Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1654: 462449, 2021 Sep 27.
Article in English | MEDLINE | ID: mdl-34399143

ABSTRACT

In both biologics quality control experiments and protein post-translational modification studies, the analytical system used is not supposed to bring any artefactual modifications which could impair the results. In this work, we investigated oxidation of methionine-containing peptides during reversed-phase (RP) chromatographic separation. We first used a synthetic methionine-containing peptide to evaluate this artefactual phenomenon and then considered more complex samples (i.e., plasma and HeLa protein digests). The methionine oxidation levels of the peptides were systematically assessed and compared for the long-term use of the analytical column, the sample trapping time, the gradient length, the sample load and the nature of the stationary phase (HSS T3 from Waters, YMC Triart C18 from YMC Europe GmbH and BEH130 C18 from Waters). In addition to the oxidation of methionine in solution, we observed on the HSS T3 and the BEH130 stationary phases an additional broad peak corresponding to an on-column oxidized species. Considering the HSS T3 phase, our results highlight that the on-column oxidation level significantly increases with the age of the analytical column and the gradient length and reaches 56 % when a 1-year-old column set is used with a 180 min-long LC method. These levels go to 0 % and 18 % for the YMC Triart C18 and the BEH130 C18 phases respectively. Interestingly, the on-column oxidation proportion decreases as the injected sample load increases suggesting the presence of a discrete number of oxidation sites within the stationary phase of the analytical column. Those findings observed in different laboratories using distinct set of columns, albeit to varying degrees, strengthen the need for a standard of methionine-containing peptide that could be used as a quality control to appraise the status of the liquid chromatographic columns.


Subject(s)
Chromatography, Reverse-Phase , Methionine , Peptides , Chromatography, Reverse-Phase/instrumentation , Chromatography, Reverse-Phase/standards , Methionine/metabolism , Oxidation-Reduction , Peptides/metabolism , Quality Control
2.
Eur J Pharm Sci ; 85: 94-105, 2016 Mar 31.
Article in English | MEDLINE | ID: mdl-26850682

ABSTRACT

The difficulty to find a relevant in vitro dissolution test to evaluate poorly soluble drugs is a well-known issue. One way to enhance their aqueous solubility is to formulate them as amorphous solid dispersions. In this study, three formulations containing itraconazole (ITZ), a model drug, were tested in seven different conditions (different USP apparatuses and different media). Two of the formulations were amorphous solid dispersions namely Sporanox®, the marketed product, and extrudates composed of Soluplus® and ITZ produced by hot melt extrusion; and the last one was pure crystalline ITZ capsules. After each test, a ranking of the formulations was established. Surprisingly, the two amorphous solid dispersions exhibited very different behavior depending primarily on the dissolution media. Indeed, the extrudates showed a better release profile than Sporanox® in non-sink and in biphasic conditions, whilst Sporanox® showed a higher release profile than the extrudates in sink and fasted simulated gastric conditions. The disintegration, dynamic light scattering and nuclear magnetic resonance results highlighted the presence of interaction between the surfactants and Soluplus®, which slowed down the erosion of the polymer matrix. Indeed, the negative charge of sodium dodecyl sulfate (SDS) and bile salts interacted with the surface of the extrudates that formed a barrier through which the water hardly diffused. Moreover, Soluplus® and SDS formed mixed micelles in solution in which ITZ interacts with SDS, but no longer with Soluplus®. Regarding the biphasic dissolution test, the interactions between the octanol dissolved in the aqueous media disrupted the polymer--ITZ system leading to a reduced release of ITZ from Sporanox®, whilst it had no influence on the extrudates. All together these results pointed out the difficulty of finding a suitable in vitro dissolution test due to interactions between the excipients that complicates the prediction of the behavior of these solid dispersions in vivo.


Subject(s)
Itraconazole/chemistry , Bile Acids and Salts/chemistry , Chemistry, Pharmaceutical/methods , Dynamic Light Scattering/methods , Excipients/chemistry , Magnetic Resonance Spectroscopy/methods , Polymers/chemistry , Sodium Dodecyl Sulfate/chemistry , Solubility , Surface-Active Agents/chemistry , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...