Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add more filters










Publication year range
2.
Sci Rep ; 14(1): 5139, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38429500

ABSTRACT

We apply X-ray ptycho-tomography to perform high-resolution, non-destructive, three-dimensional (3D) imaging of Fe-rich inclusions in paleomagnetically relevant materials (zircon single crystals from the Bishop Tuff ignimbrite). Correlative imaging using quantum diamond magnetic microscopy combined with X-ray fluorescence mapping was used to locate regions containing potential ferromagnetic remanence carriers. Ptycho-tomographic reconstructions with voxel sizes 85 nm and 21 nm were achievable across a field-of-view > 80 µm; voxel sizes as small as 5 nm were achievable over a limited field-of-view using local ptycho-tomography. Fe-rich inclusions 300 nm in size were clearly resolved. We estimate that particles as small as 100 nm-approaching single-domain threshold for magnetite-could be resolvable using this "dual-mode" methodology. Fe-rich inclusions (likely magnetite) are closely associated with apatite inclusions that have no visible connection to the exterior surface of the zircon (e.g., via intersecting cracks). There is no evidence of radiation damage, alteration, recrystallisation or deformation in the host zircon or apatite that could provide alternative pathways for Fe infiltration, indicating that magnetite and apatite grew separately as primary phases in the magma, that magnetite adhered to the surfaces of the apatite, and that the magnetite-coated apatite was then encapsulated as primary inclusions within the growing zircon. Rarer examples of Fe-rich inclusions entirely encapsulated by zircon are also observed. These observations support the presence of primary inclusions in relatively young and pristine zircon crystals. Combining magnetic and tomography results we deduce the presence of magnetic carriers that are in the optimal size range for carrying strong and stable paleomagnetic signals but that remain below the detection limits of even the highest-resolution X-ray tomography reconstructions. We recommend the use of focused ion beam nanotomography and/or correlative transmission electron microscopy to directly confirm the presence of primary magnetite in the sub 300 nm range as a necessary step in targeted paleomagnetic workflows.

3.
Adv Mater ; 35(46): e2305549, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37735999

ABSTRACT

In recent years, halide perovskite materials have been used to make high-performance solar cells and light-emitting devices. However, material defects still limit device performance and stability. Here, synchrotron-based Bragg coherent diffraction imaging is used to visualize nanoscale strain fields, such as those local to defects, in halide perovskite microcrystals. Significant strain heterogeneity within MAPbBr3 (MA = CH3 NH3 + ) crystals is found in spite of their high optoelectronic quality, and both 〈100〉 and 〈110〉 edge dislocations are identified through analysis of their local strain fields. By imaging these defects and strain fields in situ under continuous illumination, dramatic light-induced dislocation migration across hundreds of nanometers is uncovered. Further, by selectively studying crystals that are damaged by the X-ray beam, large dislocation densities and increased nanoscale strains are correlated with material degradation and substantially altered optoelectronic properties assessed using photoluminescence microscopy measurements. These results demonstrate the dynamic nature of extended defects and strain in halide perovskites, which will have important consequences for device performance and operational stability.

4.
Opt Express ; 31(10): 15791-15809, 2023 May 08.
Article in English | MEDLINE | ID: mdl-37157672

ABSTRACT

Ptychography is a form of lens-free coherent diffractive imaging now used extensively in electron and synchrotron-based X-ray microscopy. In its near-field implementation, it offers a route to quantitative phase imaging at an accuracy and resolution competitive with holography, with the added advantages of extended field of view and blind deconvolution of the illumination beam profile from the sample image. In this paper we show how near-field ptychography can be combined with a multi-slice model, adding to this list of advantages the unique ability to recover high-resolution phase images of larger samples, whose thickness places them beyond the depth of field of alternative methods.

5.
Commun Phys ; 6(1): 288, 2023.
Article in English | MEDLINE | ID: mdl-38665412

ABSTRACT

Laser-plasma accelerators are compact linear accelerators based on the interaction of high-power lasers with plasma to form accelerating structures up to 1000 times smaller than standard radiofrequency cavities, and they come with an embedded X-ray source, namely betatron source, with unique properties: small source size and femtosecond pulse duration. A still unexplored possibility to exploit the betatron source comes from combining it with imaging methods able to encode multiple information like transmission and phase into a single-shot acquisition approach. In this work, we combine edge illumination-beam tracking (EI-BT) with a betatron X-ray source and present the demonstration of multimodal imaging (transmission, refraction, and scattering) with a compact light source down to the femtosecond timescale. The advantage of EI-BT is that it allows multimodal X-ray imaging technique, granting access to transmission, refraction and scattering signals from standard low-coherence laboratory X-ray sources in a single shot.

6.
Sci Rep ; 12(1): 7846, 2022 05 12.
Article in English | MEDLINE | ID: mdl-35551474

ABSTRACT

X-ray ptychography is a coherent scanning imaging technique widely used at synchrotron facilities for producing quantitative phase images beyond the resolution limit of conventional x-ray optics. The scanning nature of the technique introduces an inherent overhead to the collection at every scan position and limits the acquisition time of each 2D projection. The overhead associated with motion can be minimised with a continuous-scanning approach. Here we present an acquisition architecture based on continuous-scanning and up-triggering which allows to record ptychographic datasets at up to 9 kHz. We demonstrate the method by applying it to record 2D scans at up to 273 µm2/s and 3D scans of a (20 µm)3 volume in less than three hours. We discuss the current limitations and the outlook toward the development of sub-second 2D acquisition and minutes-long 3D ptychographic tomograms.


Subject(s)
Synchrotrons , Tomography, X-Ray , Motion , Optics and Photonics , X-Rays
7.
J Synchrotron Radiat ; 28(Pt 6): 1916-1920, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34738946

ABSTRACT

X-ray ptychography and X-ray fluorescence are complementary nanoscale imaging techniques, providing structural and elemental information, respectively. Both methods acquire data by scanning a localized beam across the sample. X-ray ptychography processes the transmission signal of a coherent illumination interacting with the sample, to produce images with a resolution finer than the illumination spot and step size. By enlarging both the spot and the step size, the technique can cover extended regions efficiently. X-ray fluorescence records the emitted spectra as the sample is scanned through the localized beam and its spatial resolution is limited by the spot and step size. The requisites for fast ptychography and high-resolution fluorescence appear incompatible. Here, a novel scheme that mitigates the difference in requirements is proposed. The method makes use of two probes of different sizes at the sample, generated by using two different energies for the probes and chromatic focusing optics. The different probe sizes allow to reduce the number of acquisition steps for the joint fluorescence-ptychography scan compared with a standard single beam scan, while imaging the same field of view. The new method is demonstrated experimentally using two undulator harmonics, a Fresnel zone plate and an energy discriminating photon counting detector.


Subject(s)
Optical Imaging , Photons , Radiography , X-Rays
8.
Angew Chem Int Ed Engl ; 60(40): 21772-21777, 2021 Sep 27.
Article in English | MEDLINE | ID: mdl-34339595

ABSTRACT

Understanding catalyst deactivation by coking is crucial for knowledge-based catalyst and process design in reactions with carbonaceous species. Post-mortem analysis of catalyst coking is often performed by bulk characterization methods. Here, hard X-ray ptychographic computed tomography (PXCT) was used to study Ni/Al2 O3 catalysts for CO2 methanation and CH4 dry reforming after artificial coking treatment. PXCT generated quantitative 3D maps of local electron density at ca. 80 nm resolution, allowing to visualize and evaluate the severity of coking in entire catalyst particles of ca. 40 µm diameter. Coking was primarily revealed in the nanoporous solid, which was not detectable in resolved macropores. Coke formation was independently confirmed by operando Raman spectroscopy. PXCT is highlighted as an emerging characterization tool for nanoscale identification, co-localization, and potentially quantification of deactivation phenomena in 3D space within entire catalyst particles.

10.
Phys Rev Lett ; 126(19): 193902, 2021 May 14.
Article in English | MEDLINE | ID: mdl-34047586

ABSTRACT

X-ray ptychography has revolutionized nanoscale phase contrast imaging at large-scale synchrotron sources in recent years. We present here the first successful demonstration of the technique in a small-scale laboratory setting. An experiment was conducted with a liquid metal-jet x-ray source and a single photon-counting detector with a high spectral resolution. The experiment used a spot size of 5 µm to produce a ptychographic phase image of a Siemens star test pattern with a submicron spatial resolution. The result and methodology presented show how high-resolution phase contrast imaging can now be performed at small-scale laboratory sources worldwide.

11.
Chromosome Res ; 29(1): 107-126, 2021 03.
Article in English | MEDLINE | ID: mdl-33786705

ABSTRACT

Studies of the structural and functional role of chromosomes in cytogenetics have spanned more than 10 decades. In this work, we take advantage of the coherent X-rays available at the latest synchrotron sources to extract the individual masses of all 46 chromosomes of metaphase human B and T cells using hard X-ray ptychography. We have produced 'X-ray karyotypes' of both heavy metal-stained and unstained spreads to determine the gain or loss of genetic material upon low-level X-ray irradiation doses due to radiation damage. The experiments were performed at the I-13 beamline, Diamond Light Source, Didcot, UK, using the phase-sensitive X-ray ptychography method.


Subject(s)
Chromosomes, Human , Synchrotrons , Humans , Karyotyping , X-Rays
12.
ACS Nano ; 15(1): 1321-1330, 2021 Jan 26.
Article in English | MEDLINE | ID: mdl-33355443

ABSTRACT

Due to complex degradation mechanisms, disparities between the theoretical and practical capacities of lithium-ion battery cathode materials persist. Specifically, Ni-rich chemistries such as LiNi0.8Mn0.1Co0.1O2 (or NMC811) are one of the most promising choices for automotive applications; however, they continue to suffer severe degradation during operation that is poorly understood, thus challenging to mitigate. Here we use operando Bragg coherent diffraction imaging for 4D analysis of these mechanisms by inspecting the individual crystals within primary particles at various states of charge (SoC). Although some crystals were relatively homogeneous, we consistently observed non-uniform distributions of inter- and intracrystal strain at all measured SoC. Pristine structures may already possess heterogeneities capable of triggering crystal splitting and subsequently particle cracking. During low-voltage charging (2.7-3.5 V), crystal splitting may still occur even during minimal bulk deintercalation activity; and during discharging, rotational effects within parallel domains appear to be the precursor for the nucleation of screw dislocations at the crystal core. Ultimately, this discovery of the central role of crystal grain splitting in the charge/discharge dynamics may have ramifications across length scales that affect macroscopic performance loss during real-world battery operation.

13.
Sci Rep ; 10(1): 22056, 2020 12 16.
Article in English | MEDLINE | ID: mdl-33328563

ABSTRACT

The structural form and elemental distribution of material originating from different Fukushima Daiichi Nuclear Power Plant reactors (Units 1 and 3) is hereby examined to elucidate their contrasting release dynamics and the current in-reactor conditions to influence future decommissioning challenges. Complimentary computed X-ray absorption tomography and X-ray fluorescence data show that the two suites of Si-based material sourced from the different reactor Units have contrasting internal structure and compositional distribution. The known event and condition chronology correlate with the observed internal and external structures of the particulates examined, which suggest that Unit 1 ejecta material sustained a greater degree of melting than that likely derived from reactor Unit 3. In particular, we attribute the near-spherical shape of Unit 1 ejecta and their internal voids to there being sufficient time for surface tension to round these objects before the hot (and so relatively low viscosity) silicate melt cooled to form glass. In contrast, a more complex internal form associated with the sub-mm particulates invoked to originate from Unit 3 suggest a lower peak temperature, over a longer duration. Using volcanic analogues, we consider the structural form of this material and how it relates to its environmental particulate stability and the bulk removal of residual materials from the damaged reactors. We conclude that the brittle and angular Unit 3 particulate are more susceptible to further fragmentation and particulate generation hazard than the round, higher-strength, more homogenous Unit 1 material.

14.
Sci Rep ; 10(1): 6526, 2020 Apr 16.
Article in English | MEDLINE | ID: mdl-32300125

ABSTRACT

We present here a new method of performing X-ray edge-subtraction ptychographic imaging by combining multiple harmonics from an undulator synchtrotron source and an energy discriminating photon counting detector. Conventionally, monochromatic far-field X-ray ptychography is used to perform edge subtraction through the use of multiple monochromatic energy scans to obtain spectral information for a variety of applications. Here, we use directly the undulator spectrum from a synchrotron source, selecting two separate harmonics post sample using the Pixirad-1/Pixie-III detector. The result is two monochromatic images, above and below an absorption edge of interest. The proposed method is applied to obtain Au L-edge subtraction imaging of a Au-Ni grid test sample. The Au L-edge subtraction is particularly relevant for the identification of gold nanoparticles for biomedical applications. Switching the energy scan mechanism from a mechanical monochromator to an electronic detector threshold allows for faster spectral data collection with improved stability.

15.
Sci Rep ; 10(1): 1636, 2020 01 31.
Article in English | MEDLINE | ID: mdl-32005927

ABSTRACT

Both the three-dimensional internal structure and elemental distribution of near-field radioactive fallout particulate material released during the March 2011 accident at the Fukushima Daiichi Nuclear Power Plant is analysed using combined high-resolution laboratory and synchrotron radiation x-ray techniques. Results from this study allow for the proposition of the likely formation mechanism of the particles, as well as the potential risks associated with their existence in the environment, and the likely implications for future planned reactor decommissioning. A suite of particles is analyzed from a locality 2 km from the north-western perimeter of the site - north of the primary contaminant plume in an area formerly attributed to being contaminated by fallout from reactor Unit 1. The particles are shown to exhibit significant structural similarities; being amorphous with a textured exterior, and containing inclusions of contrasting compositions, as well as an extensive internal void volume - bimodal in its size distribution. A heterogeneous distribution of the various elemental constituents is observed inside a representative particle, which also exhibited a Fukushima-derived radiocesium (134Cs, 135Cs and 137Cs) signature with negligible natural Cs. We consider the structure and composition of the particle to suggest it formed from materials associated with the reactor Unit 1 building explosion, with debris fragments embedded into the particles surface. Such a high void ratio, comparable to geological pumice, suggests such material formed during a rapid depressurisation and is potentially susceptible to fragmentation through attrition.


Subject(s)
Cesium Radioisotopes/chemistry , Radioactive Fallout/analysis , Dust/analysis , Fukushima Nuclear Accident , Japan , Nuclear Power Plants , Radiation Monitoring/methods , Radiography/methods , Soil Pollutants, Radioactive , Synchrotrons , Water Pollutants, Radioactive/analysis , X-Rays
16.
Opt Lett ; 44(18): 4622-4625, 2019 Sep 15.
Article in English | MEDLINE | ID: mdl-31517948

ABSTRACT

In this Letter, we report on the creation of hard x-ray beams carrying orbital angular momentum of topological charge -ℏ and -3ℏ at a photon energy of 8.2 keV via spiral phase plates made out of fused silica by ultrashort-pulsed laser ablation. The phase plates feature a smooth phase ramp with a 0.5 µm nominal step height and a surface roughness of 0.5 µm. The measured vortex beams show submicrometer-sized donut rings and agree well with numerical modeling. Fused silica phase plates are potentially suited to manipulate the electromagnetic field in highly intense x-ray beams at x-ray free-electron laser sources.

17.
Sci Rep ; 9(1): 12278, 2019 08 22.
Article in English | MEDLINE | ID: mdl-31439864

ABSTRACT

We present a new method of single acquisition spectroscopic imaging with high spatial resolution. The technique is based on the combination of polychromatic synchrotron radiation and ptychographic imaging with a recently developed energy discriminating detector. We demonstrate the feasibility with a Ni-Cu test sample recorded at I13-1 of the Diamond Light Source, UK. The two elements can be clearly distinguished and the Ni absorption edge is identified. The results prove the feasibility of obtaining high-resolution structural and chemical images within a single acquisition using a polychromatic X-ray beam. The capability of resolving the absorption edge applies to a wide range of research areas, such as magnetic domains imaging and element specific investigations in biological, materials, and earth sciences. The method utilises the full available radiation spectrum and is therefore well suited for broadband radiation sources.

18.
Nat Commun ; 10(1): 2801, 2019 06 26.
Article in English | MEDLINE | ID: mdl-31243294

ABSTRACT

Here we report the results of multiple analytical techniques on sub-mm particulate material derived from Unit 1 of the Fukushima Daiichi Nuclear Power Plant to provide a better understanding of the events that occurred and the environmental legacy. Through combined x-ray fluorescence and absorption contrast micro-focused x-ray tomography, entrapped U particulate are observed to exist around the exterior circumference of the highly porous Si-based particle. Further synchrotron radiation analysis of a number of these entrapped particles shows them to exist as UO2-identical to reactor fuel, with confirmation of their nuclear origin shown via mass spectrometry analysis. While unlikely to represent an environmental or health hazard, such assertions would likely change should break-up of the Si-containing bulk particle occur. However, more important to the long-term decommissioning of the reactors at the FDNPP (and environmental clean-upon), is the knowledge that core integrity of reactor Unit 1 was compromised with nuclear material existing outside of the reactors primary containment.

19.
Ultramicroscopy ; 203: 88-94, 2019 Aug.
Article in English | MEDLINE | ID: mdl-30773416

ABSTRACT

The nature of the atomic structure of many non-crystalline materials remains a long-standing open question. We use X-ray scattering to model electron images of amorphous materials, where the analogue 'atoms' consist of 1 µm diameter glass beads. The beads form a substantially random close-packed structure, but are partially ordered in places. X-ray ptycho-tomography reveals the exact position of the beads in 3D and so can be used to compare the modelled electron image with full knowledge of the underlying real structure. Using this, we repeat an experiment reported by Archie Howie and colleagues in 1978 that sought to test for real structure in bright-field electron images of amorphous materials; we demonstrate the validity of the technique, at least in the case of the resolution of the microscopes available at that time and the first Born approximation. We also illustrate how extremely demanding it would have been to infer 3D structure of amorphous material from pairs of stereoscopic images obtained with the same experimental kit: an approach that Archie proposed in the 1970s. We briefly discuss the possibility of using electron ptycho-tomography to solve the amorphous structure problem.

20.
Opt Express ; 27(2): 533-542, 2019 Jan 21.
Article in English | MEDLINE | ID: mdl-30696138

ABSTRACT

Ptychographic X-ray computed tomography is a phase-contrast imaging technique capable of retrieving three-dimensional maps of the index of refraction of the imaged volumes with nanometric resolution. Despite its unmatched reach, its application remains prerogative of a limited number of laboratories at synchrotron sources. We present a detailed description of an experimental procedure and a data analysis pipeline which can be both exploited for ptychographic X-ray computed tomography experiments at any high-brilliance X-ray source. These have been validated at the I13-1 Coherence Branchline within the first experiment of its kind to be successfully carried out on a biological sample at Diamond Light Source.

SELECTION OF CITATIONS
SEARCH DETAIL
...