Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Imaging ; 37: 234-242, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27939435

ABSTRACT

INTRODUCTION: Although T1 weighted spin echo (T1W SE) images are widely used to study anatomical details and pathologic abnormalities of the brain, its role in delineation of lesions and reduction of artifacts has not been thoroughly investigated. BLADE is a fairly new technique that has been reported to reduce motion artifacts and improve image quality. OBJECTIVE: The primary objective of this study is to compare the quality of T1-weighted fluid attenuated inversion recovery (FLAIR) images with BLADE technique (T1W FLAIR BLADE) and the quality of T1W SE images in the MR imaging of the brain. The goal is to highlight the advantages of the two sequences as well as which one can better reduce flow and motion artifacts so that the imaging of the lesions will not be impaired. MATERIALS AND METHODS: Brain examinations with T1W FLAIR BLADE and T1W SE sequences were performed on 48 patients using a 1.5T scanner. These techniques were evaluated by two radiologists based on: a) a qualitative analysis i.e. overall image quality, presence of artifacts, CSF nulling; and b) a quantitative analysis of signal-to-noise ratios (SNR), contrast-to-noise ratios (CNR) and Relative Contrast. The statistical analysis was performed using the Kruskal-Wallis non-parametric system. RESULTS: In the qualitative analysis, BLADE sequences had a higher scoring than the conventional sequences in all the cases. The overall image quality was better on T1W FLAIR BLADE. Motion and flow-related artifacts were lower in T1W FLAIR BLADE. Regarding the SNR measurements, T1W SE appeared to have higher values in the majority of cases, whilst T1W-FLAIR BLADE had higher values in the CNR and Relative Contrast measurements. CONCLUSION: T1W FLAIR BLADE sequence appears to be superior to T1W SE in overall image quality and reduction of motion and flow-pulsation artifacts as well as in nulling CSF and has been preferred by the clinicians. T1W FLAIR BLADE may be an alternative approach in brain MRI imaging.


Subject(s)
Brain Diseases/diagnostic imaging , Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Artifacts , Female , Humans , Male , Middle Aged , Motion , Neuroimaging/methods , Reproducibility of Results , Signal-To-Noise Ratio , Young Adult
2.
Magn Reson Imaging ; 33(2): 194-200, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25461304

ABSTRACT

PURPOSE: To assess the efficacy of the BLADE technique (MR imaging with 'rotating blade-like k-space covering') to significantly reduce motion, truncation, flow and other artifacts in cervical spine compared to the conventional technique. MATERIALS AND METHODS: In eighty consecutive subjects, who had been routinely scanned for cervical spine examination, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0: non-visualization; 1: poor; 2: average; 3: good; 4: excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). RESULTS: In quantitative analysis, the CNR values of the CSF/SC between TIRM SAG and TIRM SAG BLADE were found to present statistically significant differences (p < 0.001). Regarding motion and truncation artifacts, the T2 TSE BLADE SAG was superior compared to the T2 TSE SAG, and the T2 TIRM BLADE SAG was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM BLADE SAG eliminated more artifacts than T2 TIRM SAG. CONCLUSIONS: In cervical spine MRI, BLADE sequences appear to significantly reduce motion, truncation and flow artifacts and improve image quality. BLADE sequences are proposed to be used for uncooperative subjects. Nevertheless, more research needs to be done by testing additional specific pathologies.


Subject(s)
Cervical Vertebrae/pathology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Motion , Adolescent , Adult , Algorithms , Artifacts , Contrast Media/chemistry , Diagnostic Imaging , Female , Humans , Male , Middle Aged , Reproducibility of Results , Signal-To-Noise Ratio , Young Adult
3.
Magn Reson Imaging ; 31(10): 1766-70, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23993790

ABSTRACT

The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5T. In both patients, one more lesion was identified with the BLADE sequences than with the conventional ones. Consequently, we suggest the use of BLADE T2-TSE and BLADE T2-TIRM sequences in place of conventional ones for sagittal examination of the cervical spinal cord of multiple sclerosis patients. The advantages of ΤΙRΜ to reveal the pathology of the cervical spinal cord and the advantage of BLADE sequences to improve image quality should be combined in a sequence that could be ideal for cervical spinal cord examinations.


Subject(s)
Algorithms , Cervical Vertebrae/pathology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Multiple Sclerosis/pathology , Spinal Cord/pathology , Female , Humans , Patient Positioning/methods , Reproducibility of Results , Sensitivity and Specificity , Young Adult
4.
Magn Reson Imaging ; 31(8): 1255-62, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23876261

ABSTRACT

The purpose of this study, is to compare the sequences: 1) proton density (PD) BLADE (BLADE is a PROPELLER-equivalent implementation of the Siemens Medical System) with fat saturation (FS) coronal (COR), 2) PD FS COR, 3) multi-planar reconstruction (MPR) with 3mm slice thickness and 4) multi-planar reconstruction (MPR) with 1.5mm slice thickness, both from the T2 3D-double-echo steady state (DESS) with water excitation (WE) sagittal (SAG), regarding their abilities to identify changes in the femorotibial condyle cartilage in knee MRI examinations. Thirty three consecutive patients with osteoarthritis (18 females, 15 males; mean age 56years, range 37-71years), who had been routinely scanned for knee examination using the previously mentioned image acquisition techniques, participated in the study. A quantitative analysis was performed based on the relative contrast (ReCON) measurements, which were taken both on normal tissues as well as on pathologies. Additionally, a qualitative analysis was performed by two radiologists. Motion and pulsatile flow artifacts were evaluated. The PD BLADE FS COR sequence produced images of higher contrast between Menisci and Cartilage, Fluid and Cartilage, Pathologies and Cartilage as well as of the Conspicuousness Superficial Cartilage and it was found to be superior to the other sequences (p<0.001). The sequences T2 3D DESS 1.5mm and T2 3D DESS 3mm were significantly superior to the PD BLADE FS COR and the PD FS COR sequences in the visualization of Bone and Cartilage and the Conspicuousness Deep Surface Cartilage. This pattern of results is also confirmed by the quantitative analysis. PD FS BLADE sequences are ideal for the depiction of the cartilage pathologies compared to the conventional PD FS and T2 3D DESS sequences.


Subject(s)
Adipose Tissue/pathology , Algorithms , Cartilage, Articular/pathology , Image Interpretation, Computer-Assisted/methods , Knee Joint/pathology , Osteoarthritis, Knee/pathology , Adipose Tissue/metabolism , Adult , Aged , Body Water/metabolism , Cartilage, Articular/metabolism , Female , Humans , Image Enhancement/methods , Knee Joint/metabolism , Male , Middle Aged , Osteoarthritis, Knee/metabolism , Reproducibility of Results , Sensitivity and Specificity
5.
Magn Reson Imaging ; 31(6): 882-90, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23602722

ABSTRACT

The purpose of this study is to evaluate the ability of T2 turbo spin echo (TSE) axial and sagittal BLADE sequences in reducing or even eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MRI examinations. Forty four patients, who had routinely undergone a lumbar spine examination, participated in the study. The following pairs of sequences with and without BLADE were compared: a) T2 TSE Sagittal (SAG) in thirty two cases, and b) T2 TSE Axial (AX) also in thirty two cases. Both quantitative and qualitative analyses were performed based on measurements in different normal anatomical structures and examination of seven characteristics, respectively. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion, pulsatile flow and cross-talk artifacts was evaluated. Based on the results of the qualitative analysis for the different sequences and anatomical structures, the BLADE sequences were found to be significantly superior to the conventional ones in all the cases. The BLADE sequences eliminated the motion artifacts in all the cases. In our results, it was found that in the examined sequences (sagittal and axial) the differences between the BLADE and conventional sequences regarding the elimination of motion, pulsatile flow and cross-talk artifacts were statistically significant. In all the comparisons, the T2 TSE BLADE sequences were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable of potentially eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MR images and producing high quality images in collaborative and non-collaborative patients.


Subject(s)
Algorithms , Artifacts , Image Interpretation, Computer-Assisted/methods , Lumbar Vertebrae/pathology , Magnetic Resonance Imaging/methods , Spinal Diseases/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Movement , Pulsatile Flow , Reproducibility of Results , Sensitivity and Specificity , Signal-To-Noise Ratio , Young Adult
6.
Magn Reson Imaging ; 31(2): 189-200, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22959874

ABSTRACT

The purpose of this study is to compare two types of sequences in brain magnetic resonance (MR) examinations of uncooperative and cooperative patients. For each group of patients, the pairs of sequences that were compared were two T2-weighted (T2-W) fluid attenuated inversion recovery sequences with different k-space trajectories (conventional Cartesian and BLADE) and two T2-TSE weighted with different k-space trajectories (conventional Cartesian and BLADE). Twenty-three consecutive uncooperative patients and 44 cooperative patients, who routinely underwent brain MR imaging examination, participated in the study. Both qualitative and quantitative analyses were performed based on the signal-to-noise ratio, contrast-to-noise ratio (CNR), and relative contrast (ReCon) measures of normal anatomic structures. The qualitative analysis was performed by experienced radiologists. Also, the presence of motion, other (e.g., Gibbs, susceptibility artifacts, phase encoding from vessels) artifacts and pulsatile flow artifacts was evaluated. In the uncooperative group of patients, BLADE sequences were superior to the corresponding conventional sequences in all the cases. Furthermore, the differences were found to be statistically significant in almost all the cases. In the cooperative group of patients, BLADE sequences were superior to the conventional sequences with the differences of the CNR and ReCon values in nine cases being statistically significant. Furthermore, BLADE sequences eliminated motion and other artifacts and T2 FLAIR BLADE sequences eliminated pulsatile flow artifacts. BLADE sequences (T2-TSE and T2 FLAIR) should be used in brain MR examinations of uncooperative patients. In cooperative patients, T2-TSE BLADE sequences may be used as part of the routine protocol and orbital examinations. T2 FLAIR BLADE sequences may be used optionally in examinations of AVM, orbits, haemorrhages, ventricular lesions, lesions in the frontal lobe, periventricular lesions, lesions in regions close to artifacts and lesions in posterior fossa.


Subject(s)
Brain/pathology , Magnetic Resonance Imaging/methods , Adolescent , Adult , Aged , Aged, 80 and over , Algorithms , Artifacts , Contrast Media/pharmacology , Female , Humans , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Motion , Pulsatile Flow , Signal-To-Noise Ratio , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...