Int Endod J ; 50(5): 499-505, 2017 May.
Article in English | MEDLINE | ID: mdl-27037801

ABSTRACT

AIM: To evaluate the percentage volumes of filling materials and voids in single-rooted teeth filled with three different filling systems using micro-computed tomography (micro-CT). METHODOLOGY: Thirty single-rooted human teeth were used. After preparation of the root canals, the teeth were randomly divided into three groups (n = 10). The canals were filled with EndoREZ, ActiV GP or AH Plus/gutta-percha. Each specimen was scanned using a micro-CT device at a resolution of 13.68 µm. Percentage volumes of root filling materials and voids were calculated and data were analysed statistically using the Kruskal-Wallis test and the Mann-Whitney U-test with Bonferroni adjustment. Within each group, the Friedman test was performed with the Wilcoxon signed-rank test to detect discrepancies. RESULTS: The percentage volume of filling material was significantly lower in the ActiV GP group than in the other groups (P < 0.05), whilst the percentage volume of voids was significantly higher in the ActiV GP group than in the other groups (P < 0.05). CONCLUSION: None of the systems were associated with void-free root fillings. The ActiV GP system had a significantly higher percentage volume of voids than the other systems.


Subject(s)
Root Canal Filling Materials/standards , X-Ray Microtomography , Acrylic Resins , Composite Resins , Epoxy Resins , Humans , In Vitro Techniques