Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Type of study
Publication year range
1.
Phys Med ; 29(5): 461-9, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23352766

ABSTRACT

A geometric acrylic phantom was designed and built for dose distribution verification in Stereotactic Radiosurgery. Acrylic objects representing the tumor tissue, (target volume (TV)), and the organ at risk (OAR), the brainstem, were inserted inside this phantom. The TV is represented by two semi-spheres of acrylic with a diameter of 13.0 mm, both having a central cavity for accommodation of a TLD-100 detector and a small radiochromic Gafchromic EBT film. The OAR is represented by the two parts of a 38.0 mm length acrylic cylinder with a diameter 18.0 mm and cavities along the cylinder central axis able to accommodate 5 TLD - 100 detectors and another of EBT film between the two cylinder parts. This experimental setup was submitted to a radiosurgical treatment, after which the TL dosimeters were evaluated and their responses were compared with the planned dose values. The radiochromic EBT films showed the dose distributions. The linear accelerator used was a Varian 2300 C/D, generating a 6 MV photon beam. The investigated phantom system was able to check the accuracy of dose delivery to predetermined points and the dose distribution due to stereotactic radiosurgery treatments and proved to be a good tool for quality control in these situations.


Subject(s)
Film Dosimetry/instrumentation , Phantoms, Imaging , Radiation Dosage , Radiosurgery , Thermoluminescent Dosimetry/instrumentation , Radiotherapy Planning, Computer-Assisted
2.
Radiol. bras ; 42(2): 83-88, mar.-abr. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-513148

ABSTRACT

OBJETIVO: O objetivo deste trabalho foi desenvolver um sistema dosimétrico termoluminescente capaz de avaliar as doses administradas ao reto de pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino. MATERIAIS E MÉTODOS: O material termoluminescente utilizado para a avaliação da dose no reto foi o LiF:Mg,Ti,Na na forma de pó. O pó foi separado em pequenas porções de 34 mg, que foram acomodadas em um tubo capilar. Este tubo foi colocado em uma sonda retal, que era introduzida no reto da paciente. RESULTADOS: As doses administradas ao reto de seis pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino foram avaliadas com dosímetros termoluminescentes e apresentaram boa concordância com os valores planejados, com base em duas radiografias ortogonais da paciente, imagens ântero-posterior e lateral. CONCLUSÃO: O sistema de dosimetria termoluminescente utilizado no presente trabalho é simples e de fácil utilização quando comparado a outros métodos de dosimetria do reto. Ele mostrou-se eficiente na avaliação da dose no reto de pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino.


OBJECTIVE: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. MATERIALS AND METHODS: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. RESULTS: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. CONCLUSION: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer.


Subject(s)
Humans , Female , Brachytherapy , Thermoluminescent Dosimetry/methods , Lithium/administration & dosage , Uterine Cervical Neoplasms/drug therapy , Radioisotopes , Titanium/administration & dosage , Brachytherapy/methods , Dose-Response Relationship, Drug , Lithium/therapeutic use , Magnesium , Rectum/radiation effects , Sodium
SELECTION OF CITATIONS
SEARCH DETAIL
...