Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Cancer Res Clin Oncol ; 149(10): 7007-7015, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36856852

ABSTRACT

BACKGROUND: Intensity-modulated helical tomotherapy (HT) is a promising technique in preparation for bone marrow transplantation. Nevertheless, radiation-sensitive organs can be substantially compromised due to suboptimal delivery techniques of total body irradiation (TBI). To reduce the potential burden of radiation toxicity to organs at risk (OAR), high-quality coverage and homogeneity are essential. We investigated dosimetric data from kidney, lung and thorax, liver, and spleen in relation to peripheral blood kinetics. To further advance intensity-modulated total body irradiation (TBI), the potential for dose reduction to lung and kidney was considered in the analysis. PATIENTS AND METHODS: 46 patients undergoing TBI were included in this analysis, partially divided into dose groups (2, 4, 8, and 12 Gy). HT was performed using a rotating gantry to ensuring optimal reduction of radiation to the lungs and kidneys and to provide optimal coverage of other OAR. Common dosimetric parameters, such as D05, D95, and D50, were calculated and analysed. Leukocytes, neutrophils, platelets, creatinine, GFR, haemoglobin, overall survival, and graft-versus-host disease were related to the dosimetric evaluation using statistical tests. RESULTS: The mean D95 of the lung is 48.23%, less than half the prescribed and unreduced dose. The D95 of the chest is almost twice as high at 84.95%. Overall liver coverage values ranged from 96.79% for D95 to 107% for D05. The average dose sparing of all patients analysed resulted in an average D95 of 68.64% in the right kidney and 69.31% in the left kidney. Average D95 in the spleen was 94.28% and D05 was 107.05%. Homogeneity indexes ranged from 1.12 for liver to 2.28 for lung. The additional significance analyses conducted on these blood kinetics showed a significant difference between the 2 Gray group and the other three groups for leukocyte counts. Further statistical comparisons of the dose groups showed no significant differences. However, there were significant changes in the dose of OAR prescribed with dose sparing (e.g., lung vs. rib and kidney). CONCLUSION: Using intensity-modulated helical tomotherapy to deliver TBI is a feasible method in preparation for haematopoietic stem cell transplantation. Significant dose sparing in radiosensitive organs such as the lungs and kidneys is achievable with good overall quality of coverage. Peripheral blood kinetics support the positive impact of HT and its advantages strongly encourage its implementation within clinical routine.


Subject(s)
Hematopoietic Stem Cell Transplantation , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Whole-Body Irradiation/methods , Organs at Risk/radiation effects , Kinetics , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
2.
Eur J Med Res ; 27(1): 287, 2022 Dec 10.
Article in English | MEDLINE | ID: mdl-36496388

ABSTRACT

PURPOSE: Helical tomotherapy (HT) is a viable method for delivering total body irradiation (TBI) when preparing patients for allogenic stem cell or bone-marrow transplantation. TBI can be planned to reduce the amount of radiation delivered to organs at risk, such as the lungs, with the aim of decreasing toxicity. However, it is important for the ribcage to receive the prescribed radiation dose in preparation for bone-marrow transplantation. In this retrospective study, we analyzed radiation dose coverage of the lungs and ribcage in patients who underwent TBI delivered by HT to achieve lung dose sparing. METHODS: Thirty-five patients were included in the analysis and divided into three groups based on their prescribed radiation dose (4, 8, or 12 Gy). HT was performed using a rotating gantry to reduce radiation to the lungs. Dosimetric parameters for the lungs and ribcage as well as dose-volume histograms were calculated. RESULTS: The mean lung D95 was 60.97%, 54.77%, and 37.44% of the prescribed dose for patients receiving 4 Gy, 8 Gy, and 12 Gy, respectively. Ribcage coverage was most optimal for patients receiving 4 Gy, with a D95 of 91.27% and mean homogeneity index of 1.17, whereas patients receiving 12 Gy had a mean D95 of 78.65% and homogeneity index of 1.37, which is still within the range recommended by treatment guidelines. CONCLUSIONS: Using HT to achieve lung tissue sparing is a viable approach to minimizing pulmonic complications in patients undergoing TBI. As this planning adjustment does not compromise the dose and quality of coverage received by the ribcage, it is a feasible tool within conditioning regimens for allogeneic bone-marrow transplantation.


Subject(s)
Radiotherapy, Intensity-Modulated , Whole-Body Irradiation , Humans , Whole-Body Irradiation/methods , Radiotherapy Dosage , Retrospective Studies , Radiotherapy, Intensity-Modulated/methods , Lung
3.
Eur J Med Res ; 27(1): 265, 2022 Nov 24.
Article in English | MEDLINE | ID: mdl-36434707

ABSTRACT

BACKGROUND: Helical TomoTherapy® is widely used for total body irradiation as a component of conditioning regimens before allogeneic bone-marrow transplantation. However, this technique limits the maximum length of a planning target volume to 135 cm. Therefore, patients taller than 135 cm require two planning computed tomography scans and treatment plans. The junctional target between these two treatment plans is thus a critical region for treatment planning and delivery. Here, we compare radiation coverage of the junctional target between helical and static approaches to treatment planning and delivery to determine which approach allows high quality irradiation planning and provides more robustness against patient movement. METHODS: We retrospectively analyzed 10 patients who underwent total body irradiation using a static four-field box planning approach and nine patients who underwent total body irradiation using a helical planning approach. All patients were taller than 135 cm. The junctional target volume was divided into 10 slices of 1 cm thickness (JT1-JT10) for analysis. Dosimetric parameters and dose-volume histograms were compared to assess the quality of coverage of the junctional target between the helical and static planning approaches. RESULTS: The D50 for the total junctional target was slightly higher than the prescribed dose for both helical and static approaches, with a mean of 108.12% for the helical group and 107.81% for the static group. The mean D95 was 98.44% ± 4.19% for the helical group and 96.20% ± 4.59% for the static group. The mean homogeneity index covering the entire junctional target volume was 1.20 ± 0.04 for the helical group and 1.21 ± 0.05 for the static group. The mean homogeneity index ranged from 1.08 ± 0.01 in JT1 to 1.22 ± 0.06 in JT6 for the helical group and from 1.06 ± 0.02 in JT1 to 1.19 ± 0.05 in JT6 for the static group. There were no significant differences in parameters between helical and static groups. However, the static approach provided robustness against up to 30 mm of lateral movement of the patient. CONCLUSIONS: As long as TBI using helical TomoTherapy® is limited to a maximum length of 135 cm, the junctional target must be addressed during treatment planning. Our analysis shows that the static four-field box approach is viable and offers higher robustness against lateral movement of the patient than the helical approach.


Subject(s)
Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/methods , Whole-Body Irradiation , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Radiometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...