Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Cureus ; 15(9): e44816, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37809176

ABSTRACT

AIM: To evaluate microspace and microleakage between implant and abutments subjected to pre- and post-calibrated cyclic stress. MATERIALS AND METHODS: Twelve screw-retained implant prostheses with BioHPP polyetheretherketone (PEEK) abutment (Noris Dental Implant System Ltd., Nesher, Israel) (Group I) and 12 screw-retained implant prostheses with computer-assisted design/computer-assisted manufacturing (CAD/CAM) milled zirconia abutment (DentGallop, Houston, TX, USA) (Group II) were connected to their respective implant, and the prosthetic screw was torqued to 30N/cm (Noris). The microspace was evaluated using scanning electron microscopy (SEM; TeScan, Brno, Czech Republic). Twenty-four samples were then induced to cyclic stress (Lokesh Industries, Pune, India) simulating 180 days duration of oral stress. The microspaces (Group IA and Group IIB) were measured post-cyclic stress. Group I and II were again renamed into Group Ia and Group IIb for microbial study. Both implant assemblies were immersed in fresh soybean casein digest broth (SCDB) (Himedia, Mumbai, India) and subsequently inoculated with 1.0µL E. coli suspension (Himedia) at the open end and incubated at 37ºC for seven days. After the incubation period, cellular activity was determined by the spread plate method, and total colony-forming units (CFU) were calculated. The results were evaluated using independent T and Mann-Whitney tests. RESULT: Average and microspace at the implant-abutment junction of Group I samples in the front right was 12.98µm, center 13.76µm, front left 13.22µm, and in Group II samples, the front right was 18.52µm, center 17.84µm, front left 18.58µm.After being subjected to cyclic loading, the mean levels of the vertical microgap for Group IA samples were: in the front right region 10.37µm, in the center 9.34µm, in the front left 10.51µm and in Group IIB samples front right was 14.59µm, center 13.39µm, front left 13.8µm. Independent t-tests showed insignificant differences between the two groups. The median value of microbial leakage of Group Ia samples after cyclic loading was 30 x 103 CFU/ml, and Group IIb samples were 42 x 103 CFU/ml and were significant. CONCLUSION: There was minimal variation in the mean microspace between the BioHPP PEEK abutment and CAD/CAM milled zirconia abutment, and it was insignificant before and after cyclic stress. BioHPP PEEK abutment-titanium implant interfaces showed significantly decreased microbial leakage than CAD/CAM milled zirconia abutment-titanium implant interfaces after cyclic stress.

2.
Cureus ; 15(5): e38654, 2023 May.
Article in English | MEDLINE | ID: mdl-37288238

ABSTRACT

Immediate implant placement is well-known science and treatment in implant dentistry. It is a multitasking treatment consisting of surgical, prosthodontic, and periodontal aspects, implemented to obtain long-term clinically esthetic and functioning prosthesis. Immediate placement enables clinicians to reduce the number of surgical steps and shorter treatment duration. It has become a standard surgical protocol in modern implant practice. According to existing literature, dual implant placement can be done to avoid any cantilever effect in a single implant and to distribute masticatory forces. This clinical report describes the extraction of an infected mandibular right first molar, (46, Federation Dentaire Internationale) followed by immediate dual placement of dental implants in the rinsed and cleansed sockets. The tooth was atraumatically extracted from the socket, and the latter was prepared to the required depth, and endosseous implants were placed in both the mesial and distal sockets. This atraumatic graft-free operating technique and immediate placement resulted in the preservation of hard and soft tissues. It also increased the patient's comfort, acceptance, and satisfaction due to immediate loading with a provisional removable prosthesis. This was later replaced with a dual screw-retained hybrid implant crown.

3.
J Indian Soc Periodontol ; 20(4): 468-471, 2016.
Article in English | MEDLINE | ID: mdl-28298833

ABSTRACT

The posterior maxillary segment frequently exhibits insufficient bone mass to support dental implants. Sinus floor augmentation enables implant placement in the posterior maxilla. This case series included ten sites, in which sinus floor elevation was done using sinus lift balloon system followed by augmentation utilizing irradiated cancellous bone allograft. Postoperative radiographic assessment of vertical bone gain was done at 3 and 6 months follow-up period. The mean initial and final bone height were 6.16 and 10.50 mm, respectively, with a mean increase of 4.34 mm at 6 months being observed with nil complication. The presented technique might represent a viable alternative for sinus elevation in posterior atrophied maxilla. Irradiated cancellous bone allograft can be advocated as an ideal bone graft material for sinus augmentation procedures.

SELECTION OF CITATIONS
SEARCH DETAIL
...