Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
J Sep Sci ; 38(10): 1642-8, 2015 May.
Article in English | MEDLINE | ID: mdl-25735884

ABSTRACT

This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods--the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification.

2.
Talanta ; 134: 402-408, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25618686

ABSTRACT

The selection of two high performance liquid chromatography (HPLC) columns with vastly different retention mechanisms is vital for performing effective two-dimensional (2D-) HPLC. This paper reports on a systematic method to select a pair of HPLC columns that provide the most different separations for a given sample. This was completed with the aid of a HPLC simulator that predicted retention profiles on the basis of real experimental data, which is difficult when the contents of sample matrices are largely-or completely-unknown. Peaks from the same compounds must first be matched between chromatograms to compare the retention profiles and optimised 2D-HPLC column selection. In this work, two methods of matching peaks between chromatograms were explored and an optimal pair of chromatography columns was selected for 2D-HPLC. First, a series of 17 antioxidants were selected as an analogue for a coffee extract. The predicted orthogonality of the standards was 39%, according to the fractional surface coverage 'bins' method, which was close to the actual space utilisation of the standard mixture, 44%. Moreover, the orthogonality for the 2D-HPLC of coffee matched the predicted value of 38%. The second method employed a complex sample matrix of urine to optimise the column selections. Seven peaks were confidently matched between chromatograms by comparing relative peak areas of two detection strategies: UV absorbance and potassium permanganate chemiluminescence. It was found that the optimal combinations had an orthogonality of 35% while the actual value was closer to 30%.

3.
J Sep Sci ; 37(15): 1937-43, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24824418

ABSTRACT

The synthesis and chromatographic behavior of an analytical size mixed-mode bonded silica monolith was investigated. The monolith was functionalized by an in situ modification process of a bare silica rod with chloro(3-cyanopropyl)dimethyl silane and chlorodimethyl propyl phenyl silane solutions. These ligands were selected in order to combine both resonance and nonresonance π-type bonding within a single separation environment. Selectivity studies were undertaken using n-alkyl benzenes and polycyclic aromatic hydrocarbons in aqueous methanol and acetonitrile mobile phases to assess the methylene and aromatic selectivities of the column. The results fit with the linear solvent strength theory suggesting excellent selectivity of the column was achieved. Comparison studies were performed on monolithic columns that were functionalized separately with cyano and phenyl ligands, suggesting highly conjugated molecules were able to successfully exploit both of the π-type selectivities afforded by the two different ligands on the mixed-mode column.

4.
J Chromatogr A ; 1337: 147-54, 2014 Apr 11.
Article in English | MEDLINE | ID: mdl-24636564

ABSTRACT

To achieve the greatest peak capacity in two-dimensional high performance liquid chromatography (2D-HPLC) a gradient should be operated in both separation dimensions. However, it is known that when an injection solvent that is stronger than the initial mobile phase composition is deleterious to peak performance, thus causing problems when cutting a portion from one gradient into another. This was overcome when coupling hydrophilic interaction with reversed phase chromatography by introducing a counter gradient that changed the solvent strength of the second dimension injection. It was found that an injection solvent composition of 20% acetonitrile in water gave acceptable results in one-dimensional simulations with an initial composition of 5% acetonitrile. When this was transferred to a 2D-HPLC separation of standards it was found that a marked improvement in peak shape was gained for the moderately retained analytes (phenol and dimethyl phthalate), some improvement for the weakly retained caffeine and very little change for the strongly retained n-propylbenzene and anthracene which already displayed good chromatographic profiles. This effect was transferred when applied to a 2D-HPLC separation of a coffee extract where the indecipherable retention profile was transformed to a successful application multidimensional chromatography with peaks occupying 71% of the separation space according to the geometric approach to factor analysis.


Subject(s)
Chromatography, High Pressure Liquid/methods , Chromatography, Reverse-Phase/methods , Acetonitriles , Anthracenes/chemistry , Benzene Derivatives/chemistry , Caffeine/chemistry , Coffee/chemistry , Hydrophobic and Hydrophilic Interactions , Phenol/chemistry , Phthalic Acids/chemistry , Plant Extracts/chemistry , Solvents , Thiourea/chemistry , Water
5.
Anal Chim Acta ; 803: 188-93, 2013 Nov 25.
Article in English | MEDLINE | ID: mdl-24216214

ABSTRACT

Herein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV-visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2'-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed. Thirty-three compounds were detected via MS on the tobacco extract and 12 out of 32 compounds gave a peak height ratio (PHR) greater than 0.33 on one or more detectors. This paper serves as a case study of these limitations, illustrating why multidimensional chromatography is an important consideration when developing a comprehensive chemical detection system.


Subject(s)
Chromatography, High Pressure Liquid/methods , Nicotiana/chemistry , Plant Extracts/chemistry , 2,2'-Dipyridyl/analogs & derivatives , 2,2'-Dipyridyl/chemistry , Alkaloids/analysis , Biphenyl Compounds/chemistry , Luminescent Measurements , Manganese/chemistry , Mass Spectrometry , Organometallic Compounds/chemistry , Picrates/chemistry , Potassium Permanganate/chemistry , Spectrophotometry, Ultraviolet
6.
J Sep Sci ; 36(21-22): 3503-10, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24039071

ABSTRACT

Two multidimensional HPLC separations of an Australian red wine are presented, >70% of the available separation space was used. A porous graphitic carbon (PGC) stationary phase was used as the first dimension in both separations with both RP core-shell and hydrophilic interaction chromatography fully porous columns used separately in the second dimension. To overcome peak analysis problems caused by signal noise and low detection limits, the data were pre-processed with penalised least-squares smoothing. The PGC × RP combination separated 85 peaks with a spreading angle of 71° and the PGC × hydrophilic interaction chromatography separated 207 peaks with a spreading angle of 80°. Both 2D-HPLC steps were completed in 76 min using a comprehensive stop-and-go approach. A smoothing step was added to peak-picking processes and was able to greatly reduce the number of false peaks present due to noise in the chromatograms. The required thresholds were not able to ignore the noise because of the small magnitude of the peaks; 1874 peaks were located in the non-smoothed PGC × RP separation that reduced to 227 peaks after smoothing was included.


Subject(s)
Algorithms , Chromatography, High Pressure Liquid/methods , Wine/analysis , Carbon/chemistry
7.
J Sep Sci ; 35(9): 1110-7, 2012 May.
Article in English | MEDLINE | ID: mdl-22689486

ABSTRACT

The need to monitor biogenic amines levels is essential for many areas of the food industry for two main reasons: the caustic nature and potential toxicity of these amines, and the potential to use amine levels as markers for freshness and quality in foodstuffs. Optimised analysis conditions used for the determination of biogenic amines derivatised with 2-napthyloxycarbonyl chloride has been applied to different pet food samples to assess the effectiveness of this method for complex sample matrices. Further to this, the use of high-resolution mass spectrometry has enabled the previously unconfirmed derivatised form of seven biogenic amines to be established. The derivatised forms identified include as mono substituted (tryptamine and histamine), bisubstituted (putrescine, cadaverine and tyramine), trisubstituted (spermidine) and tetrasubstituted (spermine). The methodology of biogenic amine determination was performed successfully to a range of pet food products highlighting the applicability to a variety of complex sample matrices.


Subject(s)
Animal Feed/analysis , Biogenic Amines/chemistry , Food Contamination/analysis , Mass Spectrometry/methods , Naphthalenes/chemistry , Molecular Structure
8.
Rapid Commun Mass Spectrom ; 26(8): 943-9, 2012 Apr 30.
Article in English | MEDLINE | ID: mdl-22396031

ABSTRACT

RATIONALE: Speed of analysis is a significant limitation to current high-performance liquid chromatography/mass spectrometry (HPLC/MS) and ultra-high-pressure liquid chromatography (UHPLC)/MS systems. The flow rate limitations of MS detection require a compromise in the chromatographic flow rate, which in turn reduces throughput, and when using modern columns, a reduction in separation efficiency. Commonly, this restriction is combated through the post-column splitting of flow prior to entry into the mass spectrometer. However, this results in a loss of sensitivity and a loss in efficiency due to the post-extra column dead volume. METHODS: A new chromatographic column format known as 'parallel segmented flow' involves the splitting of eluent flow within the column outlet end fitting, and in this study we present its application on a HPLC electrospray ionization time-of-flight mass spectrometer. RESULTS: Using parallel segmented flow, column flow rates as high as 2.5 mL/min were employed in the analysis of amino acids without post-column splitting to the mass spectrometer. Furthermore, when parallel segmented flow chromatography columns were employed, the sensitivity was more than twice that of conventional systems with post-column splitting when the same volume of mobile phase was passed through the detector. CONCLUSIONS: These finding suggest that this type of column technology will particularly enhance the capabilities of modern LC/MS enabling both high-throughput and sensitive mass spectral detection.


Subject(s)
Amino Acids/analysis , Chromatography, High Pressure Liquid/instrumentation , Spectrometry, Mass, Electrospray Ionization/instrumentation , Sensitivity and Specificity , Spectrometry, Mass, Electrospray Ionization/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...