry differs between patients who underwent anterior cervical discectomy and fusion (ACDF) and those who underwent total disc arthroplasty with an artificial disc (AD) during physiological motion is largely unknown. PURPOSE: The objective of this study is to compare CNF dimensions during physiological neck motion between ACDF and AD. STUDY DESIGN/SETTING: This is a retrospective comparative analysis of prospectively collected, consecutive, non-randomized series of patients at a single institution. PATIENT SAMPLE: A total of 16 single-level C5-C6 ACDF (4 males, 12 females; 28-71 years) and 7 single-level C5-C6 cervical arthroplasty patients (3 males, 4 females; 38-57 years), at least 12 months after surgery (23.6±6.8 months) were included. OUTCOME MEASURES: Patient demographics, preoperative magnetic resonance imaging (MRI)-based measurements of cervical spine degeneration, and 2-year postoperative measurements of dynamic foraminal geometry were the outcome measures. METHODS: Biplane X-ray images were acquired during axial neck rotation and neck extension. A computed tomography scan was also acquired from C3 to the first thoracic vertebrae. The subaxial cervical vertebrae (C3-C7) were reconstructed into three-dimensional (3D) bone models for use with model-based tracking. Foraminal height (FH) was calculated as the 3D distance between the superior point of the inferior pedicle and the inferior point of the superior pedicle using custom software. Foraminal width (FW) was similarly calculated as the 3D distance between the anterolateral aspect of the superior vertebral body inferior notch and the posterolateral aspect of the inferior vertebral body superior notch. Dynamic foraminal dimensions were quantified as the minimum (FH.Min, FW.Min), the range (FH.Range, FW.Range), and the median (FH.Med, FW.Med) of each trial and then averaged over trials. Mixed model analysis of variance framework was used to examine the differences between ACDF and AD groups. The initial severity of disc degeneration as determined from preoperative MRI images was introduced as covariates in the models. RESULTS: At the operated level (C5-C6), FH.Med and FH.Range were smaller in ACDF than in AD during axial rotation and neck extension (p<.003 to p<.05). At the superior adjacent level (C4-C5), no significant difference was found. At the inferior adjacent level (C6-C7), FW.Range was greater in ACDF than in AD during axial rotation and extension (p<.05). At the non-adjacent level (C3-C4), FW.Range was greater in ACDF than in AD during extension (p<.008). CONCLUSIONS: This study demonstrated decreases in foraminal dimensions and their range for ACDF compared with AD at the operated level. In contrast, it demonstrated increases in the range of foraminal dimensions during motion for ACDF compared with AD at the non-operated segments. Together, these data support the notion that increased mobility at the non-operated segments after ACDF may contribute to a greater risk for adjacent segment degeneration. Because of the significant presence of range variables in the findings, the current data also indicate that a dynamic evaluation is likely more appropriate for evaluation of the differences in foramina between ACDF and AD than a static evaluation.


Subject(s)
Cervical Vertebrae/surgery , Postoperative Complications/epidemiology , Spinal Fusion/methods , Total Disc Replacement/methods , Adult , Female , Humans , Intervertebral Disc Degeneration/surgery , Male , Middle Aged , Range of Motion, Articular , Spinal Fusion/adverse effects , Total Disc Replacement/adverse effects
5.
Spine J ; 10(6): 497-504, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20359957

ABSTRACT

BACKGROUND CONTEXT: Previous research has quantified cervical spine motion with conventional measurement techniques (eg, cadaveric studies, motion capture systems, and fluoroscopy), but these techniques were not designed to accurately measure three-dimensional (3D) dynamic cervical spine motion under in vivo conditions. PURPOSE: The purposes of this study were to characterize the accuracy of model-based tracking for measuring 3D dynamic cervical spine kinematics and to demonstrate its in vivo application. STUDY DESIGN: Through accuracy assessment and application of technique, in vivo cervical spine motion was measured. METHODS: The accuracy of model-based tracking for measuring cervical spine motion was determined in an in vitro experiment. Tantalum beads were implanted into the vertebrae of an ovine specimen, and biplane X-ray images were acquired as the specimen's neck was manually moved through neck extension and axial neck rotation. The 3D position and orientation of each cervical vertebra were determined from the biplane X-ray images using model-based tracking. For comparison, the position and orientation of each vertebra were also determined by tracking the position of the implanted beads with dynamic radiostereometric analysis. To demonstrate in vivo application of this technique, biplane X-ray images were acquired as a human subject performed two motion tasks: neck extension and axial neck rotation. The positions and orientations of each cervical vertebra were determined with model-based tracking. Cervical spine motion was reported with standard kinematic descriptions of translation and rotation. RESULTS: The in vitro validation demonstrated that model-based tracking is accurate to within +/-0.6 mm and +/-0.6 degrees for measuring cervical spine motion. For the in vivo application, there were significant rotations about all three anatomical axes for both the neck extension and axial neck rotation motion tasks. CONCLUSIONS: Model-based tracking is an accurate technique for measuring in vivo, 3D, dynamic cervical spine motion. Preliminary data acquired using this technique are in agreement with previous studies. It is anticipated that this experimental approach will enhance our understanding of cervical spine motion under normal and pathologic conditions.


Subject(s)
Biomechanical Phenomena/physiology , Cervical Vertebrae/diagnostic imaging , Imaging, Three-Dimensional/methods , Adult , Animals , Cervical Vertebrae/physiology , Humans , Male , Movement/physiology , Radiography , Rotation , Sheep , X-Rays
6.
Spine (Phila Pa 1976) ; 33(24): 2618-22, 2008 Nov 15.
Article in English | MEDLINE | ID: mdl-19011543

ABSTRACT

STUDY DESIGN: Biomechanical analysis. OBJECTIVE: To determine the relative strengths of 2 different forms of revision spinal instrumentation using a validated, constant load, cyclic testing mechanism. SUMMARY OF BACKGROUND DATA: Spinal fusion with instrumentation procedures are on the rise. As such, so are revision procedures. A few studies have looked at revision instrumentation techniques. Both increased pedicle screw diameter as well as cement augmentation of pedicle screw fixation have been proposed, used clinically and tested biomechanically. To our knowledge, no comparative study exists between these techniques. METHODS: Using an instron servohydraulic loading machine, we tested pedicle screws inserted in both the anatomic (angled) and Roy-Camille (straight) insertion technique with both larger diameter (8 mm) pedicle screws, as well as standard diameter (6 mm) pedicle screws augmented with polymethylmethacrylate bone cement. Each of these techniques was subjected to constant load under cyclic conditions for 2000 cycles at 2 Hz. Computerized data collection was used at all time points. Comparisons were made between primary instrumentation data (previously published) and large diameter screws for revision. Further comparisons were made between large diameter screws and cement augmented screws. RESULTS: The larger diameter screws compared with the cement augmented screws showed significant differences in: initial stiffness with straight insertion technique (P < 0.01), stiffness damage with straight insertion technique (P < 0.01), and creep damage with straight insertion technique (P = 0.01). There was also a significant difference between large diameter and primary instrumentation technique all calculated values (P

Subject(s)
Bone Cements/therapeutic use , Bone Screws , Lumbar Vertebrae/surgery , Polymethyl Methacrylate/therapeutic use , Spinal Fusion/methods , Aged , Biomechanical Phenomena , Female , Humans , Male , Materials Testing , Prosthesis Design , Prosthesis Failure , Reoperation , Spinal Fusion/instrumentation , Stress, Mechanical
SELECTION OF CITATIONS