Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 43(9): 4996, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27587030

ABSTRACT

PURPOSE: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). METHODS: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. RESULTS: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. CONCLUSIONS: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.


Subject(s)
Electrical Equipment and Supplies/standards , Image Processing, Computer-Assisted/methods , Signal-To-Noise Ratio , Wavelet Analysis , Artifacts , Quality Control
2.
Biotechnol Bioeng ; 91(4): 460-7, 2005 Aug 20.
Article in English | MEDLINE | ID: mdl-15959893

ABSTRACT

We report a novel application for the operator-repressor titration (ORT) plasmid maintenance system. The ability of ORT to maintain a plasmid during production of DNA has been demonstrated previously. In this study, we have used the ORT system to maintain a plasmid during high cell density cultivation and expression of a recombinant protein. No evidence of plasmid loss was seen during protein expression at high cell densities. In addition, the quantity of protein produced using this system was similar to traditional plasmid maintenance systems.


Subject(s)
Aldehyde-Lyases/biosynthesis , Escherichia coli/genetics , Gene Expression Regulation, Bacterial/physiology , Operator Regions, Genetic , Plasmids , Repressor Proteins/genetics , Aldehyde-Lyases/analysis , Animals , Escherichia coli/enzymology , Fermentation , Gene Expression Regulation, Bacterial/genetics , Industrial Microbiology/methods , Plasmids/genetics , Plasmids/metabolism , Recombinant Proteins/analysis , Recombinant Proteins/biosynthesis , Repressor Proteins/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...