Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthop Case Rep ; 7(4): 36-38, 2017.
Article in English | MEDLINE | ID: mdl-29181350

ABSTRACT

INTRODUCTION: Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. CASE REPORT: A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. CONCLUSION: A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients.

2.
Bone Joint J ; 96-B(2): 263-9, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24493195

ABSTRACT

We reviewed the outcome of 69 uncemented, custom-made, distal femoral endoprosthetic replacements performed in 69 patients between 1994 and 2006. There were 31 women and 38 men with a mean age at implantation of 16.5 years (5 to 37). All procedures were performed for primary malignant bone tumours of the distal femur. At a mean follow-up of 124.2 months (4 to 212), 53 patients were alive, with one patient lost to follow-up. All nine implants (13.0%) were revised due to aseptic loosening at a mean of 52 months (8 to 91); three implants (4.3%) were revised due to fracture of the shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic fracture. Bone remodelling associated with periosteal cortical thinning adjacent to the uncemented intramedullary stem was seen in 24 patients but this did not predispose to failure. All aseptically loose implants in this series were diagnosed to be loose within the first five years. The results from this study suggest that custom-made uncemented distal femur replacements have a higher rate of aseptic loosening compared to published results for this design when used with cemented fixation. Loosening of uncemented replacements occurs early indicating that initial fixation of the implant is crucial.


Subject(s)
Coated Materials, Biocompatible , Durapatite , Femoral Neoplasms/surgery , Forecasting , Prosthesis Implantation/methods , Adolescent , Adult , Bone Cements , Child , Child, Preschool , Female , Femoral Neoplasms/diagnostic imaging , Femoral Neoplasms/mortality , Follow-Up Studies , Humans , Male , Prosthesis Design , Radiography , Retrospective Studies , Survival Rate/trends , Treatment Outcome , United Kingdom/epidemiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...