Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 12(1): 11076, 2022 Jun 30.
Article in English | MEDLINE | ID: mdl-35773293

ABSTRACT

For effective cutting tool inserts that absorb thermal shock at varying temperature gradients, improved thermal conductivity and toughness are required. In addition, parameters such as the coefficient of thermal expansion must be kept within a reasonable range. This work presents a novel material design framework based on a multi-scale modeling approach that proposes nickel (Ni)-reinforced alumina (Al2O3) composites to tailor the mechanical and thermal properties required for ceramic cutting tools by considering numerous composite parameters. The representative volume elements (RVEs) are generated using the DREAM.3D software program and the output is imported into a commercial finite element software ABAQUS. The RVEs which contain multiple Ni particles with varying porosity and volume fractions are used to predict the effective thermal and mechanical properties using the computational homogenization methods under appropriate boundary conditions (BCs). The RVE framework is validated by the sintering of Al2O3-Ni composites in various compositions. The predicted numerical results agree well with the measured thermal and structural properties. The properties predicted by the numerical model are comparable with those obtained using the rules of mixtures and SwiftComp, as well as the Fast Fourier Transform (FFT) based computational homogenization method. The results show that the ABAQUS, SwiftComp and FFT results are fairly close to each other. The effects of porosity and Ni volume fraction on the mechanical and thermal properties are also investigated. It is observed that the mechanical properties and thermal conductivities decrease with the porosity, while the thermal expansion remains unaffected. The proposed integrated modeling and empirical approach could facilitate the development of unique Al2O3-metal composites with the desired thermal and mechanical properties for ceramic cutting inserts.

2.
Mater Sci Eng C Mater Biol Appl ; 118: 111228, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33254956

ABSTRACT

Organ repair, regeneration, and transplantation are constantly in demand due to various acute, chronic, congenital, and infectious diseases. Apart from traditional remedies, tissue engineering (TE) is among the most effective methods for the repair of damaged tissues via merging the cells, growth factors, and scaffolds. With regards to TE scaffold fabrication technology, polyurethane (PU), a high-performance medical grade synthetic polymer and bioactive material has gained significant attention. PU possesses exclusive biocompatibility, biodegradability, and modifiable chemical, mechanical and thermal properties, owing to its unique structure-properties relationship. During the past few decades, PU TE scaffold bioactive properties have been incorporated or enhanced with biodegradable, electroactive, surface-functionalised, ayurvedic products, ceramics, glass, growth factors, metals, and natural polymers, resulting in the formation of modified polyurethanes (MPUs). This review focuses on the recent advances of PU/MPU scaffolds, especially on the biomedical applications in soft and hard tissue engineering and regenerative medicine. The scientific issues with regards to the PU/MPU scaffolds, such as biodegradation, electroactivity, surface functionalisation, and incorporation of active moieties are also highlighted along with some suggestions for future work.


Subject(s)
Polyurethanes , Tissue Engineering , Biocompatible Materials/pharmacology , Polymers , Tissue Scaffolds
3.
Colloids Surf B Biointerfaces ; 176: 80-86, 2019 Apr 01.
Article in English | MEDLINE | ID: mdl-30594706

ABSTRACT

A metal-inorganic composite, comprises of silver-molybdenum disulfide nanosheets (Ag@MoS2) was synthesized at low temperature. The Ag@MoS2 composite was drop-casted onto a glassy carbon electrode (GCE) for a highly selective dopamine (DA) detection in the presence of interfering compounds such as uric acid (UA) and ascorbic acid (AA). The physicochemical analysis of the nanosheets was carried out with X-ray diffraction, transmission electron microscopy and X-ray photoelectron spectroscopy. The as-prepared Ag@MoS2-modified GCE displayed excellent electrocatalytic activity toward DA oxidation, with a 0.2 µM detection limit at a signal-to-noise ratio of 3 and an extensive linear detection range from 1 µM to 500 µM (R2 = 0.9983). The fabricated non-enzymatic electrochemical sensor demonstrated superior selectivity and stability for the detection of DA with the removal of AA and UA interfering compounds.


Subject(s)
Disulfides/chemistry , Dopamine/analysis , Metal Nanoparticles/chemistry , Molybdenum/chemistry , Nanoparticles/chemistry , Silver/chemistry , Disulfides/chemical synthesis , Electrodes , Particle Size , Surface Properties
4.
J Biomed Mater Res A ; 105(11): 3197-3223, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28686004

ABSTRACT

Bioglass® 45S5 (BG) has an outstanding ability to bond with bones and soft tissues, but its application as a load-bearing scaffold material is restricted due to its inherent brittleness. BG-based composites combine the amazing biological and bioactive characteristics of BG with structural and functional features of other materials. This article reviews the composites of Bioglass® in combination with metals, ceramics and polymers for a wide range of potential applications from bone scaffolds to nerve regeneration. Bioglass® also possesses angiogenic and antibacterial properties in addition to its very high bioactivity; hence, composite materials developed for these applications are also discussed. BG-based composites with polymer matrices have been developed for a wide variety of soft tissue engineering. This review focuses on the research that suggests the suitability of BG-based composites as a scaffold material for hard and soft tissues engineering. Composite production techniques have a direct influence on the bioactivity and mechanical behavior of scaffolds. A detailed discussion of the bioactivity, in vitro and in vivo biocompatibility and biodegradation is presented as a function of materials and its processing techniques. Finally, an outlook for future research is also proposed. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 3197-3223, 2017.


Subject(s)
Biocompatible Materials/chemistry , Ceramics/chemistry , Glass/chemistry , Tissue Engineering/methods , Animals , Biocompatible Materials/metabolism , Bone Regeneration , Ceramics/metabolism , Humans , Materials Testing , Metals/chemistry , Metals/metabolism , Nanostructures/chemistry , Polymers/chemistry , Polymers/metabolism , Tissue Scaffolds/chemistry
5.
J Mech Behav Biomed Mater ; 69: 1-18, 2017 05.
Article in English | MEDLINE | ID: mdl-28027481

ABSTRACT

Recently, the robust optimization and prediction models have been highly noticed in district of surface engineering and coating techniques to obtain the highest possible output values through least trial and error experiments. Besides, due to necessity of finding the optimum value of dependent variables, the multi-objective metaheuristic models have been proposed to optimize various processes. Herein, oriented mixed oxide nanotubular arrays were grown on Ti-6Al-7Nb (Ti67) implant using physical vapor deposition magnetron sputtering (PVDMS) designed by Taguchi and following electrochemical anodization. The obtained adhesion strength and hardness of Ti67/Nb were modeled by particle swarm optimization (PSO) to predict the outputs performance. According to developed models, multi-objective PSO (MOPSO) run aimed at finding PVDMS inputs to maximize current outputs simultaneously. The provided sputtering parameters were applied as validation experiment and resulted in higher adhesion strength and hardness of interfaced layer with Ti67. The as-deposited Nb layer before and after optimization were anodized in fluoride-base electrolyte for 300min. To crystallize the coatings, the anodically grown mixed oxide TiO2-Nb2O5-Al2O3 nanotubes were annealed at 440°C for 30min. From the FESEM observations, the optimized adhesive Nb interlayer led to further homogeneity of mixed nanotube arrays. As a result of this surface modification, the anodized sample after annealing showed the highest mechanical, tribological, corrosion resistant and in-vitro bioactivity properties, where a thick bone-like apatite layer was formed on the mixed oxide nanotubes surface within 10 days immersion in simulated body fluid (SBF) after applied MOPSO. The novel results of this study can be effective in optimizing a variety of the surface properties of the nanostructured implants.


Subject(s)
Biocompatible Materials/analysis , Materials Testing , Nanotubes/analysis , Titanium/analysis , Body Fluids , Corrosion , Oxides , Surface Properties
6.
Biosens Bioelectron ; 90: 125-139, 2017 Apr 15.
Article in English | MEDLINE | ID: mdl-27886599

ABSTRACT

The presence of heavy metal in food chains due to the rapid industrialization poses a serious threat on the environment. Therefore, detection and monitoring of heavy metals contamination are gaining more attention nowadays. However, the current analytical methods (based on spectroscopy) for the detection of heavy metal contamination are often very expensive, tedious and can only be handled by trained personnel. DNA biosensors, which are based on electrochemical transduction, is a sensitive but inexpensive method of detection. The principles, sensitivity, selectivity and challenges of electrochemical biosensors are discussed in this review. This review also highlights the major advances of DNA-based electrochemical biosensors for the detection of heavy metal ions such as Hg2+, Ag+, Cu2+ and Pb2+.


Subject(s)
Biosensing Techniques/methods , DNA/chemistry , Ions/isolation & purification , Metals, Heavy/isolation & purification , Environmental Monitoring , G-Quadruplexes , Gold/isolation & purification , Gold/toxicity , Ions/toxicity , Mercury/isolation & purification , Mercury/toxicity , Metals, Heavy/toxicity
7.
Mater Sci Eng C Mater Biol Appl ; 59: 500-508, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26652401

ABSTRACT

The present study examines the synthesis of Co3O4 ultra-nanosheets (Co3O4 UNSs) and Co3O4 ultra-nanosheet-Ni(OH)2 (Co3O4 UNS-Ni(OH)2) via solvothermal process and their application as non-enzymatic electrochemical sensors for glucose detection. X-ray diffraction and transmission electron microscopy results confirmed the Co3O4 UNS deposition on Ni(OH)2 surface. The presence of Co3O4 UNSs on Ni (OH) 2 surface improved the sensitivity of glucose detection, from the increase of glucose oxidation peak current at the Co3O4 UNS-Ni(OH)2/glassy carbon electrode (current density: 2000µA·cm(-2)), compared to the Co3O4 UNSs. These results confirmed that Ni(OH)2 on glassy carbon electrode is a sensitive material for glucose detection, moreover the Co3O4 UNSs can increase the interaction and detection of glucose due to their high surface area. The estimated limit of detection (S/N=3) and limit of quantification (S/N=10) of the linear segment (5-40µM) are 1.08µM and 3.60µM respectively. The reproducibility experiments confirmed the feasibility of Co3O4 UNS-Ni(OH)2 for the quantitative detection of certain concentration ranges of glucose.


Subject(s)
Cobalt/chemistry , Glucose/analysis , Hydroxides/chemistry , Membranes, Artificial , Nanostructures/chemistry , Nickel/chemistry , Oxides/chemistry
8.
Mater Sci Eng C Mater Biol Appl ; 49: 656-668, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25686995

ABSTRACT

The effect of the addition of an ionic dopant to calcium phosphates for biomedical applications requires specific research due to the essential roles played in such processes. In the present study, the mechanical and biological properties of Ni-doped hydroxyapatite (HA) and Ni-doped HA mixed with graphene nanoplatelets (GNPs) were evaluated. Ni (3wt.% and 6wt.%)-doped HA was synthesized using a continuous precipitation method and calcined at 900°C for 1h. The GNP (0.5-2wt.%)-reinforced 6% Ni-doped HA (Ni6) composite was prepared using rotary ball milling for 15h. The sintering process was performed using hot isostatic pressing at processing conditions of 1150°C and 160MPa with a 1-h holding time. The results indicated that the phase compositions and structural features of the products were noticeably affected by the Ni and GNPs. The mechanical properties of Ni6 and 1.5Ni6 were increased by 55% and 75% in hardness, 59% and 163% in fracture toughness and 120% and 85% in elastic modulus compared with monolithic HA, respectively. The in-vitro biological behavior was investigated using h-FOB osteoblast cells in 1, 3 and 5days of culture. Based on the osteoblast results, the cytotoxicity of the products was indeed affected by the Ni doping. In addition, the effect of GNPs on the growth and proliferation of osteoblast cells was investigated in Ni6 composites containing different ratios of GNPs, where 1.5wt.% was the optimum value.


Subject(s)
Biocompatible Materials/chemistry , Calcium Phosphates/chemistry , Graphite/chemistry , Nanocomposites/chemistry , Nickel/chemistry , Biocompatible Materials/pharmacology , Calcium Phosphates/pharmacology , Cells, Cultured , Durapatite/chemistry , Durapatite/pharmacology , Elastic Modulus/drug effects , Graphite/pharmacology , Hardness , Humans , Hydroxyapatites/chemistry , Materials Testing/methods , Nickel/pharmacology , Osteoblasts/drug effects , Pressure , Surface Properties
9.
J Mech Behav Biomed Mater ; 20: 272-82, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23453827

ABSTRACT

In this study, titanium thin films were deposited on alumina substrates by radio frequency (RF) magnetron sputtering. The mechanical properties of the Ti coatings were evaluated in terms of adhesion strength at various RF powers, temperatures, and substrate bias voltages. The coating conditions of 400W of RF power, 250°C, and a 75V substrate bias voltage produced the strongest coating adhesion, as obtained by the Taguchi optimisation method. TiO2 nanotube arrays were grown as a second layer on the Ti substrates using electrochemical anodisation at a constant potential of 20V and anodisation times of 15min, 45min, and 75min in a NH4F electrolyte solution (75 ethylene glycol: 25 water). The anodised titanium was annealed at 450°C and 650°C in a N2 gas furnace to obtain different phases of titania, anatase and rutile, respectively. The mechanical properties of the anodised layer were investigated by nanoindentation. The results indicate that Young's modulus and hardness increased with annealing temperature to 650°C.


Subject(s)
Aluminum Oxide/chemistry , Coated Materials, Biocompatible/chemistry , Nanotubes/chemistry , Nanotubes/ultrastructure , Titanium/chemistry , Compressive Strength , Crystallization/methods , Elastic Modulus , Hardness , Materials Testing , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL
...