Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Expert Rev Cardiovasc Ther ; 21(7): 507-517, 2023.
Article in English | MEDLINE | ID: mdl-37246899

ABSTRACT

INTRODUCTION: The prevalence of congenital heart disease (CHD) is steadily increasing among adults. Atrial arrhythmias are frequent late complications and are associated with substantial morbidity. AREAS COVERED: We discuss key considerations regarding management strategies for atrial arrhythmias in common forms of CHD and offer future perspectives. EXPERT OPINION: An appreciation of the types of atrial arrhythmias encountered in patients with diverse forms of CHD, combined with the growing clinical and research experience, appears to be yielding favorable results, whereas little progress has been made on the antiarrhythmic drug front, indications for anticoagulation have considerably evolved. Advances in interventional techniques have propelled catheter ablation to the forefront to treat a variety of atrial arrhythmias in patients with complex CHD. Nevertheless, much work remains to be done to elucidate underlying pathophysiology, triggers, and critical substrates that predispose patients with specific CHD malformations to develop atrial arrhythmias. Future advances could allow for the implementation of individualized, possibly preemptive, approaches to arrhythmia management. With the prevalence of atrial fibrillation on the rise in the aging population with CHD, concerted efforts must be directed toward optimizing patient selection for catheter ablation as well as refining procedural aspects to safely and more effectively improve long-term outcomes.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Defects, Congenital , Adult , Humans , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/therapy , Atrial Fibrillation/epidemiology , Heart Defects, Congenital/complications , Heart Defects, Congenital/therapy , Anti-Arrhythmia Agents/therapeutic use , Catheter Ablation/methods , Prevalence
2.
Expert Rev Cardiovasc Ther ; 21(3): 227-236, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36852632

ABSTRACT

BACKGROUND: Robotic magnetic navigation (RMN) has emerged as a potential solution to overcome challenges associated with catheter ablation of arrhythmias in patients with congenital heart disease (CHD). OBJECTIVES: To assess safety and efficacy of RMNguided catheter ablation in patients with CHD. DESIGN AND METHODS: A systematic review and pooled analysis was conducted on patients with CHD who underwent RMNguided catheter ablation. Random effects models were used to generate pooled estimates with the inverse variance method used for weighting studies. RESULTS: Twentyfour nonoverlapping records included 167 patients with CHD, mean age 36.5 years, 44.6% female. Type of CHD was simple in 27 (16.2%), moderate in 32 (19.2%), and complex in 106 (63.5%). A total of 202 procedures targeted 260 arrhythmias, the most common being macroreentrant atrial circuits. The mean procedural duration was 207.5 minutes, with a mean fluoroscopy time of 12.1 minutes. The pooled acute success rate was 89.2% [95% CI (77.8%, 97.4%)]. Freedom from arrhythmia recurrence was 84.5% [95% CI (72.5%, 94.0%)] over a mean follow-up of 24.3 months. The procedural complication rate was 3.5% with no complication attributable to RMN technology. CONCLUSION: RMN-guided ablation appears to be safe and effective across a variety of arrhythmia substrates and types of CHD.


Subject(s)
Catheter Ablation , Heart Defects, Congenital , Robotic Surgical Procedures , Humans , Female , Adult , Male , Robotic Surgical Procedures/adverse effects , Robotic Surgical Procedures/methods , Treatment Outcome , Heart Defects, Congenital/complications , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Magnetic Phenomena
3.
CJC Pediatr Congenit Heart Dis ; 2(6Part A): 404-413, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38161682

ABSTRACT

Arrhythmias are a common complication associated with tetralogy of Fallot (ToF), one of the most prevalent forms of congenital heart disease. As illustrated by this case-based review, various forms of arrhythmias can be encountered across the lifespan of patients with ToF, from infancy to older adulthood. These include atrioventricular block, junctional ectopic tachycardia, and atrial and ventricular arrhythmias. Arrhythmias have important implications on the health and quality of life of patients with ToF and require treatment by caregivers with dedicated expertise. The choice of pharmacologic and/or interventional therapies to alleviate symptoms, avoid complications, and mitigate risks depends in part on the type, severity, and frequency of the arrhythmia, as well as on the particularities of individual clinical scenarios. Preventing, monitoring for, and managing arrhythmias are an integral component of the care of patients with ToF throughout their lifespan that is critical to optimizing health outcomes.


L'arythmie est une complication fréquemment associée à la tétralogie de Fallot (TF), l'une des cardiopathies congénitales les plus courantes. Dans le présent article de synthèse basé sur des études de cas, nous illustrons les différentes formes d'arythmie tout au long de la vie des patients atteints de la TF, de la petite enfance à l'âge adulte avancé. Les formes d'arythmie décrites incluent le bloc atrioventriculaire, la tachycardie jonctionnelle ectopique et les arythmies auriculaire et ventriculaire. L'arythmie a des répercussions importantes sur l'état de santé et sur la qualité de vie des patients atteints de la TF, et elle requiert un traitement par des personnes dotées d'une expertise particulière. Le choix d'un traitement (pharmacologique, interventionnel ou les deux) pour soulager les symptômes, éviter les complications et réduire les risques dépend du type, de la sévérité et de la fréquence de l'arythmie, ainsi que des particularités de chaque tableau clinique. La prévention, la surveillance et la prise en charge de l'arythmie font partie intégrante des soins pour les patients atteints de la TF tout au long de leur vie, et elles sont cruciales pour optimiser les résultats cliniques.

4.
J Thromb Thrombolysis ; 51(4): 1090-1093, 2021 May.
Article in English | MEDLINE | ID: mdl-33165818

ABSTRACT

Long-term follow-up data of left atrial appendage (LAA) occlusion in patients with atrial fibrillation (AF) are sparse. To address these data gaps, we analysed the 4-year outcomes of AF patients following LAA occlusion. The was a retrospective cohort study of high-risk patients with AF who underwent successful implantation of the Amulet device at our center between 2014 and 2017. Study endpoints were the rate of stroke, major bleeding and all-cause mortality. We included 71 patients (35.2% females) with a median age of 78 (IQR 73-82) years. Over a median follow-up period of 46 (IQR 19-56) months, the annual rate of ischemic stroke was 1.06 events/100 patient-years (95% CI 0-2.35), hemorrhagic stroke was 1.06 events/100 patient-years (95% CI 0-2.35) and major extracranial bleeding that required unplanned hospital admission was 1.84 events/100 patient-years (95% CI 0.25-3.43). A total of 28 (39.4%) patients died during this period with an annual mortality rate of 10.29 events/100 patient-years (95% CI 7.25-13.32). Our experience suggests that LAA occlusion using the Amulet device appears to be associated with a low risk of ischemic stroke in high-risk AF patients who are deemed unsuitable for oral anticoagulation; however, these patients have a high rate of mortality over the medium to long-term follow-up, and an ongoing significant risk of bleeding and thrombotic events.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Ischemic Stroke , Stroke , Aged , Aged, 80 and over , Atrial Appendage/surgery , Atrial Fibrillation/complications , Cardiac Catheterization , Female , Follow-Up Studies , Hemorrhage , Humans , Male , Retrospective Studies , Stroke/etiology , Stroke/prevention & control , Treatment Outcome
5.
JACC Clin Electrophysiol ; 6(5): 574-582, 2020 05.
Article in English | MEDLINE | ID: mdl-32439044

ABSTRACT

OBJECTIVES: This study sought to assess long-term arrhythmic risk in patients with myocarditis who received an implantable cardioverter-defibrillator (ICD). BACKGROUND: The arrhythmic risk of patients with myocarditis overtime remains poorly known. METHODS: The study enrolled 56 patients with biopsy-proven myocarditis who received an ICD for either primary (57%) or secondary prevention (43%) according to current guidelines. Clinical characteristics, biopsy findings, electrophysiological data from endocardial 3-dimensional electroanatomic voltage mapping, and device interrogation data were analyzed to detect arrhythmic events overtime. Coronary angiography excluded significant coronary artery disease in all patients. RESULTS: At a mean follow-up of 74 ± 60 months (median 65 months), 25 (45%) patients had major ventricular arrhythmias treated by ICD intervention (76% being terminated by ICD shock and 24% by antitachyarrhythmia burst pacing). At multivariable analysis, the presence of sustained ventricular tachycardia on admission (hazard ratio: 13.0; 95% confidence interval: 2.0 to 35.0; p = 0.032) and the extension of the areas of low potentials at the bipolar endocardial mapping (hazard ratio: 1.19; 95% confidence interval: 1.04 to 1.37; p = 0.013) were the only independent predictors of appropriate ICD interventions. A cutoff value of 10% of abnormal bipolar area at electroanatomical ventricular mapping discriminated patients with appropriate ICD interventions with a sensitivity of 89% and a specificity of 85%. CONCLUSIONS: The study demonstrates that the prevalence of life-threatening ventricular arrhythmias in patients with myocarditis receiving an ICD according to current guidelines is high and the arrhythmic risk persists late overtime. Electroanatomical ventricular mapping may be a useful tool to identify patients at greater arrhythmic risk.


Subject(s)
Defibrillators, Implantable , Myocarditis , Tachycardia, Ventricular , Biopsy , Humans , Myocarditis/complications , Myocarditis/epidemiology , Risk Assessment , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology
8.
Europace ; 21(11): 1605-1606, 2019 11 01.
Article in English | MEDLINE | ID: mdl-31549162
9.
Pacing Clin Electrophysiol ; 42(11): 1448-1455, 2019 11.
Article in English | MEDLINE | ID: mdl-31538362

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) ablation is a complex procedure, generally requiring at least one overnight hospital stay. We investigated the safety and feasibility of early mobilization and same-day discharge following streamlined peri-ablation management for AF. METHODS: From 2014, we offered same-day discharge to selected patients who underwent uncomplicated AF ablation on the morning lists, with ultrasound-guided femoral access, uninterrupted warfarin or minimal interruption in novel oral anticoagulants, and reversal of intraprocedural heparin with protamine. Patients were discharged 6-8 h postprocedure and offered access to a dedicated nurse helpline. RESULTS: Of 1599 AF ablation cases performed from April 2014 to March 2017, 811 (50.7%) were performed on the morning lists and 169/811 (20.8%) were discharged on the same day. Excluding 26 research cases, 1/143 (0.7%) had transient right phrenic nerve palsy and five (3.5%) cases experienced minor problems that did not preclude same-day discharge; three (2.1%) needed rehospitalization postdischarge: one for pericarditic chest pain and two for nausea/vomiting. Compared to 642 overnight cases, day-case procedures were shorter, more likely to be redos, to be performed under sedation rather than general anesthesia, and less likely to involve linear lesions and electrical cardioversion. There were no significant differences in patient age, gender, body mass index, CHA2 DS2 -VASc, in preprocedural anticoagulation regimen (warfarin vs novel anticoagulants vs no anticoagulation) and in choice of ablation method (cryoballoon vs radiofrequency). CONCLUSIONS: Selective same-day discharge after AF ablation is safe and feasible using a streamlined peri-procedural care protocol. Wider adoption can potentially reduce health-care costs while improving patient experience.


Subject(s)
Ambulatory Surgical Procedures , Atrial Fibrillation/surgery , Catheter Ablation , Patient Discharge , Patient Selection , Aged , Catheter Ablation/adverse effects , Early Ambulation , Feasibility Studies , Female , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies , Time Factors
10.
Curr Cardiol Rep ; 21(9): 96, 2019 07 27.
Article in English | MEDLINE | ID: mdl-31352528

ABSTRACT

PURPOSE OF REVIEW: Electrical storm (ES) is a life-threatening medical emergency of repetitive episodes of sustained ventricular arrhythmias within a short period. Its occurrence is associated with poor short- and long-term survival, even in patients with implantable cardioverter defibrillators (ICD). Management of ES is challenging and mainly based on retrospective studies. This article reviews the existing literature on ES, presents the available data regarding its management, and proposes a new algorithm based on current evidence. RECENT FINDINGS: Recent research could modify the management of ES supporting the role of non-selective ß1 and ß2 blockade and the early intervention with catheter ablation as well as strengthening the role of cardiac sympathetic denervation. A multipronged approach should be considered for the management of ES including identification and correction of reversible causes, ICD reprogramming, drug therapy (beta-blockers-especially non-selective ones-and other anti-arrhythmic drugs) and non-pharmacologic therapies such as catheter ablation and techniques of neuroaxial modulation. Although current data suggest early aggressive management, further research is required to clarify the optimal order and combination of therapies for the prevention of future events.


Subject(s)
Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Adrenergic beta-Antagonists/therapeutic use , Algorithms , Anesthesia, Conduction , Anti-Arrhythmia Agents/therapeutic use , Catheter Ablation , Combined Modality Therapy , Denervation , Humans , Hypnotics and Sedatives/therapeutic use
12.
Int J Cardiol ; 277: 110-117, 2019 Feb 15.
Article in English | MEDLINE | ID: mdl-30196998

ABSTRACT

BACKGROUND: To investigate the long term outcomes after catheter ablation (CA) of ventricular tachycardia (VT) in the context of structural heart disease in a multicenter cohort. The impact of different ablation strategies (substrate ablation versus activation guided versus combined) and non-inducibility as an end-point was evaluated. METHODS: Data was pooled from prospective registries at 5 centres over a 5 year period. Success was defined as survival free from recurrent ventricular arrhythmias (VA). Multivariate analysis of factors predicting survival free from VA was analysed by Cox regression. RESULTS: Five hundred sixty-six patients underwent CA for VT. Patients were 64 ±â€¯15 years. Left ventricular ejection fraction was 35 ±â€¯15% and 66% had ischaemic heart disease. At 2.3 (IQR 1.0-4.2) years, success was achieved in 44% after a single procedure, rising to 60% after repeat procedures. Mortality at final follow up was 22%. Multivariate analysis showed that higher left ventricular ejection fraction, younger age, ischaemic heart disease, and non-inducibility of VA predicted long term survival free from VA (all p < 0.05). There was no impact of the approach to ablation. CONCLUSION: CA eliminates VT in a large proportion of patients long term. Ablation strategy did not impact outcome and hence substrate ablation is a reasonable initial strategy. Non-inducibility of VA predicted survival free from VA and may be worth pursuing as a procedural end-point.


Subject(s)
Catheter Ablation/trends , Endpoint Determination/trends , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Aged , Catheter Ablation/mortality , Cohort Studies , Endpoint Determination/mortality , Female , Follow-Up Studies , Humans , Male , Middle Aged , Mortality/trends , Prospective Studies , Registries , Tachycardia, Ventricular/mortality , Treatment Outcome
13.
Heart ; 104(7): 626, 2018 04.
Article in English | MEDLINE | ID: mdl-29535218
14.
Heart ; 104(7): 594-599, 2018 04.
Article in English | MEDLINE | ID: mdl-29122931

ABSTRACT

OBJECTIVE: Percutaneous left atrial appendage (LAA) occlusion can be an interventional alternative to oral anticoagulation for stroke prevention in patients with atrial fibrillation. METHODS: We delivered LAA occlusion therapy using a standardised approach to patient referral, multidisciplinary team assessment, implant criteria, imaging and follow-up. We analysed patient characteristics, efficacy and safety of the implant procedure, and 12-month outcomes. RESULTS: Of 143 referrals from October 2014 to December 2016, 83 patients (age 76±8years, 32.5% female, mean CHAD2S2-VASc score 4 ±1) were offered LAA occlusion. Eighty (95.3%) had previous major bleeding (intracranial in 59%). LAA occluder implantation with an Amulet device was successful in 82 (98.8%), with periprocedural major adverse events occurring in 5 (6.0%) patients (2 device embolisations including 1 death, 2 major bleeds). Cardiac imaging in 75 (94%) patients 2months following implant showed device-related thrombus in 1 case (1.3%) and minor (<5mm) device leaks in 13 (17.1%). Over a median 12-month follow-up, 3 (3.8%) ischaemic strokes, 2 (2.5%) haemorrhagic strokes and 5 (6.3%) major extracranial bleeds occurred. All-cause mortality was 10%, with most deaths (7, 87.5%) due to non-cardiovascular causes. CONCLUSIONS: LAA occlusion may be a reasonable option for stroke prevention inhigh-risk patients with atrial fibrillation ineligible for anticoagulation. However, procedural complication rates are not insignificant, and patients remain at risk of serious adverse events and death even after successful implant.


Subject(s)
Anticoagulants/adverse effects , Atrial Fibrillation/surgery , Hemorrhage/prevention & control , Postoperative Complications , Prosthesis Implantation , Septal Occluder Device/adverse effects , Stroke , Aged , Aged, 80 and over , Anticoagulants/administration & dosage , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/mortality , Echocardiography, Transesophageal/methods , Female , Hemorrhage/chemically induced , Humans , Male , Outcome and Process Assessment, Health Care , Postoperative Complications/classification , Postoperative Complications/diagnosis , Prosthesis Implantation/adverse effects , Prosthesis Implantation/methods , Risk Adjustment , Risk Assessment , Stroke/etiology , Stroke/prevention & control , United Kingdom
17.
J Am Coll Radiol ; 13(1): 55-8, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26482817

ABSTRACT

PURPOSE: To assess radiation dose in common pediatric diagnostic fluoroscopy procedures and determine the efficacy of dose tracking and dose reduction training to reduce radiation use. METHODS: Fluoroscopy time and radiation dose area product (DAP) were recorded for upper GIs (UGI), voiding cystourethrograms (VCUGs), and barium enemas (BEs) during a six-month period. The results were presented to radiologists followed by a 1-hour training session on radiation dose reduction methods. Data were recorded for an additional six months. DAP was normalized to fluoroscopy time, and Wilcoxon testing was used to assess for differences between groups. RESULTS: Data from 1,479 cases (945 pretraining and 530 post-training) from 9 radiologists were collected. No statistically significant difference was found in patient age, proportion of examination types, or fluoroscopy time between the pre- and post-training groups (P ≥ .1), with the exception of a small decrease in median fluoroscopy time for VCUGs (1.0 vs 0.9 minutes, P = .04). For all examination types, a statistically significant decrease was found in the median normalized DAP (P < .05) between pre- and post-training groups. The median (quartiles) for pretraining and post-training normalized DAPs (µGy·m(2) per minute) were 14.36 (5.00, 38.95) and 6.67 (2.67, 17.09) for UGIs; 13.00 (5.34, 32.71) and 7.16 (2.73, 19.85) for VCUGs; and 33.14 (9.80, 85.26) and 17.55 (7.96, 46.31) for BEs. CONCLUSIONS: Radiation dose tracking with feedback, paired with dose reduction training, can reduce radiation dose during diagnostic pediatric fluoroscopic procedures by nearly 50%.


Subject(s)
Fluoroscopy , Pediatrics/education , Radiation Dosage , Radiation Protection/methods , Radiology/education , Humans , Inservice Training , Time Factors
18.
J Cardiovasc Med (Hagerstown) ; 17(6): 425-32, 2016 Jun.
Article in English | MEDLINE | ID: mdl-25943625

ABSTRACT

AIMS: Electrical storm is an emergency in 'implantation of a cardioverter defibrillator' carriers with ischemic dilated cardiomyopathy (DCM) and negatively impacts long-term prognosis. We evaluated the feasibility, safety, and effectiveness of radiofrequency catheter ablation (RFCA) in controlling electrical storm and its impact on survival and ventricular tachycardia/fibrillation recurrence. METHODS: We enrolled 27 consecutive patients (25 men, age 73.1 ±â€Š6.5 years) with ischemic DCM and an indication to RFCA for drug-refractory electrical storm. The immediate outcome was defined as failure or success, depending on whether the patient's clinical ventricular tachycardia could still be induced after RFCA; electrical storm resolution was defined as no sustained ventricular tachycardia/ventricular fibrillation in the next 7 days. RESULTS: Of the 27 patients, 1 died before RFCA; in the remaining 26 patients, a total of 33 RFCAs were performed. In all 26 patients, RFCA was successful, although in 6/26 patients (23.1%), repeated procedures were needed, including epicardial ablation in 3/26 (11.5%). In 23/26 patients (88.5%), electrical storm resolution was achieved. At a follow-up of 16.7 ±â€Š8.1 months, 5/26 patients (19.2%) had died (3 nonsudden cardiac deaths, 2 noncardiac deaths) and 10/26 patients (38.5%) had ventricular tachycardia recurrence; none had electrical storm recurrence. A worse long-term outcome was associated with lower glomerular filtration rate, wider baseline QRS, and presence of atrial fibrillation before electrical storm onset. CONCLUSION: In patients with ischemic DCM, RFCA is well tolerated, feasible and effective in the acute management of drug-refractory electrical storm. It is associated with a high rate of absence of sustained ventricular tachycardia episodes over the subsequent 7 days. After successful ablation, long-term outcome was mainly predicted by baseline clinical variables.


Subject(s)
Cardiomyopathy, Dilated/therapy , Catheter Ablation/methods , Defibrillators, Implantable/adverse effects , Tachycardia, Ventricular/surgery , Ventricular Fibrillation/surgery , Aged , Catheter Ablation/adverse effects , Electrocardiography , Feasibility Studies , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Prognosis , Prospective Studies , Prosthesis Implantation/adverse effects , Prosthesis Implantation/methods , Tachycardia, Ventricular/etiology , Treatment Outcome , Ventricular Fibrillation/etiology
19.
Heart Rhythm ; 10(12): 1850-8, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24055940

ABSTRACT

BACKGROUND: Advanced techniques of electroanatomical mapping efficiently guide ventricular tachycardia (VT) ablation strategies; in this context, the adjunctive value of combining activation mapping (AMap) to improve accuracy has not been elucidated. OBJECTIVE: To investigate whether conventional AMap further contributes to the identification of critical sites of VT reentry and whether this translates into a more effective ablation outcome in a cohort of patients undergoing VT ablation. METHODS: We prospectively enrolled 126 patients (mean age 65.3 ± 10.5 years; left ventricular ejection fraction 33.3% ± 7.2%) with ischemic (n = 89) or idiopathic (n = 37) dilated cardiomyopathy undergoing endocardial (n = 105) or endo-epicardial (n = 21) electroanatomical mapping and ablation. A substrate-guided strategy targeting surrogate markers of reentry was accomplished in all patients, but the feasibility and efficacy of AMap was preliminarily assessed for all induced VTs focusing on early VT suppression obtained during radiofrequency delivery. VT-free survival was assessed by ICD interrogation. RESULTS: AMap successfully guided ablation in 62 of 104 (59.6%) patients with inducible VT(s). At 1 year, 6 of 126 (4.8%) patients died; VT recurred in 28 of 126 (22.2%) patients. No significant difference in VT recurrence rate was observed between patients in whom AMap proved effective versus those in whom substrate-guided ablation was not corroborated by AMap (16 of 62 [25.8%] vs 12 of 64 [18.8%]; log-rank test, P = .3). CONCLUSIONS: Our findings support the efficacy of a substrate-guided strategy targeting specific markers of arrhythmogenicity identified during sinus rhythm. AMap proves highly efficient acutely but does not improve overall VT-free survival, suggesting that in patients with advanced cardiac disease, life-threatening arrhythmias can be successfully treated by ablation in sinus rhythm, thus limiting procedural risks.


Subject(s)
Body Surface Potential Mapping/methods , Catheter Ablation/instrumentation , Tachycardia, Ventricular/surgery , Aged , Equipment Design , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Stroke Volume , Tachycardia, Ventricular/physiopathology , Treatment Outcome
20.
Can J Cardiol ; 29(11): 1532.e11-3, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23809539

ABSTRACT

We discuss a case of transvenous lead extraction (TLE) in a patient with a large vegetation. To prevent embolization, a Dormia basket was placed in the pulmonary artery trunk. After uncomplicated TLE, the basket was withdrawn, and vegetation material was retrieved from it. Our experience confirms that TLE is feasible even with large vegetations, and the pulmonary circulation may be protected with a simple intravascular device.


Subject(s)
Defibrillators, Implantable/adverse effects , Device Removal/instrumentation , Embolism/prevention & control , Prosthesis-Related Infections/surgery , Ultrasonography, Interventional , Aged, 80 and over , Echocardiography, Transesophageal , Humans , Male , Pulmonary Artery
SELECTION OF CITATIONS
SEARCH DETAIL
...