Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Ophthalmol ; : 11206721231217127, 2023 Dec 15.
Article in English | MEDLINE | ID: mdl-38099841

ABSTRACT

PURPOSE: To report the outcomes of standardizing pre-loaded DMEK with endothelium-inwards and its associated learning curve. METHODS: Between 2017 and 2021, a total of 599 tissues were stripped using 'trephine and strip' method and loaded by folding the tissue as a taco-fold with endothelium-inwards. The folded tissues were pulled inside the funnel of a 2.2 mm IOL cartridge and stored for the desired number of days in organ culture media supplemented with dextran. Donor characteristics, endothelial cell loss (ECL) and mortality assessed by trypan blue positivity before and after stripping, and eventful cases during stripping/loading were recorded. RESULTS: The tissues found unsuitable for transplant after stripping (6.7%) were significantly higher compared with loading (0.67%). Central or peripheral tears, fragility of the tissues, and insufficient endothelial cell density mainly attributed towards the discard rate. Mean ECL from pre-stripping to post-stripping was 0.27% with endothelial cell mortality of 0.64% at the end of stripping. Cumulative endothelial mortality fold change (pre-strip to post-strip) was high in the first two years of operation (18.9%), which reduced to 5.1% in the following three years with significant difference (p = 0.0352). Average tissue wastage (3 operators) from first 1-150 tissues was 3%, which significantly reduced to 0.9% after achieving the learning curve (151-250) (p = 0.0492). CONCLUSION: DMEK graft preparation requires a learning curve. However, an operator with DMEK stripping skills can easily adapt to pre-loading a DMEK graft in endothelium-inwards fashion with minimal learning curve.

2.
Cornea ; 40(6): 786-789, 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-33214417

ABSTRACT

PURPOSE: To report the management of precut Descemet stripping automated endothelial keratoplasty (DSAEK) lenticules unsuitable for transplantation because of irregular anterior profile after microkeratome cutting. METHODS: After preparation for DSAEK, 20 tissues were considered unsuitable for transplantation because of nonhomogeneous posterior stromal thickness. To convert them into suitable tissues for surgery, manual stromal delamination was performed by removing the excess stromal layers after the indications obtained through optical coherence tomography. These tissues were further transplanted as ultrathin DSAEK. RESULTS: Nineteen tissues were delaminated successfully. The average reduction in thickness in the center (63 ± 69 µm; P = 0.0101) and periphery (129 ± 39 µm; P < 0.0001) before and after delamination was significantly different. One tissue showed signs of perforation during manual dissection and therefore considered unsuitable for transplantation. Primary graft failure was reported in one case, but it was not correlated with the tissue preparation. No other clinical complications were observed after surgery. CONCLUSIONS: Manual delamination of the stroma because of irregular microkeratome cutting is a viable option to obtain a uniform graft thickness required for DSAEK surgeries. This technique can further reduce tissue wastage that is observed after microkeratome cutting errors.


Subject(s)
Corneal Stroma/surgery , Descemet Stripping Endothelial Keratoplasty/methods , Eye Banks/methods , Aged , Cell Count , Corneal Stroma/diagnostic imaging , Endothelium, Corneal/transplantation , Female , Humans , Male , Middle Aged , Tissue Donors , Tissue and Organ Harvesting , Tomography, Optical Coherence
3.
Cornea ; 37(6): 767-771, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29498968

ABSTRACT

PURPOSE: To investigate the learning curve of Descemet membrane endothelial keratoplasty (DMEK) graft preparation in an eye bank. METHODS: Four operators prepared 645 DMEK grafts using the stripping technique between 2014 and 2017 at the Veneto Eye Bank Foundation, Italy. Endothelial cell loss (ECL) and tissue wastage were recorded retrospectively after DMEK preparation and correlated with the number of tissues prepared each year by each operator. On average, our operators performed 1 donor preparation a week over the course of this study. Only donors older than 60 years were used in this study, and approximately 10% of donors had diabetes. The Wilcoxon test for paired data and 1-way ANOVA were used for checking statistical significance with the Tukey test as post hoc analysis. P < 0.05 was considered statistically significant. RESULTS: ECL did not change significantly over time from operator 1. Significant ECL drop was noted from operator 2 between years 2014-2016 (P = 0.0049) and 2017 (P = 0.0094); from operator 3 between years 2015-2016 (P = 0.0288) and 2017 (P = 0.0097); and from operator 4 between 2015-2016 (P = 0.0469) and 2017 (P = 0.0331). Operators 1 and 3 did not show a significant difference, considering every 50 grafts prepared by each operator. Operator 2 showed significant ECL drop between 1 to 50 and 51 to 100 (P = 0.0002) and 1 to 50 and 101 to 150 (P = 0.0001) grafts. Operator 4 showed significant ECL drop between 1 to 50 and 101 to 150 (P = 0.002) and 51 to 100 and 101 to 141 (P = 0.0207) grafts. No intraoperator difference was observed per 50 grafts (P > 0.05). CONCLUSIONS: There is a learning curve for DMEK graft preparation. ECL and tissue wastage can be reduced with practice and skills. However, each operator may be limited to his or her own learning capability.


Subject(s)
Descemet Membrane/surgery , Descemet Stripping Endothelial Keratoplasty/methods , Endothelium, Corneal/transplantation , Eye Banks/statistics & numerical data , Tissue and Organ Harvesting/methods , Aged , Analysis of Variance , Corneal Endothelial Cell Loss/pathology , Eye Banks/methods , Female , Humans , Learning Curve , Middle Aged , Retrospective Studies , Tissue and Organ Harvesting/standards
4.
Cornea ; 36(12): 1458-1466, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28968293

ABSTRACT

PURPOSE: To share the experience and provide a standardized protocol for Descemet membrane endothelial keratoplasty (DMEK) graft preparation. METHODS: A retrospective study based on 527 prestripped DMEK tissues that were prepared between 2014 and 2017. The experience of using different instruments and techniques has been described, and a standardized technique for preparing DMEK grafts has been identified. The tissues in general were prepared by superficially tapping the endothelial side with a Moria trephine (9.5 mm diameter). The plane of cleavage was identified using a cleavage hook, and the DMEK graft was deadhered from the trephined site throughout the circumference for ease of excising the graft. The DMEK graft was peeled using either one or multiple quadrant methods depending on the challenges faced during excision. The graft was finally marked with the letter "F" to identify the orientation during surgery. Data on endothelial cell loss (ECL) and challenging cases were observed, monitored, and recorded during this period. RESULTS: Less than 1 percent trypan blue-positive cells with tissue wastage of <6% was observed during the study period. Our standardized stripping technique has resulted in an overall ECL of 4.6%. Marking Descemet membrane showed 0.5% cell mortality. CONCLUSIONS: Standardizing DMEK technique using specific tools and simple techniques would help new surgeons to decide the instruments and improve their tissue preparation skills also in challenging cases such as previous cataract incisions or horseshoe-shaped tears, further reducing ECL or tissue wastage.


Subject(s)
Descemet Membrane/surgery , Descemet Stripping Endothelial Keratoplasty/methods , Endothelium, Corneal/transplantation , Eye Banks/methods , Tissue and Organ Harvesting/methods , Female , Humans , Male , Retrospective Studies , Tissue and Organ Harvesting/instrumentation
5.
Patient Educ Couns ; 99(6): 878-87, 2016 06.
Article in English | MEDLINE | ID: mdl-26898599

ABSTRACT

OBJECTIVE: the article analyzes how a doctor delivers diagnoses and recommends treatment in a set of post-surgical oncological visits. The pattern of activities are explored in two different cases: when all diagnostic information is available, and when information is still missing. METHODS: The data consist of 12 video-recorded visits of breast cancer patients to a senior oncologist. Conversation analysis is employed to analyze sequences in which the delivery of diagnosis and treatment recommendation unfold. RESULTS: The oncologist formulates the treatment recommendation as a logical consequence deriving from the available diagnostic information. In cases when definitive diagnostic information on the cancer type is missing, the oncologist opts to anticipate hypothetical diagnostic scenarios, and to draw the therapeutic alternatives as logical outcomes envisionable from each of the different scenarios. CONCLUSION: The communicative practice appears functional to encourage the patients' acceptance of a single treatment option rather than present the patients to and involve them in deliberating over multiple available treatment alternatives. PRACTICE IMPLICATIONS: Rather than a normative adoption of existing protocols of communication in cancer care, a better understanding of communication practices in use can help practitioners to reflect upon and make intentional choices about different arrangements for the patient's participation.


Subject(s)
Breast Neoplasms/psychology , Breast Neoplasms/surgery , Communication , Decision Making , Patient Participation , Physician-Patient Relations , Adult , Female , Humans , Middle Aged , Office Visits , Physicians , Postoperative Care , Practice Patterns, Physicians' , Video Recording
6.
Toxicol In Vitro ; 29(7): 1619-27, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26100225

ABSTRACT

A superfusion apparatus (SA) was developed to maintain isolated human corneas ex vivo under conditions which mimic the natural eye environment in vivo, including controlled temperature, tear flow and intraocular pressure. The SA was designed, developed and tested for use in ophthalmic pre-clinical research and to test new pharmaceutical formulations. Corneas undergo an equilibration process in the new physiological environment for one day. The test was then initiated by the application of the test substance, incubation, and temporal assessment of corneal damage using various parameters. The effects of mild and severe irritant concentrations of NaOH (2% and 8%, respectively) on corneal opacity, swelling and epithelial integrity were studied, and the inflammatory status assessed using F4/80 and MPO as macrophages and neutrophils markers, respectively. The SA was then used to test new artificial tear formulations supplemented with silver ions as an active constituent, showing different degrees of inflammatory responses as indicated by the migration of MPO and F4/80 positive cells towards the epithelium. The human cornea superfusion apparatus was proposed as a model for acute eye irritation research.


Subject(s)
Animal Testing Alternatives , Caustics/toxicity , Cornea/drug effects , Irritants/toxicity , Sodium Hydroxide/toxicity , Antigens, Differentiation/metabolism , Ascorbic Acid/toxicity , Cornea/pathology , Corneal Opacity , Humans , In Vitro Techniques , Lubricant Eye Drops/toxicity , Ophthalmic Solutions , Peroxidase/metabolism , Silver Nitrate/toxicity
SELECTION OF CITATIONS
SEARCH DETAIL
...